280416-24 summit-b 5055.3252 installation and operating instructions safety notice if this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirem...
2 summit-b 280416-24 contents safety and maintenance .............................................................. 3 maintenance checks ................................................................... 4 chimney smoke and creosote formation ............................................. 5 chimney ...
Summit-b 280416-24 3 safety and maintenance 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood should not be used, as it will reduce heat output, as well as contributing signi...
4 maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - sagging, placement, damage. Monthly - brick rail tabs a...
5 chimney smoke and creosote formation when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney flue of a slow burning fire. As a result, creosote residue accumulates on ...
6 summit-b 280416-24 double wall connector - residential double wall connector - mobile home single wall connector - residential fig. #2 minimum clearance to combustibles alcove: min. Height 7'(2.1m) max. Depth 4'(1.2m) optional ash cleanout system 1) remove nuts holding the ash system hole cover an...
7 procedure: caution: the structural integrity of the mobile home floor, wall and ceiling/roof must be maintained. The space heater is to be connected to a factory- built chimney conforming to can/ulc-s629 standard for 650c factory-built chimneys. Note: see "combustion air" section on page 9. 1. Pos...
8 fig. #3 chimney roof flashing storm collar * 4"(102mm) diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside spark arres- tor rain cap radiation shield chimney connector chimney support 54" (1372 mm) minimum attachment to f...
9 residential installation warning: under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may be fired only after the following conditions have been met. * do not attempt to connect this heater to any air distribution duct. * outside combustion air or fresh a...
10 canada only floor protector the stove may be installed on a combustible floor provided noncombustible ember protection is used. This protection must extend as follows: in canada: 18" (457 mm) on the firing side and 8" (203 mm) to the other sides. See figure #4, below. Combustion air intake or com...
11 operation caution: never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or "freshen up" a fire in this heater. Keep all such liquids well away from the heater while it is in use. Caution: hot while in operation. Keep children, clothing and f...
12 do not burn with ash dump door open. Doing so will create a hazardous condition. Always leave about 1"(25mm) of ash when cleaning. Disposal of ashes ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed outside on a non- combustible f...
13 troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney height and / or diameter - chimney plugged or restrict...
14 operating tips 1. Always use dry, seasoned firewood, up to 18"(457mm) long. Load wood endwise, a mixture of large and small pieces, on top of a good ash base (1"(25mm) minimum). 2. Operate on a medium to high setting, for up to 1 hour from cold start. After the initial warm up period, refuel and ...
15 replacement parts item description part no. Item description part no. 1............Side shield, left or right...................... Summ.3201 2............Rear deflector ......................................Summ.3203 3............Cast ash lip ...................................Alip.503743mb 4......
16 replacement parts - summit classic item description part no. Item description part no. 1............Top panel .......................................Suca.3251xxa 2............Screen trivet ..................................... Clad.Ctxxa 3............Side shield .....................................
17 super 27 and pacific summit note: optional ash dump kit should be installed prior to pedestal or leg kit assembly. Required tools: 1 - claw hammer, 1 - 3/4" wrench, and 1- 7/16" wrench required: pedestal kit leg adapter 1 pedestal base 1 ash drawer enclosure 1 front cover (attached) 1 front cover...
18 item size part number a 1 1/2” x 4 1/2” x 1 1/4” (39 mm x 115 mm x 32 mm) 248.001 b 4” x 4 1/2” x 1 1/4” (102 mm x 115 mm x 32 mm) 246.001 c 7 1/4” x 4 1/2” x 1 1/4” (184 mm x 115 mm x 32 mm) 245.001 d 9” x 4 1/2” x 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 e 9” x 4 1/2” (cut) x 1 1/4” (230 mm x 1...
19 warranty information pacific energy limited lifetime warranty wood products pacific energy extends the following warranty coverage to the original registered purchaser of the product: ltd lifetime coverage (10 years) limited lifetime coverage is extended to the following components (parts only) p...
20 summit-b 280416-24.
21 summit-b 280416-24.
22 summit-b 280416-24.
Summit-b 280416-24 23 label label location a. 14 in. / 356 mm 14 in. / 356 mm b. 9 in. / 229 mm 9 in. / 229 mm c. 6 in. / 152 mm 6 in. / 152 mm summit d. 23.8 in. / 605 mm 23.8 in. / 605 mm e. *14.5 in. /368 mm *14.5 in. /368 mm f. *17.3 in. / 439 mm *17.3 in. /439 mm alderlea t6 d. 25.6 in. / 650 m...
Pacific energy fireplace products ltd. 2975 allenby rd., duncan, b.C. V9l 6v8 for technical support, please contact your retailer. Web site: http://www.Pacificenergy.Net printed in canada.