Pacific Energy SUPER 27 SPECTRUM Installation And Operating Instructions Manual

Other manuals for SUPER 27 SPECTRUM: Installation & Operation Manual, Operating Instructions Manual
Manual is about: Wood Stoves

Summary of SUPER 27 SPECTRUM

  • Page 1

    071111-20 super-sd1 5055.201 installation a n d o p e r at i n g instructions safety notice if this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspectio...

  • Page 2: Contents

    2 super-sd1 071111-20 please save these instructions note: we strongly recommend that smoke detectors be installed. If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be due to curing of stove paint or fumes caused by accidentally leav...

  • Page 3

    071111-20 super-sd1 3 safety and maintenance 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary to burn wet...

  • Page 4

    4 super-sd1 071111-20 creosote formation and need for removal when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow burning fi re. As a result, creosot...

  • Page 5: - Super 27 Only -

    071111-20 super-sd1 5 super 27 - pedestal model spectrum super 27 - leg model spectrum classic 2) secure in place with 1" x 1/2" bolts previously re- moved. 3) carefully place the unit in the upright position. Leg kit 1) with the unit on its back, align the ash drawer enclo- sure mounting holes (rem...

  • Page 6: Minimum

    6 super-sd1 071111-20 22" 12" 18" 30" 25" 11" 11" 20" 16" 26" 14" 15" 5" 10" 16" 18" 28" 4" 4" 8" 28" 18" 16" 8" 22" 8" minimum clearance to combustibles procedure: caution: the structural integrity of the mobile home floor, wall and ceiling/roof must be maintained. Note: see "combustion air" sectio...

  • Page 7

    071111-20 super-sd1 7 fig. #2 chimney roof fl ashing storm collar * 4" diameter air inlet with rodent screen * if the crawl space is well ventilated spark arres- tor rain cap radiation shield chimney con- chimney sup- 56" (1422 mm) minimum minimum 7' (2.1m.) ceiling height attachment to fl oor for m...

  • Page 8

    8 super-sd1 071111-20 residential installation warning: under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may be fi red only after the following conditions have been met. * do not attempt to connect this heater to any air distribution duct. * the services...

  • Page 9

    071111-20 super-sd1 9 16" [406mm] 8" [203mm] 8" [203mm] canada only floor protector the stove may be installed on a combustible fl oor provided noncombustible ember protection is used. This protection must extend as follows: in canada: 18" (457 mm) on the fi ring side and 8" (203 mm) to the other si...

  • Page 10

    10 super-sd1 071111-20 operation caution: never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fl uid or similar liquids to start or "freshen up" a fi re in this heater. Keep all such liquids well away from the heater while it is in use. Caution: hot while in operation. Keep ch...

  • Page 11

    071111-20 super-sd1 11 ash removal caution: ashes are to be removed only when the heater is cold. Whenever ashes get 3 to 4 inches deep in your fi rebox, and when fi re has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1" (25 mm) deep on the fi rebox bottom to help main...

  • Page 12

    12 super-sd1 071111-20 optional blower the optional blower kit (kit #wodc.Blow) is equipped with a three prong power cord and may be installed at any time. Follow installation instructions supplied with the kit. Route power supply cord away from heater. Electrical rating: 115 volts a.C.-1.02 amps. F...

  • Page 13

    071111-20 super-sd1 13 troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney height and / or diameter - chimney...

  • Page 14

    14 super-sd1 071111-20 replacement parts - super 27 (when ordering, include part number with description) item description part no. Item description part no. 1............ Side shield, left or right.................... Supd.4302 2............ Rear defl ector ...................................... Ss...

  • Page 15

    071111-20 super-sd1 15 2 1 6 27 20 29 8 13 11 12 24 24 25 21 9 10 7 1 19 22 31 23 3 4 28 12 11 31 18 30 5 15b 15a 16 17 16 16 14 replacement parts - spectrum and spectrum classic (when ordering, include part number with description) item description part no. Item description part no. 1............ S...

  • Page 16

    16 super-sd1 071111-20 operating tips 1. Always use dry, seasoned fi rewood, up to 18" long. Load wood endwise, a mixture of large and small pieces, on top of a good ash base (1" minimum). 2. Operate on a medium to high setting, for up to 1 hour from cold start. After the initial warm up period, ref...

  • Page 17: Super 27 and Pacifi C

    071111-20 super-sd1 17 super 27 and pacifi c note: optional ash dump kit should be installed prior to pedestal or leg kit assembly. Required: pedestal kit leg adapter 1 pedestal base 1 ash drawer enclosure 1 front cover (attached) 1 front cover (attached) 4 1/2" washers with leg set 4 legs crate rem...

  • Page 18

    18 super-sd1 071111-20 notes.

  • Page 19: Caution

    071111-20 super-sd1 19 label certified for canada and u.S.A. Listed room heater, solid fuel type. Also for use in mobile homes tested to can/ulc s627-m93 and ul 1482-98 alderlea t5 model series d: super 27 spectrum classic wn# 16408 250509 5050.75 sup1-a2 a. Sidewall to unit 18 in. / 455 mm 14 in. /...

  • Page 20

    Pacific energy fireplace products ltd. 2975 allenby rd., duncan, b.C. V9l 6v8 phone: 250-748-1184 web site: http://www.Pacifi cenergy.Net printed in canada.