FOR YOUR SAFETY
Do not install or operate your Pacific
Energy heater without first reading
and understanding this manual. Any
installation or operational deviation
from the following instructions voids
the Pacific Energy Warranty and may
prove hazardous.
This appliance and its individual
shutoff valve must be disconnected
from gas supply piping system during
any pressure testing of that system at
test pressures in excess of 1/2 psig.
(3.5 kpa).
This appliance must be isolated from
the gas supply piping system by
closing its individual manual shutoff
valve during any pressure testing of
the gas supply piping system at test
pressures equal to or less than 1/2
psig. (3.5 kPa).
This appliance must not be
connected to a chimney flue serving
a separate solid-fuel burning
appliance.
If the optional blower is installed, this
appliance must be electrically ground-
ed in accordance with local codes or,
in the absence of local codes, with
the National Electrical Code,
ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1.
Important: When lit for the first time, the appliance will emit a slight
odour for a couple of hours. This is due to the curing of paints, sealants
and lubricants used in the manufacturing process. This condition is
temporary. Open doors and windows to ventilate area. If optional fan kit
has been installed, place fan in the "OFF" position. Smoke and fumes
caused by the curing process may cause discomfort to some
individuals.
It is normal for fireplaces fabricated of steel to give off some expansion
and/or contraction noises during the start up or cool down cycle. Similar
noises are found with your furnace heat exchanger or cook stove oven.
Caution
Fig. #1
7 5/8”
34”
18 5/8”
12 9/16”
26 7/16”
21”
Stove Dimensions
Center of top flue outlet
Center of rear
flue outlet