Quadra-Fire 31M-ACC-AU Installation Instructions Manual - page 7
March 4, 2015
7033-308D
Page 7
3100 Series ACC Wood Burner
DESCRIPTION
Pioneer Double Flue Mounted Shield Universal
Shall be Fitted
With Double Flue
Shield Fitted
A
Min. Clearance from back of unit to rear wall
175mm
B
Min. clearance from center of spigot to rear wall
345mm
C
Min. distance from front of base to fl oor protector front
300mm
D
Min. fl oor protector front width
800mm
E
Min. distance from rear wall to front of fl oor protector
1062mm
F
Min. distance from unit side to side wall
325mm
G
Min. clearance from center of spigot to side wall
633mm
Quadra-fi re 3100 Step Top ACC does not require a insulating Floor Protector, as they are tested and
comply with the minimum Floor Protector requirements of AS/NZS 2918:2001.
Note:
▪ The minimum Floor Protector sizes are specifi ed in the clearance chart, see Table 3 & 4.
▪ A Floor Protector can include ceramic tiles with grouted joints fi xed directly onto a wooden fl oor or
a sheet of toughened glass, panel steel or any other non combustible material laid directly onto a
wooden fl oor.
▪ If installed directly onto a concrete slab, the concrete slab can be considered as the fl oor
protector,but must maintain the minimum measurement listed.
FLOOR PROTECTOR - 31 Step Top
PARALLEL POSITIONNG - 31 Step Top
NOTE: HEAT SHIELD REQUIREMENTS FOR HEAT SENSITIVE WALLS
Clearances may be reduced by provision of an appropriately located heat shield refer to
AS/NZS 2198:2001 3.2.3 TABLE 3.1
Table 3
Fig. 5
FLOOR PROTECTOR
B
C
D
F
E
A
G
REAR WALL
SIDE W
ALL
REAR W
ALL