RAB AL Installation Instructions - page 2
AL
TM
AREA LIGHT INSTALLATION INSTRUCTIONS
®
Page 2
MOUNTING (1) AL fIXTURE
DIRECTLy TO POLE
Fixed Arm mounting directly to 4” or larger square steel
pole. Note
Arm Orientation detail on first page.
Loosen (4) door screws, open fixture. Remove
ballast cover.
Insert
Threaded Rods into the pole and thread into
the
Bolster Plate.
Feed wires from fixture through
Gasket, Arm and
2nd
Gasket and into pole. Make connections and
knot wires as a strain relief. Replace pole cap.
Line up extrusion slots with the
Threaded Rods and
slide
Arm and fixture on Threaded Rods.
Place flat washer, lock washer and nut on the
Threaded Rods inside the fixture and tighten
securely.
1.
2.
3.
4.
5.
Bolster
Plate
Gaskets (2)
Arm
Threaded
Rods
MOUNTING (2) AL fIXTURES
AT 90° DIRECTLy TO POLE
Fixed Arm direct pole mounting of 2 fixtures at 90 de-
grees as shown below.
See steps 1-5 in “
MOUNTING () AL FIXTURE
DIRECTLY TO POLE” section. Follow for each fixture
MOUNTING (2) AL fIXTURES
AT 180° DIRECTLy TO POLE
Fixed Arm direct pole mounting of 2 fixtures at 180 de-
grees as shown below.
See steps 1-5 in “
MOUNTING () AL FIXTURE
DIRECTLY TO POLE” section. Follow for each fixture
MOUNTING (3) AL fIXTURES
DIRECTLy TO POLE
Fixed Arm direct pole mounting of 3 fixtures.
See steps 1-5 in “
MOUNTING () AL FIXTURE
DIRECTLY TO POLE” section. Follow for each fixture
MOUNTING (4) AL fIXTURES
DIRECTLy TO POLE
Fixed Arm direct pole mounting of 4 fixtures.
See steps 1-5 in “
MOUNTING () AL FIXTURE
DIRECTLY TO POLE” section. Follow for each fixture