Protherm Panther 24 KOV Operating Instructions Manual - page 9
9
Starting the boiler up
Important:
Putting the boiler into operati-
on and starting it up for the fi rst time must
be done by an authorised service only!
If you wish to start the boiler up after it has
been put into operation, make sure that:
1. the boiler is connected to power supply
2. the gas valve underneath the boiler
is opened
3. the heating water pressure is within
the range 1,2 - 2bar
Turn the main switch (Fig. 1) to the ON
position (I). The display lights up.
In the event of a safety boiler shutdown due
to the loss of fl ame, reaction by the emer-
gency thermostat or the combustion gases
thermostat (in boiler 24 KOV), error code F1
will appear on the display. If the shutdown
was caused by the loss of fl ame, the boiler
can be unblocked by pressing the RESET
button. If the emergency shutdown recurs
after a short time again, or if the boiler can-
not be unblocked by pressing the RESET
button, call an authorised service.
If the emergency shutdown was triggered
by the emergency thermostat, mere pres-
sing the RESET button will not unblock
the boiler. Unblocking the emergency
thermostat must be done by an authori-
sed service technician, and this operation
cannot be regarded as a warranty repair.
Important:
The boiler must not be run
with the emergency or the combustion ga-
ses thermostat disabled or replaced with
a device other than the one specifi ed by
the manufacturer.
shutting the boiler down
Turn the main swich (Fig. 1) to the OFF
position (0).
If the boiler is to remain shut down for a
longer period of time, turn the gas supply
valve underneath the boiler off. When
shutting the boiler down, take into consi-
deration the ambient temperature in the
given season. Unless the boiler is fi lled
in with antifreeze (Alicol Termo), both the
boiler and the system could get damaged.
In such case drain the hot water distribution
pipes completely.
Starting the boiler up and shutting it down