Radwin 5000 HPMP User Manual

Other manuals for 5000 HPMP: User manual, User Manual, User manual
Manual is about: 5000 series POINT TO MULTIPOINT BROADBAND WIRELESS

Summary of 5000 HPMP

  • Page 1

    Radwin 5000 hpmp point to multipoint broadband wireless user manual release 3.2.00 um 5000-3200/08.11.

  • Page 2

    Radwin 5000 hpmp user manual release 3.2.00 i radwin 5000 hpmp user manual notice this manual contains information that is proprietary to radwin ltd. (radwin hereafter). No part of this publication may be reproduced in any form whatsoever without prior written approval by radwin. Right, title and in...

  • Page 3: Radwin Worldwide Offices

    Radwin 5000 hpmp user manual release 3.2.00 ii radwin worldwide offices corporate and emea regional headquarters corporate and emea headquarters 27 habarzel street tel aviv, 69710 israel tel: +972.3.766.2900 fax: +972.3.766.2902 email: sales@radwin.Com north america regional headquarters 900 corpora...

  • Page 4

    Radwin 5000 hpmp user manual release 3.2.00 iii regulatory compliance general note this system has achieved type approval in various countries around the world. This means that the system has been tested against various local technical regulations and found to comply. The frequency bands in which th...

  • Page 5

    Radwin 5000 hpmp user manual release 3.2.00 iv indoor units comply with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) these devices may not cause harmful interference. (2) these devices must accept any interference received, including interference that may cause...

  • Page 6

    Radwin 5000 hpmp user manual release 3.2.00 v brief table of contents part 1: basic installation chapter 1 introduction chapter 2 site preparation chapter 3 hardware installation part 2: sector installation chapter 4 getting started with the radwin manager chapter 5 installing the sector part 3: sec...

  • Page 7

    Radwin 5000 hpmp user manual release 3.2.00 vi full table of contents part 1: basic installation chapter 1 introduction welcome to radwin 5000 hpmp!...............................................................1-1 radwin 5000 hpmp highlights.............................................................

  • Page 8

    Radwin 5000 hpmp user manual release 3.2.00 vii chapter 4 getting started with the radwin manager what we will do here...................................................................................4-1 installing the radwin manager application ..................................................4-1...

  • Page 9

    Radwin 5000 hpmp user manual release 3.2.00 viii inventory ................................................................................................6-9 security ................................................................................................ 6-10 date and time ...................

  • Page 10

    Radwin 5000 hpmp user manual release 3.2.00 ix scope of this chapter ..................................................................................9-1 what is hub site synchronization?...............................................................9-1 hardware installation ..........................

  • Page 11

    Radwin 5000 hpmp user manual release 3.2.00 x chapter 14 fcc/ic dfs considerations fcc 5.4ghz device registration ................................................................. 14-1 registering the device ............................................................................... 14-1 tdwr ta...

  • Page 12

    Radwin 5000 hpmp user manual release 3.2.00 xi prerequisites ............................................................................................. 20-3 hardware .............................................................................................. 20-3 software .........................

  • Page 13

    Radwin 5000 hpmp user manual release 3.2.00 xii considerations for changing antenna parameters ..........................................E-3 appendix f regional notice: french canadian procédures de sécurité ................................................................................ F-1 général...

  • Page 14

    Radwin 5000 hpmp user manual release 3.2.00 xiii list of figures f igure 1-1 s ingle s ector b ase s tation ..............................................................1-3 f igure 1-2 s mall form factor antenna in connectorized odu .............................1-3 f igure 1-3 h igh gain integrated...

  • Page 15

    Radwin 5000 hpmp user manual release 3.2.00 xiv f igure 6-13 hsu c onfiguration - s etting antenna type and parameters ............. 6-22 f igure 6-14 hsu c onfiguration - ip addresses ................................................ 6-23 f igure 6-15 u nit 10.101 is down and unit 10.102 is availabl...

  • Page 16

    Radwin 5000 hpmp user manual release 3.2.00 xv f igure 16-1 l arge c lamp ................................................................................ 16-1 f igure 16-2 s mall c lamp ................................................................................ 16-1 f igure 16-3 a rm ............

  • Page 17

    Radwin 5000 hpmp user manual release 3.2.00 xvi list of tables t able 4-1 pc r equirements for the radwin m anager a pplication ......................4-1 t able 4-2 p reconfigured setup .........................................................................4-3 t able 4-3 u ser types , default pass...

  • Page 18: Part 1: Basic Installation

    Radwin 5000 hpmp point to multipoint broadband wireless user manual release 3.2.00 part 1: basic installation um 5000-3200/08.11.

  • Page 19: Chapter 1

    Radwin 5000 hpmp user manual release 3.2.00 1-1 chapter 1 introduction welcome to radwin 5000 hpmp! Radwin 5000 hpmp delivers up to 200mbps and is the ideal choice for last mile enterprise connectivity and high-end applications that demand assured performance with guaranteed bandwidth per subscriber...

