1. In order to remove the Cross Flow Fan and Indoor Fan
Motor, Control Board need to be taken out by releasing all
the connectors as indicated below.
a. Release the Earth Wire screw. (Fig. 5)
b. Release the CN-REC/DISP connector. (Fig. 5)
c.
Release the CN-002 connector. (Fig. 5)
d. Release the CN-ION connector. (Fig. 5)
e. Release the CN-TH connector. (Fig. 5)
f.
Release the CN-SONIC connector. (Fig. 5)
g. Release the CN-STM2 connector. (Fig. 5)
h. Release the CN-STM1 connector. (Fig. 5)
i.
Pull out the Drain Hose from outlet to remove the
Discharge Grille. (Fig. 5)
2. Release the ION connectors. (Fig. 6)
3. Release the screws, you will be able to remove the Control
Board. (Fig. 6)
4. Remove the screw at the Cross Flow Fan. (Fig. 7)
5. Remove the Bearing. (Fig. 8)
6. Remove the screws at the left of the Evaporator. (Fig. 8)
Fig. 5
Fig. 6
Fig. 7
Fig. 8
12.6. Cross Flow Fan and Indoor Fan Motor Removal Procedures
74