Pacific Energy Fusion Installation And Operating Instructions Manual

Manual is about: DIRECT VENT FREESTANDING STOVE

Summary of Fusion

  • Page 1

    081112-20 fusion_d1 5055.5161 installation and operating instructions safety notice: if this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re officials about restrictions and installation inspection requ...

  • Page 2: Contents

    2 fusion_d1 081112-20 please save these instructions note: we strongly recommend that smoke detectors be installed. If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be due to curing of stove paint or fumes caused by accidentally leav...

  • Page 3

    Fusion_d1 081112-20 3 safety and maintenance 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood should not be used, as it will reduce heat output, as well as contributing sign...

  • Page 4

    4 fusion_d1 081112-20 maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - sagging, placement, damage. Monthly...

  • Page 5

    Fusion_d1 081112-20 5 creosote formation and need for removal when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow burning fi re. As a result, creosot...

  • Page 6: Minimum

    6 fusion_d1 081112-20 double wall connector - mobile home double wall connector - residential single wall connector - residential 22 3/16” 13 1/2” 30 5/8” 19” 25 3/8” 25 3/8” 11 1/4” 11 1/4” 15 3/16” 6 1/2” 26 5/8” 15” 17” 11 1/2” 17” 20 3/16” 28 5/8” 4 1/4” 4 1/4” 18 3/8” 18 3/8” 8 1/4” 8 1/4” 22 3...

  • Page 7

    Fusion_d1 081112-20 7 procedure: caution: the structural integrity of the mo- bile home floor, wall and ceiling/roof must be maintained. Note: see "combustion air" section on page 9. 1. Position stove and fl oor protection with hole for combustion air in accordance with the clearances as stated on t...

  • Page 8

    8 fusion_d1 081112-20 fig. #3 chimney roof fl ashing storm collar * 4" diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside spark arres- tor rain cap radiation shield chimney connector chimney support 50 1/2" (1283 mm) minim...

  • Page 9

    Fusion_d1 081112-20 9 residential installation warning: under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may be fi red only after the following conditions have been met. * do not attempt to connect this heater to any air distribution duct. * the services...

  • Page 10

    10 fusion_d1 081112-20 canada only floor protector the stove may be installed on a combustible fl oor provided noncombustible ember protection is used. This protection must extend as follows: in canada: 18" (457 mm) on the fi ring side and 8" (203 mm) to the other sides. See figure #4, below. Combus...

  • Page 11

    Fusion_d1 081112-20 11 operation caution: never use gasoline, gasoline type lantern fuel, kero- sene, charcoal lighter fl uid or similar liquids to start or "freshen up" a fi re in this heater. Keep all such liquids well away from the heater while it is in use. Caution: hot while in operation. Keep ...

  • Page 12

    12 fusion_d1 081112-20 ash removal caution: ashes are to be removed only when the heater is cold. Whenever ashes get 3 to 4 inches deep in your fi rebox, and when fi re has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1" (25 mm) deep on the fi rebox bottom to help main...

  • Page 13

    Fusion_d1 081112-20 13 optional blower the optional blower kit (kit #wodc.Blow) is equipped with a three prong power cord and may be installed at any time. Fol- low installation instructions supplied with the kit. Route power supply cord away from heater. Electrical rating: 115 volts a.C.-1.02 amps....

  • Page 14

    14 fusion_d1 081112-20 appendix a troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney height and / or diamete...

  • Page 15

    Fusion_d1 081112-20 15 item/ article dimensions part number/ numÉro de piÈce a 1 1/2” x 4 1/2” x 1 1/4” (39 mm x 115 mm x 32 mm) 248.0 b 3” x 4 1/2” x 1 1/4” (77 mm x 115 mm x 32 mm) 247.0 c 4” x 4 1/2” x 1 1/4” (102 mm x 115 mm x 32 mm) 246.0 d 7 1/4” x 4 1/2” x 1 1/4” (184 mm x 115 mm x 32 mm) 245...

  • Page 16

    16 fusion_d1 081112-20 replacement parts (when ordering, include part number with description) item description part no. Item description part no. 1a.......... Side shield, left, black ......................... Fsnd.4640 .............. Stainless steel ...................................................

  • Page 17

    Fusion_d1 081112-20 17.

  • Page 18

    18 fusion_d1 081112-20

  • Page 19: Caution

    Fusion_d1 081112-20 19 label a. 19 in. / 483 mm 15 in. / 381 mm b. 13.5 in. / 343 mm 9.5 in. / 241 mm c. 11 .3 in. / 287 mm 11 .3 in. / 287 mm d. 27.5 in. / 699 mm 23.5 in. / 598 mm e. 19.1 in. /485 mm 15.1 in /384 mm f. 22.2 in. / 564 mm 22.2 in. / 564 mm a. 15 in. / 381 mm 15 in. / 381 mm b. 6.5 i...

  • Page 20

    Pacific energy fireplace products ltd. 2975 allenby rd., duncan, bc v9l 4t8 phone: 250-748-1184 web site: http://www.Pacifi cenergy.Net.