  • Page 20: Some Terminology

    Some terminology chapter 1 radwin 5000 hpmp user manual release 3.2.00 1-2 • qos support • spectrum view • support for 3.3, 3.8 and 2.5 ghz bands some terminology a point to multipoint network is typically abbreviated to ptmp. The ptmp networks described in this manual are of course, radio links. A ...

  • Page 21

    Radwin 5000 hpmp components chapter 1 radwin 5000 hpmp user manual release 3.2.00 1-3 • common rnms radwin 5000 hpmp components radwin 5000 hbs high capacity base station the hbs consists of radwin 5000 hbs hbs odu, a sector dual- pole antenna and a poe device, which provides a lan interface to user...

  • Page 22: The Radwin Manager

    The radwin manager chapter 1 radwin 5000 hpmp user manual release 3.2.00 1-4 the radwin manager the radwin manager is an snmp-based management application which manages a com- plete sector over a single ip address. It can also manage hsus separately. The intuitive, easy-to-use radwin manager has a g...

  • Page 23

    Viewing and printing chapter 1 radwin 5000 hpmp user manual release 3.2.00 1-5 viewing and printing this manual is optimized for viewing online as a pdf file. To this end it uses an 11 point tahoma typeface for main text. Tables for most part, use 7 or 8 point fonts. Here are a few pointers for hard...

  • Page 24: Chapter 2

    Radwin 5000 hpmp user manual release 3.2.00 2-1 chapter 2 site preparation planning the sector site overview sector site planning consists of a set of surveys, which must be carried out before any equip- ment is deployed. If for some reason, the outcome of any of these surveys is negative, hbs or hs...

  • Page 25: Stage 1: Preliminary Survey

    Stage 1: preliminary survey chapter 2 radwin 5000 hpmp user manual release 3.2.00 2-2 • link budget calculator and/or radio planner stage 2: physical survey • 100 meter tape measure • ohmmeter, to check ground connection • binoculars • map • digital camera • paper, pencil, and a clipboard • gps devi...

  • Page 26: Stage 2: Physical Survey

    Stage 2: physical survey chapter 2 radwin 5000 hpmp user manual release 3.2.00 2-3 stage 2: physical survey the physical site survey reviews the environment of the proposed installation location, to ensure that the sector sites are suitable for the wireless network. The results of the physical site ...

  • Page 27: Stage 3: Rf Survey

    Additional indoor site requirements chapter 2 radwin 5000 hpmp user manual release 3.2.00 2-4 additional indoor site requirements the ambient operating temperature should be 0 to 50°c (32 to 122 °f) at a humidity of up to 90%, non condensing stage 3: rf survey the rf survey examines the wireless env...

  • Page 28: Chapter 3

    Radwin 5000 hpmp user manual release 3.2.00 3-1 chapter 3 hardware installation this chapter sets out the requirements and procedures for the hardware installation and alignment of a radwin 5000 hpmp sector in accordance with the prior planning as set out in chapter 2 . It is intended to guide quali...

  • Page 29: Package Contents

    Protection against lightning chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-2 outdoor units, masts, lead-in wiring and discharge units. It also lays down the size of grounding conductors and connection requirements for grounding electrodes. Radwin 5000 hpmp odus must be grounded to a protec...

  • Page 30

    Hbs and hsu odu package contents chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-3 • link budget calculator • label showing the mac address and the alternative community string. The label is self-adhesive. You should keep this label safe • cable glands (to be used with the odu-poe cable) fig...

  • Page 31

    External antenna package contents chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-4 • connectorized odu this odu has 2xn-type connectors for connecting an external antenna • hsu only - sff (connectorized) odu the sff odu is slightly “fatter” and heavier than a regular connectorized odu since...

  • Page 32

    Power over ethernet (poe) devices chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-5 • mounting kit power over ethernet (poe) devices gbe poe radwin’s gigabit power over ethernet (gbe poe) device provides data and power to radwin 5000 5000 outdoor units. The poe device is available with a var...

  • Page 33

    Hub site synchronization (hss) unit chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-6 outdoor (ruggedized) dc poe device this unit may be used or both the hbs and the hsus. It will not support gigabit performance on the hbs. Figure 3-7: ruggedized dc-poe device: input is -20 to -60 vdc (sing...

  • Page 34

    Additional tools and materials required chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-7 the gsu is connected to the hss unit using a standard hss cable. It synchronizes the trans- mission timing of multiple hub-sites to the same clock source thus eliminating self interfer- ence (see chapte...

  • Page 35

    Hardware installation sequence chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-8 • odu-poe cable (outdoor class, cat-5e, 4 twisted pairs, 24awg), up to 100 m. For 100baset connection. For a 1000baset connection (hbs only) use an odu-poe cable no longer than 75m. • a crossed ethernet lan cabl...

