Protherm PTCP User Manual - page 8
INSSTCP0408
Temperature Set Points
The figures displayed beside the word “SET” indicate the ambi-
ent or the floor temperature set points. They can be displayed
in degrees Celsius or Fahrenheit (see “Display in degrees Cel-
sius/Fahrenheit”).
Out of any adjustment mode, press down the + button to in-
crease the set point, or the - button to decrease it. Set points
can only be adjusted by increments of 1 degree. To quickly scroll
through the set point values, press and hold down the button.
Maximum Floor Temperature Limitation
At any time, the floor temperature (in Floor mode) is maintained
at less than 28°C (82°F) in order to avoid overheating caused
by an excessive heating request, which could damage some
materials or be detrimental for health. It is however possible to
increase this limit to 35°C (95°F). To do so, you must press down
the A/F button for at least 20 seconds. After 20 seconds, the
new maximum temperature will be displayed in replacement of
the Floor mode set point and will blink during 5 seconds. Then,
you can release the A/F button. To return to a maximum tem-
perature of 28°C, you must repeat the operation. Regardless of
the maximum floor set point (Floor mode), the maximum Ambi-
ent mode set point will always be 35°C.
Adjustment of the Hour and the Day of the Week
Adjustment procedure of the hour and the day of the week.
1. Press down the Day/Hr button, whether it is in Man, Auto or
Pre Prog mode.
2. At this moment, the SET icon and the day of the week blinks
and you can adjust the day of the week using the + or - button
and confirm your choice by pressing down the Mode or Day/
Hr button. You can also press down the desired day of the
week button without using the + or - button and confirm your
choice using the Mode or Day/Hr button.
3. The two figures indicating the hour blink. You must adjust them
using the + or - button and confirm your choice by pressing
down the Mode or Day/Hr button.