Pacific Energy SPECTRUM Operating Instructions Manual

Summary of SPECTRUM

  • Page 1

    230514-20 super-sd1 5055.201as installation a n d o p e r at i n g instructions safety notice if this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspect...

  • Page 2: Contents

    2 super-sd1 230514-20 please save these instructions note: we strongly recommend that smoke detectors be installed. If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be due to curing of stove paint or fumes caused by accidentally leav...

  • Page 3

    230514-20 super-sd1 3 safety and maintenance 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary to burn wet...

  • Page 4

    4 super-sd1 230514-20 maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - sagging, placement, damage. Monthly...

  • Page 5

    230514-20 super-sd1 5 creosote formation and need for removal when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow burning fi re. As a result, creosot...

  • Page 6: - Super 27 Only -

    6 super-sd1 230514-20 610mm 740mm 702mm 610mm 711mm 600mm 254mm 740mm 721mm 606mm 254mm 600mm 699mm 737mm 699mm 711mm 600mm 254mm 737mm 718mm 606mm 254mm 600mm 699mm super 27 - pedestal model spectrum super 27 - leg model spectrum classic leg kit 1) with the unit on its back, align the ash drawer en...

  • Page 7

    230514-20 super-sd1 7 installation warning: under no circumstances is this heater to be installed in a make- shift or "temporary" manner. It may be fi red only after the stove is installed properly. Do not attempt to connect this heater to any air distribution duct. Outside combustion air or fresh a...

  • Page 8

    8 super-sd1 230514-20 559mm 350mm 375mm 762mm 893mm 275mm 275mm 559mm 100mm 375mm 762mm 787mm 200mm 200mm minimum clearance to combustibles fig. #2 single wall connector fig. #3 floor protector the stove may be installed on a combustible fl oor provided ember protection made from a 6mm thick non-com...

  • Page 9

    230514-20 super-sd1 9 chimney and connector warning: install chimney and all components of chimney system according to chimney manufacturer’s instructions. Connect to a listed chimney complying with the requirements of as/nzs2918/2001 and a chimney suitable for use with solid fuel that is lined and ...

  • Page 10

    10 super-sd1 230514-20 item/ article dimensions part number/ numÉro de piÈce a (39 mm x 115 mm x 32 mm) 248.0 b (77 mm x 115 mm x 32 mm) 247.0 c (102 mm x 115 mm x 32 mm) 246.0 d (184 mm x 115 mm x 32 mm) 245.0 e (230 mm x 115 mm x 32 mm) 5096.99 super 27, spectrum, spectrum classic, and fusion fire...

  • Page 11

    230514-20 super-sd1 11 combustion air intake or combustion air can be supplied to the stove in one of two ways. Consult your local building code or installation code for solid-fuel-burning appliances and equipment before proceeding. 1. Outside air supply - (necessary for mobile home installation, op...

  • Page 12

    12 super-sd1 230514-20 operation caution: never use gasoline, gasoline type lantern fuel, kero- sene, charcoal lighter fl uid or similar liquids to start or “freshen up” a fi re in this heater. Keep all such liquids well away from the heater while it is in use. Caution: hot while in operation. Keep ...

  • Page 13

    230514-20 super-sd1 13 warning: always keep loading door closed when burning. This heater is not designed for open door burning. Warning: no alteration or modifi cation of the com- bustion air control assembly is permitted. Any tamper- ing will void warranty and could be very hazardous. Warning: do ...

  • Page 14

    14 super-sd1 230514-20 troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney height and / or diameter - chimney...

  • Page 15

    230514-20 super-sd1 15 replacement parts - super 27 (when ordering, include part number with description) item description part no. Item description part no. 1............ Side shield, left or right.................... Supd.4302 2............ Rear defl ector ...................................... Ss...

  • Page 16

    16 super-sd1 230514-20 2 1 6 27 20 29 8 13 11 12 24 24 25 21 9 10 7 1 19 22 31 23 3 4 28 12 11 31 18 30 5 15b 15a 16 17 16 16 14 replacement parts - spectrum and spectrum classic (when ordering, include part number with description) item description part no. Item description part no. 1............ S...

  • Page 17

    230514-20 super-sd1 17 operating tips 1. Always use dry, seasoned fi rewood, up to 457mm long. Load wood endwise, a mixture of large and small pieces, on top of a good ash base (25mm minimum). 2. Operate on a medium to high setting, for up to 1 hour from cold start. After the initial warm up period,...

  • Page 18

    18 super-sd1 230514-20

  • Page 19: Series:  D

    230514-20 super-sd1 19 compliance plate 300114 5050.42as model: alderlea t5, super 27, spectrum, spectrum classic, fusion, sted d1 series: d type: freestanding made in canada maximum average heat output burning hardwood - 10.0 kw overall average efficiency burning hardwood - 67% when tested in accor...

  • Page 20

    Pacific energy fireplace products ltd. 2975 allenby rd., duncan, b.C. V9l 6v8 phone: 250-748-1184 web site: http://www.Pacifi cenergy.Net printed in canada.