Protherm 100 User Instructions - page 4
4
INSTALLATION INSTRUCTIONS
Introduction
The
Protherm 100 e
is a wall mounted combination boiler providing central heating and instantaneous domestic hot
water.
The boiler is of the II
2H3+
category for use with Natural gas (G20) as distributed in the United Kingdom, or with
Butane or Propane gas (G30/G31) with the appropriate conversion kit.
Conversion kit:
Conversion
Part No.
Natural gas (G20) to G30/G31 . . . . . . . 92321165
Modification must only be carried out by a suitably qualified engineer.
Boilers burning LPG or similar gases MUST NOT be fitted in basements or below ground level.
These instructions should be carefully followed for the safe and economical use of your boiler.
The boiler has a fan assisted, balanced, flue which both discharges the product of combustion to, and draws the
combustion air from the outside of the building.
Accessories
A range of accessories are available including, vertical flue components. For further information, contact you near-
est stockist.
Gas Safety (Installation and Use) Regulations
In the interests and that of gas safety, it is the law that ALL gas appliances are installed and serviced in by a competent
person in accordance with the above regulations.
Gas leak or fault
If a gas leak or fault exists or is suspected, turn the boiler and gas supply off and consult the local gas company or
your Installer/Service Provider.
Boiler controls
The control panel, located at the lower front of the boiler, allows the boiler to be started, shut down, controlled
and monitored during use, refer to
‘Users Instructions’.