Protherm Panther 24 KOV Operating Instructions Manual - page 5
5
Displaying heating water temperature
After turning the boiler on
with the main switch, the
current heating water tem-
perature will appear on the
display. This status is indi-
cated by the lit LED under-
neath the symbol .
Displaying hot water temperature
setting
When hot water is running,
only the required (set) tem-
perature is displayed on
the control panel display.
This status is indicated by
the lit LED underneath the
symbol .
Selecting Read mode
Displaying heating water pressure
By pressing the but-
ton, pressure (in bar) in
the heating water system
will be displayed for 30 se-
conds. The LED undernea-
th the symbol lit.
Low heating water pressure alert
When the pressure ei-
ther drops below 1 bar
or exceeds 2.5 bar, the
LED underneath the sym-
bol lashing. The boiler
remains functional, but the
water pressure must be
adjusted to the recommended value of
1.2 – 2 bar.
Selecting Setup mode
Setting hot water temperature
Press the button
repeatedly until the LED
underneath the symbol
starts fl ashing. By pres-
sing the buttons set
the hot water temperature
to the required value. The setting range is
--, 40, 42, 45, 48, 50, 52, 55, 58, 60˚C
By pressing the button once more,
the set value will be saved in the memory.
If you wish to disable the hot water heating
function, set the value to --.
Setting hot water to COMFORT mode
Press the button. The
LED underneath the sym-
bol will start fl ashing. To
disable the COMFORT
function, press the but-
ton again. For further de-
tails see page 11.
Setting heating water temperature
Press the button
repeatedly until the LED
underneath the symbol
star ts flashing. By
pressing the but-
tons set the heating wa-
ter temperature to the required value. The
setting range is --, 45, 50, 55, 60, 65, 70,
75, 80, 85˚C.
To set the boiler to the SUMMER mode
(hot water heating only), set the value to
(--).
Resetting back to factory values
Using main switch (Fig. 1), turn the boiler
off. Then press the button and turn the
boiler on again with the main switch.
Note:
factory set values are shown in
Fig. 4.