Pacific Energy SUMMIT Installation And Operation Instructions Manual

Summary of SUMMIT

  • Page 1

    250314-24 sinc 5055.5112 safety notice if this stove is not properly installed, a house fi re may result. For your safety, follow the installation directions. Consult local building or officials about restrictions and installation inspection requirements in your area. Important: these instructions a...

  • Page 2: Contents

    2 sinc 250314-24 contents safety ............................................................................................ 3 clearances ................................................................................... 3 masonry or factory built fireplace ...........................................

  • Page 3

    Sinc 250314-24 3 3 15” 22 1/4” minimum clearances to combustibles (measured from insert body) adjacent sidewall ..........................8 in. (203 mm.) mantel .......................................... 15 in. (381 mm.) top facing ................................... 15 in. (381 mm.) side facing (1....

  • Page 4

    4 sinc 250314-24 maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - sagging, placement, damage. Monthly - br...

  • Page 5

    Sinc 250314-24 5 16” non-combustible fi replace hearth 28” 23 1/8” 18” 8” 8” fireplace hearth requirements: (measured without the insert) the non-combustible fi replace hearth must be raised 3” above an adjacent combustible fl oor and extend 16” in front and 8” beyond each side of the existing fi re...

  • Page 6

    6 sinc 250314-24 dimensions 40 7/8” 23 5/16” 25 3/8” 27 9/16” b a 28 7/8” 18” 10 7/8” 21” 6 5/8” 12 1/4” 22 15/16” 9 1/8” mantel clearances a 15” b 15” mantel clearance chart a b 12" 4" reg. Surround a 48 3/4” b 32 1/16” surround dimensions.

  • Page 7

    Sinc 250314-24 7 installation your insert is designed to be installed into a masonry or fac- tory built zero-clearance fi replace. The masonry fi replace must be built according to the requirements of the standard of chimneys, fireplaces, vents and solid fuel burning ap- pliances, n.F.P.A. 211 (late...

  • Page 8

    8 sinc 250314-24 full flue liner - (required in canada) 1) measure the chimney height from the top of the existing fl ue to the fl oor of the hearth. This will allow extra length of liner for fl ashing and rain cap. 2) feed the stainless steel liner from top of the chimney, through the damper area a...

  • Page 9

    Sinc 250314-24 9 into a factory built fireplace your insert may be installed into a factory built fi replace (size permitting) with the following requirements: 1) inspect your fi replace for damage or other physical de- fects. The fi replace must be in good working condition. If in doubt about its c...

  • Page 10

    10 sinc 250314-24 surround assembly and installation 1) lay part a, b and c face down on a fl at, non-marring surface. Fasten together with 1/4" x 1/2" bolts and nuts provided through holes at points “d” (fig. #8). 2) lift the surround assembly to the upright position and make sure the front face is...

  • Page 11

    Sinc 250314-24 11 fan speed controller relocation the fan speed controller is factory installed under the ash lip on the right hand side. If required, it can be relocated to the left side by following the instructions below. To make this as easy as possible, it is suggested that this be done prior t...

  • Page 12

    12 sinc 250314-24 6) route cable from speed control to fan and reattach wire support tabs on the underside of the ash lip. Note wire positions. (fig.18 & fig.19) 7) remove thermal switch from right hand fan mounting bracket and relocate to left hand fan mounting bracket. Fig #20&21 8) reconnect the ...

  • Page 13

    Sinc 250314-24 13 operation wood selection this heater is designed to burn natural wood only. Higher efficiency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or too green or freshly cut hardwoods. Wood should be properly air dried (seasoned)...

  • Page 14

    14 sinc 250314-24 more wood, more heat seasoned wood has approximately 7500 btu’s per pound. If you put 10 pounds of wood in your stove for an eight hour burn the wood will be producing 9375 btu’s per hour. (7500 btu x 10 lbs / 8 hrs. = 9375 btu’s per hr.). If you put 20 lbs of wood in your stove fo...

  • Page 15

    Sinc 250314-24 15 in case of a chimney fire 1. Prepare to evacuate to ensure everyone’s safety. Have a well understood plan of action for evacuation. Have a place outside where everyone is to meet. 2. Close air inlets on stove. 3. Call local fi re department. Have a fi re extinguisher handy. Contact...

  • Page 16

    16 sinc 250314-24 7. Do not store wood within heater installation clearances, or within the space required for fuel loading and ash removal. Keep the area around the heater clean and free of all loose combustibles, furniture, newspapers, etc. 8. If gold door requires cleaning, use mild soap and wate...

  • Page 17

    Sinc 250314-24 17 appendix a understanding & operating your pacifi c energy stove the pacifi c energy line of woodstoves is a culmination of years of research and development. Designed to be efficient, clean-burning and user-friendly, this heater will give you years of warm service. However, a knowl...

  • Page 18

    18 sinc 250314-24 troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney height and / or diameter - chimney plug...

  • Page 19: Summit Insert Wood Stove

    Sinc 250314-24 19 item size part number a 1 1/2” x 4 1/2” x 1 1/4” (39 mm x 115 mm x 32 mm) 248.001 b 4” x 4 1/2” x 1 1/4” (102 mm x 115 mm x 32 mm) 246.001 c 7 1/4” x 4 1/2” x 1 1/4” (184 mm x 115 mm x 32 mm) 245.001 d 9” x 4 1/2” x 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 e 9” x 4 1/2” (cut) x 1 1...

  • Page 20

    20 sinc 250314-24 1......Bay top (c/w washers and nuts) ................Sins.50374524-c 2......Casing top, back ............................................................. 3502 3......Casing top, front ........................................................ 3502.51 4......Casing back................

  • Page 21

    Sinc 250314-24 21 fig. # 25.

  • Page 22

    22 sinc 250314-24 notes:.

  • Page 23: Caution

    Sinc 250314-24 23 label minimum clearance to combustibles (measured from insert body) dÉgagement minimum aux combustibles a) adjacent sidewall/ 203 mm / 8 in paroi latÉrale adjacente b) mantel 381 mm / 15in c) top facing/ 381 mm / 15in revÊtement supÉrieur d) side facing/ 203 mm / 8 in revÊtement la...

  • Page 24

    Pacific energy fireplace products ltd. Phone: 1-250-748-1184 www.Pacifi cenergy.Net 2975 allenby rd., duncan, b.C. V9l 6v8 printed in canada.