Pacific Energy Fusion Installation & Operation Manual

Manual is about: DIRECT VENT FREESTANDING STOVE

Summary of Fusion

  • Page 1

    Tested and listed to can/ulc s627 and ul 1482 meets the environmental protection agency's july 1990 particulate emission standards installation & operation guide design - d model fusion please save these instructions safety notice if this stove is not properly installed, a house fire may result. For...

  • Page 2: Contents

    2 fusion_d1 010604-16 contents safety and maintenance ................................................................................................... 3 creosote ............................................................................................................................. 4 formati...

  • Page 3

    010604-16 fusion_d1 3 please save these instructions note: we strongly recommend that smoke detectors be installed. If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be due to curing of stove paint or fumes caused by accidentally leav...

  • Page 4

    4 fusion_d1 010604-16 creosote formation and need for removal when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creo- sote. The creosote vapours condense in the relatively cool chimney flue of a slow burning fire. As a result, creosot...

  • Page 5: Minimum

    010604-16 fusion_d1 5 20" 11 1/2" 17" 17" 26" 15 6 1/2" 28" 30" 22" 9 1/2" 28" 18 13 1/2" 15" 17" 19" 8 1/4" 8 1/4" 4 1/4" 4 1/4" 18 22" 11 1/4" 11 1/4" 25" 22 1/4" 36 1/4" 23 1/2" 26 3/4" 8 3/8" 33 1/2" minimum clearance to combustibles fig. #1 double wall connector - residential single wall connec...

  • Page 6

    6 fusion_d1 010604-16 mobile home installation procedure: caution: the structural integrity of the mobile home floor, wall and ceiling/roof must be maintained. Note: see "combustion air" section onpage 9. 1. Position stove and floor protection with hole for combus- tion air in accordance with the cl...

  • Page 7

    010604-16 fusion_d1 7 fig. #2 chimney roof flashing storm collar * 4" diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside spark arrestor rain cap radiation shield chimney connector chimney support 50 1/2" (1283 mm) minimum ...

  • Page 8

    8 fusion_d1 010604-16 residential installation warning: under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may be fired only after the following conditions have been met. * do not attempt to connect this heater to any air distribution duct. * the services ...

  • Page 9

    010604-16 fusion_d1 9 canada only floor protector the stove may be installed on a combustible floor provided noncombustible ember protection is used. This protection must extend as follows: in canada: 18" (457 mm) on the firing side and 8" (203 mm) to the other sides. See figure #3, below. Combustio...

  • Page 10

    10 fusion_d1 010604-16 operation caution: never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or "freshen up" a fire in this heater. Keep all such liquids well away from the heater while it is in use. Caution: hot while in operation. Keep chil...

  • Page 11

    010604-16 fusion_d1 11 ash removal caution: ashes are to be removed only when the heater is cold. Whenever ashes get 3 to 4 inches deep in your firebox, and when fire has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1" (25 mm) deep on the firebox bottom to help maintai...

  • Page 12

    12 fusion_d1 010604-16 optional blower the optional blower kit (kit #wodc.Blow) is equipped with a three prong power cord and may be installed at any time. Follow installation instructions supplied with the kit. Route power supply cord away from heater. Electrical rating: 115 volts a.C.-1.02 amps. F...

  • Page 13

    010604-16 fusion_d1 13 troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney height and / or diameter - chimney...

  • Page 14

    14 fusion_d1 010604-16 replacement parts (when ordering, include part number with description) item description part no. Item description part no. 1a .......... Side shield, left, mocha ................... Fsnd.46025mca .............. Side shield, left, brushed nickel ..... Fsnd.46025bna 1b ...........

  • Page 15: Caution

    010604-16 fusion_d1 15 label made in canada certified for canada and u.S.A. Listed room heater, solid fuel type. Also for use in mobile homes tested to can/ulc s627-m93 and ul 1482-98 model series d: fusion 260504 5050.7623 fsnd-1 a. Sidewall to unit 19 in. / 483 mm 15 in. / 381 mm 15 in. / 381 mm 1...