Quadra-Fire SANTAFE-MBK Installation Manual

Manual is about: SANTA FE PELLET STOVE

Summary of SANTAFE-MBK

  • Page 1

    1 7050-145e august 3, 2015 santa fe pellet stove model(s): santafe-mbk installation manual installation & appliance set-up installer: leave this manual with party responsible for use and operation. Owner: retain this manual for future reference. Notice: do not discard this manual o-t l tested and li...

  • Page 2

    2 7050-145e august 3, 2015 santa fe freestanding table of contents safety alert key: • danger!Indicates a hazardous situation which, if not avoided will result in death or serious injury. • warning! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • caut...

  • Page 3

    August 3, 2015 7050-145e 3 santa fe freestanding model santa fe pellet stove laboratory omni test laboratories, inc. Report no. 061-s-77d-6.2 type solid fuel room heater/pellet fuel burning type standard astm e1509-04, ulc s627-00 and ulc/ord-c1482-m1990 room heater pellet fuel burning type and (um)...

  • Page 4: Install Guide

    4 7050-145e august 3, 2015 santa fe freestanding install guide 2 getting started marginal location: • below peak location not recommended: • not the highest point of the roof • wind loading possible multi-level roofs windward leeward recommended: outside air intake on windward side not recommended: ...

  • Page 5

    August 3, 2015 7050-145e 5 santa fe freestanding • i n s t a l l a t i o n a n d u s e o f a n y d a m a g e d appliance. • modifi cation of the appliance. • installation other than as instructed by hearth & home technologies. • installation and/or use of any component part not approved by hearth & ...

  • Page 6

    6 7050-145e august 3, 2015 santa fe freestanding attention installer: follow this standard work checklist this standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual. Customer: date installed: lot/address: lo...

  • Page 7

    August 3, 2015 7050-145e 7 santa fe freestanding figure 7.2- front view figure 7.1 - top view figure 7.3 -side view figure 7.4 - side view with top vent adapter 25-1/2 in. (658mm) 12-3/4 in. (324mm) 21-1/4 in. (540mm) 28-11/16 in. (729mm) 16-3/4 in. (426mm) 28-1/8 in. (715mm) 25-11/16 in. (653mm) 3-...

  • Page 8

    8 7050-145e august 3, 2015 santa fe freestanding straight back against wall inches millimeters a back wall to appliance 2 51 b side wall to appliance 6 152 corner installation inches millimeters c walls to appliance 2 51 vertical installation inches millimeters d back wall to flue pipe 3 76 e side w...

  • Page 9

    August 3, 2015 7050-145e 9 santa fe freestanding 4 vent information a. Venting termination minimum requirements j or k x v m i h a v g b v v a b v f v c b b e l v d v electrical service v n v n v n n v inside corner fixed closed open open fixed closed v x g g termination cap air supply inlet gas met...

  • Page 10

    10 7050-145e august 3, 2015 santa fe freestanding b. Avoiding smoke and odors negative pressure, shut-down and electrical power failure to reduce the probability of back-drafting or burn-back in the pellet appliance during power failure or shut down con- ditions, it must be able to draft naturally w...

  • Page 11

    August 3, 2015 7050-145e 11 santa fe freestanding to minimize the effects of negative air pressure: • install the outside air kit with the intake facing prevailing winds during the heating season • ensure adequate outdoor air for all combustion appliances and exhaust equipment • ensure furnace and a...

  • Page 12

    12 7050-145e august 3, 2015 santa fe freestanding g. Equivalent feet of pipe the table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size. Figure 12.1. 2 ft. 2 ft. 3 ft. 2 ft. Example of 3 elbow-rear vent termination calculation pellet venti...

  • Page 13

    August 3, 2015 7050-145e 13 santa fe freestanding i. Pellet venting charts the maximum horizontal venting allowed with no vertical vent- ing attached is 48 inches (1219mm) including one 90° elbow or two 45° elbows. This is our recommended horizontal vent- ing installation. Addition of any horizontal...

