Panasonic CS-F14DB4E5 Simplified Service Manual

Summary of CS-F14DB4E5

  • Page 1

    © 2006 panasonic ha air-conditioning (m) sdn bhd (11969-t). Unauthorized copying and distribution is a violation of law. Order no. Mac0605028c2 air conditioner cs-f14db4e5 cu-j28dbe5 cs-f14db4e5 cu-j28dbe8 cs-f18db4e5 cu-j34dbe5 cs-f18db4e5 cu-j34dbe8 cs-f24db4e5 cu-j43dbe8 cs-f28db4e5 cu-j50dbe8 ta...

  • Page 2: 1 Features

    2 1 features 1.1. Twin 1.1.1. Twin operation • simultaneous air conditioning of wide spaces and corners is possible. Indoor units with same horsepowers can even be used in combination. • master unit and slave-units can be set automatically in twin systems. No address setting is necessary. • multiple...

  • Page 3: 2 Product Specification

    3 2 product specification 2.1. Cs-f14db4e5 cu-j28dbe5 1. Cooling capacities are based on indoor temperature of 27 ° c d.B. (80.6 ° f d.B.), 19.0 ° c w.B. (66.2 ° f w.B.) and outdoor air temperature of 35 ° c d.B. (95 ° f d.B.), 24 ° c w.B. (75.2 ° f w.B.) 2. Heating capacities are based on indoor te...

  • Page 4

    4 2.2. Cs-f14db4e5 cu-j28dbe8 1. Cooling capacities are based on indoor temperature of 27 ° c d.B. (80.6 ° f d.B.), 19.0 ° c w.B. (66.2 ° f w.B.) and outdoor air temperature of 35 ° c d.B. (95 ° f d.B.), 24 ° c w.B. (75.2 ° f w.B.) 2. Heating capacities are based on indoor temperature of 20 ° c d.B....

  • Page 5

    5 2.3. Cs-f18db4e5 cu-j34dbe5 1. Cooling capacities are based on indoor temperature of 27 ° c d.B. (80.6 ° f d.B.), 19.0 ° c w.B. (66.2 ° f w.B.) and outdoor air temperature of 35 ° c d.B. (95 ° f d.B.), 24 ° c w.B. (75.2 ° f w.B.) 2. Heating capacities are based on indoor temperature of 20 ° c d.B....

  • Page 6

    6 2.4. Cs-f18db4e5 cu-j34dbe8 1. Cooling capacities are based on indoor temperature of 27 ° c d.B. (80.6 ° f d.B.), 19.0 ° c w.B. (66.2 ° f w.B.) and outdoor air temperature of 35 ° c d.B. (95 ° f d.B.), 24 ° c w.B. (75.2 ° f w.B.) 2. Heating capacities are based on indoor temperature of 20 ° c d.B....

  • Page 7

    7 2.5. Cs-f24db4e5 cu-j43dbe8 1. Cooling capacities are based on indoor temperature of 27 ° c d.B. (80.6 ° f d.B.), 19.0 ° c w.B. (66.2 ° f w.B.) and outdoor air temperature of 35 ° c d.B. (95 ° f d.B.), 24 ° c w.B. (75.2 ° f w.B.) 2. Heating capacities are based on indoor temperature of 20 ° c d.B....

  • Page 8

    8 2.6. Cs-f28db4e5 cu-j50dbe8 1. Cooling capacities are based on indoor temperature of 27 ° c d.B. (80.6 ° f d.B.), 19.0 ° c w.B. (66.2 ° f w.B.) and outdoor air temperature of 35 ° c d.B. (95 ° f d.B.), 24 ° c w.B. (75.2 ° f w.B.) 2. Heating capacities are based on indoor temperature of 20 ° c d.B....

  • Page 9: 3 Twin Systems

    9 3 twin systems 3.1. Installation manual.

  • Page 10

    10

  • Page 11: 4 Troubleshooting Guide

    11 4 troubleshooting guide 4.1. During twin operation system example 1. The main power is turned on while the transmission wires between the indoor units are not connected. (open circuit at a or b) symptom remote control unit: “check” flashes error code: f30-01 (connected indoor capacity error) indo...

  • Page 12

    12 indoor unit: led1 on p.C.B flashes outdoor unit: led6, 7 on p.C.B flashes 4. The main power is turned on and the connection wire is all ok. If operation starts in this condition, combination of the b50dbe8 outdoor unit and f24db4e5 indoor unit will result in abnormal operation. Symptom remote con...