    Page 1 7033-308d march 4, 2015 quadra-fire 3100 series acc wood burner installation instructions quadra-fire 3100 series acc wood burner installation instructions installations to comply with as/nzs2918:2001 and will require a building consent important: read all instructions carefully before starti...

  • Page 2

    Page 2 7033-308d march 4, 2015 3100 series acc wood burner hearth & home technologies welcomes you to our tradition of excellence! In choosing a quadra-fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market...

  • Page 3

    March 4, 2015 7033-308d page 3 3100 series acc wood burner quadra-fire 3100 millenium acc wood burner dimensions 616 mm 533 mm 254 mm 457 mm 273 mm 397 mm 379 mm 484 mm 749 mm 90 mm 25 mm 499 mm 406 mm 677 mm 46 mm quadra-fire 3100 limited edition acc wood burner dimensions 978mm 1320mm 641mm 454mm ...

  • Page 4

    Page 4 7033-308d march 4, 2015 3100 series acc wood burner description pioneer double flue mounted shield universal shall be fitted with double flue shield fitted a min. Clearance from back of unit to rear wall 175mm b min. Clearance from center of spigot to rear wall 345mm c min. Distance from fron...

  • Page 5

    March 4, 2015 7033-308d page 5 3100 series acc wood burner corner positioning (45°) description pioneer double flue mounted shield universal shall be fitted with double flue shield fitted a min. Clearance from fi rebox corner to corner walls 225mm b min. Distance from center of spigot to corner wall...

  • Page 6

    Page 6 7033-308d march 4, 2015 3100 series acc wood burner quadra-fire 31 step top acc wood burner dimensions 678mm 618mm 391mm 292mm 406mm 527mm 870mm 635mm 318mm 237mm cl 457mm 606mm 841mm 194mm 537mm 264mm 170mm 89mm cl.

  • Page 7

    March 4, 2015 7033-308d page 7 3100 series acc wood burner description pioneer double flue mounted shield universal shall be fitted with double flue shield fitted a min. Clearance from back of unit to rear wall 175mm b min. Clearance from center of spigot to rear wall 345mm c min. Distance from fron...

  • Page 8

    Page 8 7033-308d march 4, 2015 3100 series acc wood burner corner positioning (45°) description pioneer double flue mounted shield universal shall be fitted with double flue shield fitted a min. Clearance from fi rebox corner to corner walls 130mm b min. Distance from center of spigot to corner wall...

  • Page 9

    March 4, 2015 7033-308d page 9 3100 series acc wood burner 3100 limited edition special instructions removing from pallet 1 2 1. Remove tile frames from both sides by lifting up and away. (fig. 14.3) 2. Remove both side panels using a phillips screwdriver to remove 4 screws on back (fig. 14.1) 3. Us...

  • Page 10

    Page 10 7033-308d march 4, 2015 3100 series acc wood burner ▪ flue pipe installed crimp/narrow end down ▪ outer casings installed crimped/narrow end up. (critical when exposed above the roof) ▪ inner casings - direction not critical ▪ flue pipes - seal all joints including fi rebox spigot. - fi x wi...

  • Page 11

    March 4, 2015 7033-308d page 11 3100 series acc wood burner c l dr aw in g n o t t o s c a le 12 tested flue systems, as per as/nzs 2918:2001 fig. 5 add cowl casing cover spider bracket oversized casing cover is necessary minimum 25mm gap between flue pipe casing & combustible material non combustib...

  • Page 12

    Page 12 7033-308d march 4, 2015 3100 series acc wood burner 150 flue penetration 1.Qf.1f un-tested flue systems, as per as/nzs 2918:2001, 4.6.3(b) fig. 6 as/nzs2918:2001 un-tested flue with sloped ceiling penetration greater than 30° from horizontal a = 25mm 4.6.3(b) fig 4.6 = downward distance of c...

  • Page 13

    March 4, 2015 7033-308d page 13 3100 series acc wood burner 1. Unpack the flue mounted shield, detach the three brackets and familarize yourself with the illustra- tions. 2. Using a sharp knife or razor blade, carefully cut through the plastic fi lm on the “inside face” where it meets the outer shie...

  • Page 14

    Page 14 7033-308d march 4, 2015 3100 series acc wood burner warnings: warning: the appliance and flue system shall be installed in accordance with as/nzs 2918 and the appropriate requirements of the relevant building code or codes. Warning: appliances installed in accordance with this standard shall...

  • Page 16

    Page 16 7033-308d march 4, 2015 we recommend that you record the following pertinent information for your 3100 series acc stove date purchased/installed: serial number: location on appliance: dealership purchased from: dealer phone: notes: do not discard this manual caution • important operating and...