QUANTA 230W Security Floodlight Installer's Manual - Section Three
SECTION THREE
INSTALLATION
After choosing a suitable location (see previous section) install the unit as follows:
The unit is suitable for connection to a 240V 50Hz electricity supply. It is suggested that
3-core round flexible cable of 1mm² gauge is used. An internal switch should be installed to
switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not
required or for maintenance purposes.
Unfasten the clip on the top of the floodlight glass shield. Install the halogen bulb, making sure
not to touch the bulb with bare hands. It is suggested that the bulb is handled using a dry cloth.
Ensure the bulb is correctly fitted in the lampholder before use.
Re-attach the clip to secure the glass shield to the floodlight.
Remove the wall plate from the unit by inserting a terminal screwdriver into the slot at the top,
See diagram D.
Mark the position of the fitting holes.
Drill the holes. Insert wallplugs into the holes.
BEFORE SECURING THE WALLPLATE TO THE WALL PIERCE & PASS THE CABLE
THROUGH THE GROMMET.
Attach the wall plate to the wall. See Diagram E
CONNECTION
Connect the cable to the terminal block on the wallplate as follows (see connection diagram):
NEUTRAL (Blue)
N
EARTH (Green/Yellow)
LIVE (Brown)
L
Ensure that the connections are secure.
To reattach the unit to the wall plate line up the two pins at the top of the unit.
Push the unit against the wall plate and the unit will 'Click' into place. Ensure that the bottom clip
is fully closed to ensure a water proof seal.
See Diagram F.