  • Page 14

    14 7050-145e august 3, 2015 santa fe freestanding a c b d 5 venting systems note: • illustrations refl ect typical installations and are for design purposes only. • i llustrations/diagrams are not drawn to scale. • actual installation may vary due to individual design preference. A. Alcove figure 14...

  • Page 15

    August 3, 2015 7050-145e 15 santa fe freestanding straight out figure 15.1 figure 15.2 45 degree wall thimble illustration shows venting going in both directions. Choose which one is best for your installation. 2 in. (51mm) minimum 2 in. (51mm) minimum 6 in. (152mm) minimum 6 in. (152mm) minimum 6 i...

  • Page 16

    16 7050-145e august 3, 2015 santa fe freestanding d. Through the wall & vertical - exterior figure 16.1 figure 16.2 e. Vertical - interior - typical installation figure 16.3 firestop flashing rain cap 6 in. (152mm) min. Non-combustible hearth pad 3 in. (76mm)min. 12 in. (305mm) minimum 3 in. To 3 in...

  • Page 17

    August 3, 2015 7050-145e 17 santa fe freestanding f. Masonry g. Alternate masonry figure 17.1 figure 17.2 non-combustible hearth pad airtight cleanout door cleanout cover sheathing 3 in. (76mm) minimum 1 in. (25mm) clearance flashing fireclay flue liner with airspace concrete cap 1 in. (25mm) cleara...

  • Page 18

    18 7050-145e august 3, 2015 santa fe freestanding termination cap hose clamp trim ring flex hose collar assembly 6 appliance set-up a. Outside air kit instructions parts included in kit: 1 piece of 2 inch x 3 foot fl ex hose, 2 hose clamps, 1 air intake channel1 collar assembly, 1 ter- mination cap ...

  • Page 19

    August 3, 2015 7050-145e 19 santa fe freestanding silicone rear exhaust outlet 3 to 6 inch offset adapter use hole on each side as drilling guide 3 to 3 inch top vent adapter drill holes in back of stove and secure with 4 screws, 2 on each side clean-out cover c. Top vent adapter installation 3 to 3...

  • Page 20

    20 7050-145e august 3, 2015 santa fe freestanding e. Optional log set placement instructions 2 piece log set installation 1. Open door to expose the fi rebox. 2. Install the left log fi rst and then the right log. Figure 20.1 3. Lean the logs against the cast iron brick in the back of the fi rebox. ...

  • Page 21

    August 3, 2015 7050-145e 21 santa fe freestanding f. Thermostat installation (continued) the appliance comes standard with a wall thermostat and 25’ of wire. If you need to run more than 25’ make sure you use a continuous strand of 18 to 22 gauge thermostat wire. For optimum performance your thermos...

  • Page 22

    22 7050-145e august 3, 2015 santa fe freestanding g. Optional nickel or black nickel grille figure 22.1 heat exchanger rods grille bracket cover (shipped flat from factory) finger bend into position after grilles are installed on appliance insert heat exchanger rods through holes on second grille. I...

  • Page 23

    August 3, 2015 7050-145e 23 santa fe freestanding 7 mobile home installation you must use a quadra-fire outside air kit for installation in a mobile home. 1. An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted...

  • Page 24: Santafe-Mbk

    24 7050-145e august 3, 2015 santa fe freestanding 8 accessory list service parts santafe-mbk beginning manufacturing date: june 2009 ending manufacturing date: active important: this is dated information . Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell...

  • Page 25

    August 3, 2015 7050-145e 25 santa fe freestanding.

  • Page 26

    26 7050-145e august 3, 2015 santa fe freestanding.

  • Page 27

    August 3, 2015 7050-145e 27 santa fe freestanding.

  • Page 28

    28 7050-145e august 3, 2015 do not discard this manual caution • important operating and maintenance instruc- tions included. • leave this manual with party responsible for use and operation. • read, understand and follow these instruc- tions for safe installa- tion and operation. Do not discard con...