Quadra-Fire 31M-ACC-AU Installation Instructions Manual - page 13
March 4, 2015
7033-308D
Page 13
3100 Series ACC Wood Burner
1. Unpack the Flue Mounted Shield, detach the three brackets and familarize yourself with the illustra-
tions.
2. Using a sharp knife or razor blade, carefully cut through the plastic fi lm on the “inside face” where
it meets the outer shield (refer sketch). Cut along the full length of the Flue Mounted Shield on both
side, then peel off and fully remove the plastic fi lm from the stainless steel inner shield.
3. Peel back and fully remove the plastic fi lm from the outer shield.
4. Fit the top bracket to the Flue Mounted Shield as illustrated ensuring the rear mid section of the
bracket fi ts “outside” while the two outer sections of the bracket fi t “inside”.
5. Fit the appropriate lower bracket to your woodfi re.
Lower Bracket “5B suitable for all other woodfi res without an inner rear heatshield. On certain model
woodfi res without a raised fl ue spigot it will be necessary to cut off both the lower outer legs from the
bracket “5B” leaving the entral tongue to locate inside the fl ue outlet only.
Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will
mount lower onto the appliance.
The Flue Mounted Shield then locates into the two notches provided n bracket “5B” as illustated.
6. Once the Flue Mounted Shield is fi tted in position onto either of the two lower mounting brackets,
check to ensure a large gap is not present between the top of the woodfi re and the base of the Flue
Mounted Shield, as this may result in a hot spot on the rear wall directly behind the fl ue outlet. If your
woodfi re has a lift off top grill the Flue Mounted Shield should be raised suffi ciently to enable the top
grill to be removed.
7. Using the pre-punched holes in the two tabs provided on the top bracket as guides, drill into the
fl ue pipe and secure the top bracket to the fl ue pipe with two stainless steel rivets (not supplied).
GENERAL INSTRUCTIONS FOR FLUE SYSTEM
MINIMUM HEIGHT OF FLUE SYSTEM EXIT
Fig. 8
3000
3000
or less
More than 3000
600 min.
3000
increase as necessary
until nothing within
3000mm of flue top
Any nearby structure
increase from 1000mm
minimum until clear within
3000mm of flue top
Fig. 10