Protherm PTCP User Manual - 1. Description
INSSTCP0408
1. Description
The PTCP electronic thermostat can be used to control heat-
ing floors with electrical current − with a resistive load − rang-
ing from 0 A to 16 A at 120/208/240 VAC. It has an easy user
interface and can manage up to four programming periods a
day. It keeps the temperature of a room (Ambient mode) and a
floor (Floor mode) at a requested set point with a high degree
of accuracy.
Floor Mode
(factory setting): this control method is ideal in ar-
eas where you want a hot floor at any time and when the temper-
ature of the ambient air can be high without causing discomfort.
For example, in a bathroom.
WARNING
WARNING
Before installing and operating this product, the
owner and/or installer must read, understand and fol-
low these instructions and keep them handy for fu-
ture reference. If these instructions are not followed,
the warranty will be considered null and void and the
manufacturer deems no further responsibility for this
product.
Moreover, the following instructions must
be adhered to in order to avoid personal injuries
or property damages, serious injuries and poten-
tially fatal electric shocks.
All electric connections
must be made by a qualified electrician, according to
the electrical and building codes effective in your re-
gion. Do NOT connect this product to a supply source
other than 120 VAC, 208 VAC or 240 VAC, and do not
exceed the specified load limits. Protect the heating
system with the appropriate circuit breaker or fuse.
You must regularly clean dirt accumulations on or in
the thermostat. Do NOT use fluid to clean thermostat
air vents. Do NOT use where exposed to water. Suitable
for insulated walls.