- DL manuals
- R.V.R. Electronica
- Transmitter
- PJ1000-LIGHT
- User Manual
R.V.R. Electronica PJ1000-LIGHT User Manual
Summary of PJ1000-LIGHT
Page 1
Pj1000-light user manual volume 1 manufactured by italy.
Page 2
Pj1000-light - user manual version 1.1 © copyright 2005 r.V.R. Elettronica spa via del fonditore 2/2c - 40138 - bologna (italia) telephone: +39 051 6010506 fax: +39 051 6011104 email: info@rvr.It web: www.Rvr.It all rights reserved printed and bound in italy. No part of this manual may be reproduced...
Page 3: Pj1000-Light
Pj1000-light i user manual rev. 1.1 - 12/12/05 table of contents 1. Preliminary instructions 1 2. Warranty 1 3. First aid 1 3.1 treatment of electrical shocks 1 3.2 treatment of electrical burns 2 4. Unpacking 3 4.1 general description 3 5. Quick guide for installation and use 5 5.1 preparation 5 5....
Page 4: Pj1000-Light
Pj1000-light ii user manual rev. 1.1 - 12/12/05 this page was intentionally left blank.
Page 5: Pj1000-Light
1 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 1. Preliminary instructions this manual is written as a general guide for those having previous knowledge and experience with this kind of equipment, well conscious of the risks connected with the operation of electrical equipment. It is not intend...
Page 6: Pj1000-Light
2 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light • clear out mouth if necessary and observe for breathing • if not breathing, begin artificial breathing ( figure 2): tilt head, pinch nostrils, make airtight seal, four quick full breaths. Remember mouth to mouth resuscitation must be commenced as ...
Page 7: Pj1000-Light
3 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 4. Unpacking the package contains: 1 pj1000-light 1 user manual 1 mains power cable the following accessories are also available from your r.V.R. Dealer: • accessories, spare parts and cables 4.1 general description the pj1000-light is an ...
Page 8: Pj1000-Light
4 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light theamplifiermanagementsoftwareisbasedonamenusystem.Userhasfour navigation buttons available to browse submenus: esc (chap. 6.1 - [6]), , , and enter (chap. 6.1 - [9]). The rear panel features the mains input connectors with a mains voltage switch (...
Page 9: Pj1000-Light
5 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 5. Quick guide for installation and use this section provides a step-by-step description of the machine installation and configuration procedure. Follow these procedures closely upon first power-on andeachtimeanychangeismadetogeneralconfiguration,s...
Page 10: Pj1000-Light
6 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 5.1.2 mains power supply warning: disconnect mains power supply before beginning these procedures. Both power supply units (please see chapter 8.1 for a detailed description) are equipped with fuses and voltage selection blocks: check all fuses and...
Page 11: Pj1000-Light
7 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light figure 5.1: voltage selection jumper on pfc 5.1.3 connections connect the output of a suitable fm exciter (for instance, ptx30-lcd exciter availablefromr.V.R.Elettronica)totherfinput(seefigure6.2-item[8])using a 50-ohm coaxial cable with “n”-type c...
Page 12: Pj1000-Light
8 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light figure 5.2: connection to exciter 5.2 first power-on and setup follow this procedure upon first power-on and after making changes to the configurationofthetransmitterinwhichtheamplifierisintegrated. Note : standard factory settings are rf power out...
Page 13: Pj1000-Light
9 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 5.2.3 power check ensure that the onlightturnson(seefigure6.1-item[1]).Machinenameshould appearbrieflyonthedisplay,quicklyfollowedbyforwardandreflectedpower readings(figure5.2-menu1).Ifrfoutputisdisabled,thesereadingswillbe zero. 5.2.4 how to enabl...
Page 14: Pj1000-Light
10 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light open the power setup menu(figure5.2-menu2)pressingthefollowingkeys in the order: esc (opens default menu) ⇒ enter (hold down for 2 seconds) use set menu and keystosetthedesiredamplifieroutputpower;theset bar at the side provides a graphic display ...
Page 15: Pj1000-Light
11 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 5.3 operation 1) powerontheamplifier(chap.6.1-[11])andensurethatthe on light turns on (chap.6.1-[1]).Machinenameshouldappearbrieflyonthedisplay,quickly followedbyforwardandreflectedpowerreadings(menu1),providedthatthe amplifierisdeliveringoutputpo...
Page 16: Pj1000-Light
12 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 2) ensure that machine is not in a locked-out state. Press the esc key (chap. 6.1 - [6]) to call up the selection screen (menu 3). Highlight fnc and press enter toconfirm(chap.6.1-[9])andaccesstheappropriatemenu(menu4). If loc is set to remote (ma...
Page 17: Pj1000-Light
13 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light (three empty arrows) - parameter is being edited. (empty arrow) - current line marker; the parameter in this line cannot be edited. This symbol appears in menus that take up more than two lines to aid browsing. Menu 1 menu 1 operation menu power m...
Page 18: Pj1000-Light
14 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light to gain access to a submenu, select menu name (name is highlighted by cursor) using button or and press the enter button (chap. 6.1 - [9]). Press esc again (chap. 6.1 - [6]) to return to the default menu (menu 1). 5.4.1 operation menu (fnc) 5.4.1 ...
