Palazzetti Ecofire Adagio Installation, User And Maintenance Manual - page 24
50/136
cod. 00 477 2290 - 07/2013 - Palazzetti - PN - Italy
USE AND MAINTENANCE
a) Use the arrow buttons
to go to the setup menu
and then press
;
b) Use the
button to select the password “7” and then press
'
c) Select submenu
[7]
!
.
d) Set one of the following values using the
buttons:
Eco
“Eco Mode” function enabled
Off
“Eco Mode” function disabled
e) Press
10.3 RESTART DELTA FUNCTION
The Restart delta is the number of degrees centigrade below the switch-off temperature at which the stove
switches on again automatically. For example, if the stove is set to switch off at 20°C (Eco Mode active) and
“Restart delta” is set to 4°C, the stove will switch on again when the temperature measured is less than or equal
to 16°C.
To set the restart delta value:
a) Use the arrow buttons
to go to the setup menu
and then press
;
b) Use the
button to select the password “7” and then press
';
c) Select submenu
[8]
and press
'
d) +¢'
and
buttons (
0,5 ... 5,0°C
);
e) Press the
!
10.4 AUTONOMY FUNCTION
+ ! !
with pellets. Use the arrow buttons to move to the
symbol and display the estimated operating hours before
¢+
on the stove.
The estimated values are quite reliable, as long “
FULL
%¢
completely. “Lo” indicates the reserve fuel level.
10.5 REFILL FUNCTION
+!¢
In this way, the stove can estimate, based on the operating parameters, how many hours of autonomy remain
!¢
a) Use the arrow buttons
to move to the fuel icon
and press ente
.
b) Use the
buttons to select “
FULL
” and press enter
.
To disable this function, select “
OFF
” instead of “
FULL
”.
10.6 RESTARTING AFTER A POWER FAILURE
In the event of power failures, the stove will switch back on automatically, checking the safety conditions, when
power returns.
10.7 'w|#{_+bj]|=w]
+!
To enable/disable the function:
a) Use the arrow buttons
to go to the setup menu
and then press
;
b) Use the
button to select the password “7” and then press
'
c) Select submenu
[1 0]
!
.
d) Use the
buttons to set one of the following values:
'
Off
+ Lock keypad disabled
'Lo+ Only the on/off button
is enabled
'
Hi
+
Lock keypad enabled
e) Press