    070905-28 fsga 5056.4221 installation and operating instructions fusion gas direct vent freestanding stove series a important: these instructions are to remain with the homeowner – do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. – w...

  • Page 2: Contents

    2 070905-28 fsga 5056.4221 caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 maintenance . . . . . . . . . . . . . . . . . . . ...

  • Page 3: Caution

    3 070905-28 fsga 5056.4221 for your safety do not install or operate your pacific energy heater without first reading and understanding this manual. Any installation or operational deviation from the following instructions voids the pacific energy warranty and may prove hazardous. This appliance and...

  • Page 4: Safety

    4 070905-28 fsga 5056.4221 • due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies. • children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. • young chil...

  • Page 5: Gas Supply

    5 070905-28 fsga 5056.4221 gas supply floor protection clearances attachment to floor in the state of massachusetts, only a licensed plumber and gas fitter may install this product. Correct gas line diameter must be used to assure proper operation. The gas control is equipped with a captured screw t...

  • Page 6: Top Or Rear Vent Conversion

    6 070905-28 fsga 5056.4221 top or rear vent conversion 1) remove the two screws securing the air deflector to the rear of the stove (fig. #3.01), remove the air deflector and store it in a safe place (fig. #3.02). 2) remove the two screws that secure the top plate in place (fig. #3.03). To remove th...

  • Page 7

    7 070905-28 fsga 5056.4221 important: take care not to damage the gaskets on the vent adapter and flue outlet cover plate during the procedure. Inspect the gaskets carefully before reinstalling, if the gasket on either piece is damaged, it will need to be replaced before continuing. 3) remove the fo...

  • Page 8

    8 070905-28 fsga 5056.4221 5) place the vent cover from step 3 over the top flue outlet (fig. #3.09) and use four screws to fasten it in place (fig. #3.10). 6) replace the top plate by hooking the front flange over the mounting brackets (fig. #3.11) pull it firmly towards the rear of the appliance a...

  • Page 9

    9 070905-28 fsga 5056.4221 7) place the air deflector back on the top of the appliance and align it so it is spaced evenly from either side. Fasten the air deflector to the rear bracket using two screws (fig. #3.13). 8) place the optional cast iron fusion gas trivet into the outlet of the air deflec...

  • Page 10: Venting

    10 070905-28 fsga 5056.4221 the fusion gas stove installation and venting must conform with local codes or, in the absence of local codes, to the current installation code, can/cga-b149.1 in canada or the current national fuel gas code, ansi z223.1 in the usa. Only qualified (licensed or trained) pe...

  • Page 11: Venting For Wall

    11 070905-28 fsga 5056.4221 venting for wall termination with vertical rise any combination of rise and run may be used but must be constrained to the boundaries of this chart. For each additional 90° elbow, reduce vent length by 2 feet. For each additional 45° elbow, reduce vent length by 1 foot. F...

  • Page 12: Roof

    12 070905-28 fsga 5056.4221 roof termination venting any combination of rise and run may be used but must be constrained to the bounaries of this chart. If more than 2 elbows are used, reduce horizontal run by 2 feet for each additional elbow. For optimum performance and flame appearance, keep the v...

  • Page 13: Vent Terminal

    13 070905-24 fsga 5056.4221 vent terminal clearances minimum clearances to the vent terminal must be maintained as shown in fig #8 and fig #9. Measure clearances to the nearest edge of termination hood. Note: vent terminal must not be recessed into a wall or siding. Follow vent terminal manufactur- ...

  • Page 14: Venting System Components

    14 070905-28 fsga 5056.4221 venting system components duravent gs secure vent galv. Black galv. Black 6" pipe length 908 908b sv 4 l6 sv 4 lb6 9" pipe length 907 907b 12" pipe length 906 906b sv 4 l12 sv 4 lb12 24" pipe length 904 904b sv 4 l24 sv 4 lb24 36" pipe length 903 903b sv 4 l36 sv 4 lb36 4...

  • Page 15: Removal Of Window Frame

    1) grasp the bottom of the door skin and pull sharply forward and up to unhook from the clip on the lower edge (fig. #10). 2) insert the handle provided into the latch mechanism located approximately two inches down from the top of the window frame (fig #11). 3) repeat on other side 4) swing the win...

  • Page 16: 70˚

    16 070905-28 fsga 5056.4221 this appliance has a built in manual damper that must be set dependant on the height of the vent. For recommended setting see fig #14. The damper only applies to top venting and is preset to 0º (fully opened) at the factory. To adjust vent damper: 1) if not already remove...

  • Page 17: Log Set Installation

    17 070905-28 fsga 5056.4221 log set installation the ceramic logs are durable and long lasting when installed properly. However, they are delicate and may be damaged easily if not handled with care. Unpack and inspect log set. There should be a total of 2 logs and one base ceramic. Gas and vent conn...

  • Page 18: Lighting Instructions

    18 070905-28 fsga 5056.4221 lighting instructions.

  • Page 19: First Fire

    19 070905-28 fsga 5056.4221 first fire manual operation when lit for the first time, the appli- ance will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ...

  • Page 20: Optional Remote Control

    20 070905-28 fsga 5056.4221 the fusion gas stove can be equipped with a thermostatic remote control. Once a pilot light has been established, and the gas control knob turned to the "on" position, the burner may be turned on or off simply with the remote control. The remote can be operated in three w...

  • Page 21: Optional Blower

    21 070905-28 fsga 5056.4221 optional blower the optional blower kit #fsga.Blow is equipped with a three prong power cord and may be installed at any time. Follow installation instructions supplied with the kit. Operation: the optional circulating air blower is either thermostatically or manually con...

  • Page 22: Propane Conversion

    22 070905-28 fsga 5056.4221 propane conversion 1) ensure that the burner, pilot and gas supply are turned off and the appliance is cool. 2) remove door skin by holding the base of the door and pulling up and outwards (fig. # 24). 3) remove window and frame by unlatch- ing the two latches, one each s...

  • Page 23: Conversion Label

    23 070905-28 fsga 5056.4221 9) remove the pilot hood by pulling it up and off the pilot assembly (fig. #30). 10) remove the pilot orifice with a 5/32" (4mm) hex key (fig. #31). 11) replace with pilot orifice supplied with this kit (marked 35) 12) reinstall the hood assembly. The pilot hood should sn...

  • Page 24: Body Replacement Parts

    24 070905-28 fsga 5056.4221 body replacement parts 1 30 9 19 12 15 6 37 5 11 49 48 35 50 29 16 38 20 2 21 8 32 50 14 24 26 13 27 18 17 22 31 7 22 41 39 34 42 40 3 25 44 45 46 10 28 43 33 23 47 36 4 item part number title qty 1 . . . . .2737. . . . . . . . . . . . . . . Flue cover . . . . . . . . . ....

  • Page 25: Burner Replacement Parts

    15 16 1 5 9 13 17 2 6 10 14 3 7 11 4 8 12 25 070905-28 fsga 5056.4221 burner replacement parts burner replacement parts item part number title qty 1 . . . . .5011.9 . . . . . . . . . . . . . Burner, dual fuel d0903 . . . . . . . . 1 2 . . . . .9807. . . . . . . . . . . . . . . Ceramic spacer bracket...

  • Page 26: Safety Label

    26 070905-28 fsga 5056.4221 safety label.

  • Page 27: Notes

    27 070905-28 fsga 5056.4221 notes.

  • Page 28: Www.Pacificenergy.Net

    Printed in canada 5056.4221 pacific energy fireplace products ltd. Www.Pacificenergy.Net toll free: 1-888-223-0088 2975 allenby road, duncan, bc canada v9l 6v8.