Blower Operation
The Insert comes equipped with circulating air blowers. The blower system is
thermostatically controlled for automatic operation, as well manually with a convenient
bypass switch.
Automatic: To operate the blower automatically, push the rocker switch to the “0” or
AUTO position and set the fan speed control to a desired setting.
This will allow the blower to turn on automatically once the Insert has come
up to operating temperature. It will also shut the blower off after the fire has
gone out and the appliance cooled to below a useful heat output range. On
and Off times will vary with installation and usage of appliance.
Manual: To manually operate the blower, push the rocker switch to the “1” or MANUAL
position and set the fan speed control to a desired setting.
This will bypass the temperature switch and allow full control of the blower.
Suggested settings:
- Combustion air control setting of "Low"(all the way to the right), operate blower
speed control on “Low”.
- Combustion air control greater than "Low", operate blower speed control at desired
setting. o “High”
Electrical Supply
Circulating air blower electrical rating: 230V, 50 Hz. 1A.
For your protection against shock hazard, use only a properly grounded outlet that will
accept a three-pronged plug. Do not cut or remove the grounding.
All electrical connections to and within an appliance shall be in accordance with the requirments
od AS/NZS 3000, AS/NZS 3100 or ER 93 and the regulatory auhtority as appropriate.
L2 (black)
G (green)
L1 (white)
Speed
Control
Blowers
Thermo
Switch
By-pass
Rocker Switch
For your protection against
shock hazard, use only a properly
grounded outlet that will accept a
grounded plug
Fig. # 8