Quidway V100R006C00 Configuration Manual - 2.2.3 Remote Login
IP addresses are configured for establishing NAP connections.
The default IP address pool for establishing NAP connections is 10.167.253.0/24.
When configuring IP addresses, ensure that the primary IP addresses of both the master
and the slave interfaces are on the same network segment, and that the secondary IP
addresses of both the master and the slave interfaces are on the same network segment.
----End
2.2.3 Remote Login
After the neighbor relationship is set up, you can log in to the NAP slave device from the NAP
master device.
Context
Using the
display nap
interface
command, you can view the NAP status of an interface to
ensure that the interface is assigned a correct IP address.
Do as follows on the switch where the NAP master interface is configured.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
interface
interface-type
interface-number
The interface view is displayed.
Step 3
Run:
nap login neighbor
The login to the slave device from the master device is performed.
l
If the slave device has an empty configuration, you can log in to the slave device from the
master device without a user name and a password.
l
If, however, the slave device is configured with user name(s) and password(s), you must
enter the correct user name and password to perform a NAP-based remote login to the slave
device.
NOTE
To ensure security for NAP, the slave device having an empty configuration checks the source address of
the Telnet login. If the Telnet source address is the NAP address of the master device that is telnetting to
the slave device, the slave device allows the master device to directly log in without being authenticated.
This is because by default, the user level of the remote login based on the NAP address is the same as the
login through the console interface, which enjoys the highest user level. If the Telnet source address is not
the NAP address of the master device, the remote login fails.
If
ip source check user-bind enable
command is executed on an interface, the interface cannot connect
to the NAP neighbor.
----End
Quidway S6700 Series Ethernet Switches
Configuration Guide - Device Management
2 NAP Configuration
Issue 02 (2011-10-01)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
17