QUANTA 230W Security Floodlight Installer's Manual

Summary of 230W Security Floodlight

  • Page 1

    Iq-nalp-180-300-d-gr v4.0 -10/11 inst aller guide 230w security floodlight quanta.

  • Page 2: Section One

    Section one general information the unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the lamp will illuminate for a user-determined time period. An integral daylight sensor ensures night-only operation. This unit has a dual light level operat...

  • Page 3: Section Three

    Section three installation after choosing a suitable location (see previous section) install the unit as follows: the unit is suitable for connection to a 240v 50hz electricity supply. It is suggested that 3-core round flexible cable of 1mm² gauge is used. An internal switch should be installed to s...

  • Page 4: Section Four

    Section four operation and testing walk testing procedure the sensor will rotate from left to right. Adjust the sensor to point in the desired direction. See diagram a & h for the different sensor patterns and lens masking. See diagram c & i for the adjustment controls. Set the time,dusk and dim con...

  • Page 5

    Less sensitive more sensitive top view side view 12m 2.5m a c b d lux time timer dim 180 degrees.

  • Page 6

    Installation diagram e.

  • Page 7

    Wall plate cable entry blue green/yellow brown (n) (e) (l) match the three pins on the unit to the wall plate. Connect the mains cable to n,e & l connections in the terminal block connection diagram f.

  • Page 8

    The floodlight can be adjusted to angle the beam to cover the required area g h h lens masking diagram the arrows indicate the front of the detection area in that section of the sensor caution if the protective glass shield for the light is damaged or cracked it must be replaced immediately. `8 `8 `...

  • Page 9: Section Five

    Adjustment knobs timer control mode the dusk time setting controls how long the unit remains illuminated after dusk if the unit is set in timer control mode. (see section 5). The unit can be set to illuminate between 1 and 8 hours, then it will switch the unit off until dusk the following evening. T...

  • Page 10

    Setting up for automatic operation. When walk tests are complete, the unit can be switched to automatic operation : the time setting controls how long the unit remains illuminated following activation & after all motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the...

  • Page 11: Section Five

    Section five technical specifications detection range detection angle power supply maximum switchable load lamp type timer control time on adjustment lux level adjustment environmental protection up to 12 metres 180º 240v ~ 50hz 300w 118mm linear tungsten halogen 300w max (r7s cap) adjustable 1 to 8...

  • Page 12: Section Six

    Section six troubleshooting guide problem o lamp stays on all the time at night. O pir keeps activating for no reason / at random. O pir sensor will not operate at all. O the pir sensor will not operate at night. O unit activates during the daytime o pir coverage is poor/sporadic o detection range v...