Page 19: Pj1000-Light
15 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 5.4.2 power menu (pwr) this screen holds all readings related to machine output power: menu 5 fwd forward power reading. Rfl reflectedpowerreading. Inp input power reading. Note that these are readings, rather than settings, and cannot be edited (...
Page 20: Pj1000-Light
16 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 5.4.4 alarm menu (alm) this menu shows any alarm conditions occurring during machine operation. Alarm thresholds are preset at the factory. Menu 7 fwd counter of alarm conditions triggered by forward power. Rfl counterofalarmconditionstriggeredbyr...
Page 21: Pj1000-Light
17 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 1. Over forward power forward power threshold exceeded. Alarm 1 2. Overreflectedpower reflectedpowerthresholdexceeded. Alarm 2 3. Over input power input power threshold exceeded. Alarm 3 monitoring cycle is as follows: • an alarm condition occurs;...
Page 22: Pj1000-Light
18 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light ii. Overreflectedpower reflectedpoweralarmdisplay. Stop 2 iii. Over input power input power alarm display. Stop 3 once the machine goes into “fault/lock” mode, it will no longer attempt to re-start; choose the appropriate reset procedure according...
Page 23: Pj1000-Light
19 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light menu 8 iic i 2 c address setting. The i 2 cnetworkaddressbecomessignificantwhen the exciter is connected in an rvr transmission system that uses this protocol. Do not change it unless strictly required. 5.4.6 version menu (vrs) this screen holds m...
Page 24: Pj1000-Light
20 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 6. Front and rear panel description this section describes the components found on the front and rear panel of pj1000-light. 6.1 front panel figure 6.1 [1] on greenled-turnsonwhenamplifierispoweredon. [2] fault/lock red led - turns on when machine...
Page 25: Pj1000-Light
21 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 6.2 rear panel figure 6.2 [1] r.F. Test output with level -60 db lower than output power level, suitable for modulation monitoring. Not suitable for spectrum analysis. [2] gsm slot-in reserved for future implementations [3] gsm ant reserved for fu...
Page 26: Pj1000-Light
22 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 6.3 connectors description 6.3.1 service ( for factory setting purposes only) type: female db9 1 nc 2 tx_d 3 rx_d 4 internally connected to 6 5 gnd 6 internally connected to 4 7 internally connected to 8 8 internally connected to 7 9 nc 6.3.2 left...
Page 27: Pj1000-Light
23 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 7. Technicalspecifications 7.1 mechanical characteristics panel size 483 mm (19”) x 132.5 mm (3 he) depth 550 mm weight approx. 31 kg working temperature -10 °c ÷ 50 °c, without condensing 7.2 electrical characteristics general rf output power 0-1...
Page 28: Pj1000-Light
24 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light remote connections interlock in bnc type female: by grounding the central conductor the transmitter is forced to stand- by mode. Ponendo a massa il conduttore centrale il trasmettitore viene forzato in modo stand-by interlock out bnc type female: ...
Page 29: Pj1000-Light
25 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 8. Operating principles figure 8.1 below provides an overview of pj1000-light modules and connections. Figure 8.1 following is a brief description of the different module functions; all diagrams and board layout diagrams are included in the “techn...
Page 30: Pj1000-Light
26 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 8.1.1 mains power supply pulse protection (slsrgprpj1km) thismoduleisenclosedinasealedmetalcase(seefigure9.1-item[8]);itfeatures twoexternallymountedmainsfuses(figure6.2-[7]and[20])andaccommodates a bank of surge arresters that protect the machine...
Page 31: Pj1000-Light
27 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light • regulated power set to 0 watt using the edit mode (menu 2, see chapter 5.2); • an alarm or fault condition has occurred (see chapter 5.3.4). 8.2 interface board (sl012in1001) this board performs the following tasks: • it uses ac voltage from tra...
Page 32: Pj1000-Light
28 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 8.5 poweramplifier the rf power amplification section consists in three power modules coupled through a wilkinson splitter and combiner using strip-line technology. Each rf module (code sl010rf2001) provides 350 w rated power using a single active...
Page 33: Pj1000-Light
29 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 8.7 bias board (slbias1k3u-2) the main purpose of this board is to control and correct the bias voltage of the rf amplificationsectionmosfets. It also provides a measure of the total current absorbed by the rf modules and incorporates a dedicated ...
Page 34: Pj1000-Light
30 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 9. Identificationandaccesstothemodules the pj1000-light is made up of various modules linked to each other through connectors so as to make maintenance and any required module replacement easier. 9.1 top view thefigurebelowshowstheequipmenttopview...
Page 35: Pj1000-Light
31 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light 9.2 bottom view thefigure9.2showstheequipmentbottomviewwiththevariouscomponents pointed out. Figure 9.2 [1] filter board (slfilpspj1kc) [2] ps led board (slledpstex1k) [3] interface board (sl012in1001) [4] tr1 transformer (trftex1000t) [5] telemet...
Page 36: Pj1000-Light
32 / 32 user manual rev. 1.1 - 12/12/05 pj1000-light this page was intentionally left blank.