Pacific Energy SPECTRUM Installation And Operating Instructions Manual

Summary of SPECTRUM

  • Page 1

    300913-24 super-sd1 5055.201 installation a n d o p e r at i n g instructions safety notice if this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspectio...

  • Page 2: Contents

    2 super-sd1 300913-24 please save these instructions note: we strongly recommend that smoke detectors be installed. If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be due to curing of stove paint or fumes caused by accidentally leav...

  • Page 3

    300913-24 super-sd1 3 safety and maintenance 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary to burn wet...

  • Page 4

    4 super-sd1 300913-24 maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - sagging, placement, damage. Monthly...

  • Page 5

    300913-24 super-sd1 5 creosote formation and need for removal when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow burning fi re. As a result, creosot...

  • Page 6: - Super 27 Only -

    6 super-sd1 300913-24 super 27 - pedestal model spectrum super 27 - leg model spectrum classic 2) secure in place with 1" x 1/2" bolts previously re- moved. 3) carefully place the unit in the upright position. Leg kit 1) with the unit on its back, align the ash drawer enclo- sure mounting holes (rem...

  • Page 7: Minimum

    300913-24 super-sd1 7 22" 12" 18" 30" 25" 11" 11" 20" 16" 26" 14" 15" 5" 10" 16" 18" 28" 4" 4" 8" 28" 18" 16" 8" 22" 8" minimum clearance to combustibles procedure: caution: the structural integrity of the mobile home floor, wall and ceiling/roof must be maintained. Note: see "combustion air" sectio...

  • Page 8

    8 super-sd1 300913-24 fig. #2 chimney roof fl ashing storm collar * 4" diameter air inlet with rodent screen * if the crawl space is well ventilated spark arres- tor rain cap radiation shield chimney con- chimney sup- 56" (1422 mm) minimum minimum 7' (2.1m.) ceiling height attachment to fl oor for m...

  • Page 9

    300913-24 super-sd1 9 residential installation warning: under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may be fi red only after the following conditions have been met. * do not attempt to connect this heater to any air distribution duct. * the services...

  • Page 10

    10 super-sd1 300913-24 16" [406mm] 8" [203mm] 8" [203mm] canada only floor protector the stove may be installed on a combustible fl oor provided noncombustible ember protection is used. This protection must extend as follows: in canada: 18" (457 mm) on the fi ring side and 8" (203 mm) to the other s...

  • Page 11

    300913-24 super-sd1 11 operation caution: never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fl uid or similar liquids to start or "freshen up" a fi re in this heater. Keep all such liquids well away from the heater while it is in use. Caution: hot while in operation. Keep ch...

  • Page 12

    12 super-sd1 300913-24 ash removal caution: ashes are to be removed only when the heater is cold. Whenever ashes get 3 to 4 inches deep in your fi rebox, and when fi re has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1" (25 mm) deep on the fi rebox bottom to help main...

  • Page 13

    300913-24 super-sd1 13 optional blower the optional blower kit (kit #wodc.Blow) is equipped with a three prong power cord and may be installed at any time. Follow installation instructions supplied with the kit. Route power supply cord away from heater. Electrical rating: 115 volts a.C.-1.02 amps. F...

  • Page 14

    14 super-sd1 300913-24 troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney height and / or diameter - chimney...

  • Page 15

    300913-24 super-sd1 15 replacement parts - super 27 (when ordering, include part number with description) item description part no. Item description part no. 1............ Side shield, left or right.................... Supd.4302 2............ Rear defl ector ...................................... Ss...

  • Page 16

    16 super-sd1 300913-24 2 1 6 27 20 29 8 13 11 12 24 24 25 21 9 10 7 1 19 22 31 23 3 4 28 12 11 31 18 30 5 15b 15a 16 17 16 16 14 replacement parts - spectrum and spectrum classic (when ordering, include part number with description) item description part no. Item description part no. 1............ S...

  • Page 17

    300913-24 super-sd1 17 operating tips 1. Always use dry, seasoned fi rewood, up to 18" long. Load wood endwise, a mixture of large and small pieces, on top of a good ash base (1" minimum). 2. Operate on a medium to high setting, for up to 1 hour from cold start. After the initial warm up period, ref...

  • Page 18: Super 27 and Pacifi C

    18 super-sd1 300913-24 super 27 and pacifi c note: optional ash dump kit should be installed prior to pedestal or leg kit assembly. Required tools: 1 - claw hammer, 1 - 3/4" wrench, and 1- 7/16" wrench required: pedestal kit leg adapter 1 pedestal base 1 ash drawer enclosure 1 front cover (attached)...

  • Page 19

    300913-24 super-sd1 19 item/ article dimensions part number/ numÉro de piÈce a 1 1/2” x 4 1/2” x 1 1/4” (39 mm x 115 mm x 32 mm) 248.0 b 3” x 4 1/2” x 1 1/4” (77 mm x 115 mm x 32 mm) 247.0 c 4” x 4 1/2” x 1 1/4” (102 mm x 115 mm x 32 mm) 246.0 d 7 1/4” x 4 1/2” x 1 1/4” (184 mm x 115 mm x 32 mm) 245...

  • Page 20

    20 super-sd1 300913-24.

  • Page 21

    300913-24 super-sd1 21.

  • Page 22

    22 super-sd1 300913-24.

  • Page 23: Caution

    300913-24 super-sd1 23 label a. 18 in. / 455 mm 14 in. / 356 mm b. 12 in. / 305 mm 8 in. / 200 mm c. 11 in. / 280 mm 11 in. / 280 mm d. 27 in. / 685 mm 23 in. / 585 mm e. 19 in. / 485 mm 15 in. / 380 mm f. 22 in. / 560 mm 22 in. / 560 mm a. 14 in. / 356 mm 14 in. / 356 mm b. 5 in. / 127 mm 5 in. / 1...

  • Page 24

    Pacific energy fireplace products ltd. 2975 allenby rd., duncan, b.C. V9l 6v8 phone: 250-748-1184 web site: http://www.Pacifi cenergy.Net printed in canada.