Quadra-Fire CB1200M-MBK Owner's Manual - page 10
10
7014-259B
November 30, 2017
CB1200 FREESTANDING
M. Clear Space
NOTICE:Clearances may only be reduced by means ap-
proved by the regulatory authority having jurisdiction.
Mantel: Avoid placing candles and other heat-sensitive
objectsonmantelorhearth.Heatmaydamagetheseobjects.
Fire Risk.
Keep combustible materials, gasoline and other
flammablevaporsandliquidsclearofappliance.
•DoNOTstoreflammablematerialsinthe
appliance’svicinity.
•
DO NOT USE GASOLINE, LANTERN FUEL, KEROSENE,
CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO
START OR “FRESHEN UP” A FIRE IN THIS Appliance.
•
DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS
SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.
•
DO NOT USE CHEMICALS OR FLUIDS TO START THE
FIRE.
• Keep all such liquids well away from the appliance while it is
in use.
• Combustible materials may ignite.
WARNING
Fire Risk.
DoNOTplacecombustibleobjectsinfrontofthe
appliance. Hightemperaturesmayignitecloth-
ing, furniture or draperies. Maintainaminimum
clearanceof3feet(914mm)infrontofappliance.
WARNING
L. Restarting the Appliance
RestartProcess
1. When the unit has run out of fuel and the “empty
hopper”errorcodeilluminates,addpelletfueltothe
hopper.
2. Dumptheashesandclinkersbuiltupinthefirepotby
pulling the ash dump removal handle out several times.
Makesureclinkershavedroppedintotheashpanthen
return the handle to fully closed position.
3. TurnthedialcontroltoOFFandthenuptohigh2Xto
prime.
4. After seeing pellets drop then turn to desired setting to
reset the appliance control system. The appliance will
then being its startup sequence.
RestartingAfteraPowerFailure
1. Foranelectricaldisruptiontheappliancewillstarton
its own without need for priming - providing the control
system is asking for heat.
2. The appliance will always go through a normal shut-
down sequence before restarting.
There is a 4 screw terminal block located on the back
lower left corner of the stove directly above the power
cord inlet. The center 2 screws are for the thermostat
wires (see
Figure 11.1 on page 11).
N. Thermostat Installation and Operation
Theappliancecomesstandardwithawallthermostatand25’
ofwire.Ifyouneedtorunmorethan25’makesureyouuse
acontinuousstrandof18to22gaugethermostatwire.For
optimum performance your thermostat should be located on
aninsidewallapproximately5’upfromthefloor.
How to Install Your Wall Thermostat
1. Separatethebodyofthethermostatfromthemounting
plate by gently pulling the two pieces apart
2. Connect your thermostat wire to the W and R terminals
(see
Figure 11.2 on page 11)
3. Screwthebackerplatetothewallusingthehardware
included
4. Snapthethermostattothebackerplate
5. Connect the wires to the 2 center screws on the terminal
block on the back of the product
Battery Installation and Replacement
NOTE: 2 AA batteries are included with the thermostat
and must be installed before the appliance can be oper-
ated
(see
Figure 11.3 on page 11)
.
Installfreshbatteriesimmediatelywhenthe
REPLACE
BATTERY warningbeginsflashing.Thewarningflashes
about two months before the batteries are depleted.
Even if the warning does not appear, you should replace
batteries once a year.
Ifbatteriesareinsertedwithintwominutes,thetimeand
day will not have to be reset. All other settings are perma-
nently stored in memory.
Shockhazard.
• DoNOTremovegroundingprongfromplug.
• Plugdirectlyintoproperlygrounded3prong
receptacle.
• Route cord away from appliance.
• DoNOTroutecordunderorinfrontofappli-
ance.
CAUTION