Pacific Energy Fusion Installation And Operating Instructions Manual - Gas Supply
5
070905-28
FSGA 5056.4221
Gas Supply
Floor Protection
Clearances
Attachment
to Floor
In the state of Massachusetts, only a
licensed plumber and gas fitter may
install this product. Correct gas line
diameter must be used to assure
proper operation.
The gas control is equipped with a
captured screw type pressure test
point, therefore it is not necessary to
provide a 1/8 inch N.P.T. plugged
tapping pressure test port for
checking gas pressure immediately
upstream of the gas supply
connection to the appliance.
The gas valve inlet accepts a 3/8"
N.P.T. fitting.
Mobile Home installations require that
the appliance be firmly attached to
the structure. Once the appliance is in
its final location, secure the unit in
place through holes in the pedestal
base. The holes are located on the
left and right hand side of the base.
The Fusion Gas stove may be
installed directly on a combustible
floor. If the appliance is to be installed
directly on carpeting, combustible
floor tile or other combustible material
other than wood flooring, the
appliance shall be installed on a
metal or wood panel extending the
full width and depth of the unit.
The minimum clearances from the
appliance to combustibles are shown
on Fig. #3. Adequate clearances
around air openings are required.
Sidewall to Appliance
6 in
(152 mm)
Rearwall to Appliance
1 in
(25 mm)
Corner to Appliance
1 in
(25 mm)
Alcove Sidewall to Appliance
6 in
(152 mm)
Alcove minimum width
33 in
(838 mm)
Alcove maximum depth
48 in
(1219 mm)
Alcove minimum height
46 in
(1168 mm)
Minimum Clearances to Combustibles
Correct gas pressure requirements
Natural Gas
Propane
Min. Pressure
5.0” WC
11.5” WC
(For purpose of
input adjustment)
Max. Pressure
13.9” WC
13.9” WC
Manifold Pressure
Maximum
3.8” WC
10.5” WC
Minimum
0.7” WC
1.6” WC
13 3/4”
1”
1”
Fig. #3
Caution:
The gas line should be installed
by a qualified service person in
accordance with all building
codes. Consult local and/or
national building codes before
proceeding.
1”
8 5/8”
16 1/2”
6”
8 5/8”
1”
6”
ALCOVE HEIGHT
61” MINIMUM
6”
48”