R.V.R. Electronica PJ1000-LIGHT User Manual - Pj1000-Light
14 / 32
User Manual
Rev. 1.1 - 12/12/05
PJ1000-LIGHT
To gain access to a submenu, select menu name (name is highlighted by cursor)
using button or and press the
ENTER button (chap. 6.1 - [9]).
Press
ESC again (chap. 6.1 - [6]) to return to the default menu (menu 1).
5.4.1 Operation Menu (Fnc)
5.4.1 Operation Menu (Fnc)
In this menu, you can set
power output On/Off, toggle between “Local” or “Remote”
control mode and set the
Forward Power Good (PgD) threshold rate.
To edit an item, highlight the appropriate line using the UP and DOWN buttons
and then press and hold the
ENTER button (chap. 6.1 - [9]) until the command is
accepted. This way, Pwr setting is toggled between On and Off and Mod setting is
toggled between “x1” and “x10”. To edit the Power Good rate, simply select item
“PgD” and edit its value using buttons and ;finally,press
ENTER toconfirm
(chap. 6.1 - [9]).
Menu 4
Pwr
Enables(ON)ordisables(OFF)amplifierpoweroutput.
Loc
Modifiesmachineoperation.IntheLOCALmode,themachinecanread
and modify its operating parameters through the navigation keys and the
managementfirmware,whereasallothersourcesarelockedout.Inthe
REMOTE mode, the machine can only read its operating parameters;
parametersaremodifiedbasedonthecommandsreceivedfromother
connected telemetry systems.
PgD
ModifiesPowerGood(forwardpower)threshold.ThePowerGoodrate
is a percent of machine rated power (1000 W), not of forward output
power. This means that this threshold set at 50% will give 500 W
regardless of set power level. The Power Good feature enables output
power control and reporting. When output power drops below set Power
Good threshold, the machine changes the state of pin [7] of the DB15
“Remote”connectorlocatedontherearpanel(figure6.2-[16]).