  • Page 36: Outdoor Installation

    Outdoor installation chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-9 figure 3-10: typical hsu installation with external antenna the hbs installation differs only in the antenna type: it uses a sector antenna. The installation steps are detailed in the following sections. Outdoor installat...

  • Page 37

    Mounting external antennas chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-10 into the unit causing damage.) it is possible to mount an odu horizontally. See chapter 16 for details. 3. Refer also to chapter 16 for detailed odu mounting kit contents and schematics. Mounting external antennas ...

  • Page 38: Aligning Hsus to An Hbs

    Installing a sector using poe devices chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-11 2. Connect the lightning protection device to the odu (see chapter 17 ). 3. Attach the odu-poe cable to the odu rj-45 connector (see appendix b for the connector pinout) 4. Screw in the cable glands to e...

  • Page 39

    Aligning hsus to an hbs chapter 3 radwin 5000 hpmp user manual release 3.2.00 3-12 the details are described in the next two steps. “antenna” refers both to an external antenna and an integrated antenna. The two steps should be carried out for each hsu in the sector. 5. Make a horizontal sweep of 18...

  • Page 40: Part 2: Sector Installation

    Radwin 5000 hpmp point to multipoint broadband wireless user manual release 3.2.00 part 2: sector installation um 5000-3200/08.11.

  • Page 41: Chapter 4

    Radwin 5000 hpmp user manual release 3.2.00 4-1 chapter 4 getting started with the radwin manager what we will do here this chapter is a quick “hands-on” tour of a running sector. We show you how to install the radwin manager software on your managing pc, connect it to an operating base station and ...

  • Page 42

    Installing the software chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-2 • any modern web browser to view additional material, use the web interface or get help from the radwin web site. Installing the software any pc running the radwin manager application can be used to configure a radwin ...

  • Page 43

    Getting started with the radwin manager chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-3 getting started with the radwin manager we will look at a preconfigured sector, setup as follows: to start the radwin manager: 1. Connect the managing computer to the hbs poe lan port. 2. Check that you...

  • Page 44

    The radwin manager log-on concept chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-4 you should see something like this: figure 4-1: pinging the base station. Any other response from ping means that the hbs odu is not responding. Check your ethernet connection and that both the poe and odu ar...

  • Page 45

    The radwin manager log-on concept chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-5 figure 4-3: extended log-on window at the user type field, click the list button: figure 4-4: log on window exposing the user types. There are three user types: • an observer has read-only access to the secto...

  • Page 46

    The radwin manager log-on concept chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-6 the following table summarizes these options: the network manager should change the default passwords as soon as possible. Continuing the log-on procedure: 5. If your user type is not operator, then choose it...

  • Page 47: Log-On Errors and Cautions

    Log-on errors and cautions chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-7 figure 4-5: opening radwin manager window - hbs log-on errors and cautions unsupported device attempting to connect to an unsupported device on an otherwise valid ip address (for exam- ple, a lan printer) will resul...

  • Page 48

    Incorrect password chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-8 figure 4-7: unreachable device message incorrect password if you type an incorrect password in the login window, the follwing message will be dis- played: figure 4-8: invalid user type or password invalid read/write communi...

  • Page 49

    Hbs main button menu chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-9 hbs main button menu figure 4-9: hbs main button menu sector status panel the sector level information is shown here. There is nothing that can be changed for an active sector. The parameters are set before the base stati...

  • Page 50

    Base station panel chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-10 figure 4-11: base station detail panel the tx ratio shows the allocation of throughput between downlink and uplink traffic at the hbs. Here it is set to 70% downlink and 30% uplink. The tx ratio is not only sector-wide: if...

  • Page 51

    Hbs events log chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-11 clicking the activate button initiates an activation wizard. The activate button in the title bar is hidden, leaving it looking like this: the activation process is covered in detail in chapter 5 . At any time, the current sta...

  • Page 52

    Hbs main window - hsus panel chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-12 hbs main window - hsus panel figure 4-13: hbs main window (reduced) - up to 16 hsus if you have a large number of hsus in the sector, it may be helpful to filter the display. You have the following choices: the f...

  • Page 53

    Hbs main window - hsus panel chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-13 if you mouse-over the colored rss area, you will receive a tool tip telling you that rss for radio 1 is higher than for radio 2, or something similar. Figure 4-15: hsu display - detail the little ball on the top ...

  • Page 54

    Hbs main window - hsus panel chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-14 figure 4-16: hsu display - context menu (right click) to switch to a list display, click the top right list button: figure 4-17: hsu on hbs display - extract. Scroll right for more hsu fields the button bar in fi...

  • Page 55: Logging On to An Hsu

    Exploring the radwin manager main window - hsu chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-15 exploring the radwin manager main window - hsu you may log on to an hsu over the air from an hbs or by directly connecting a managing computer to the hsu whether through a switch or directly to ...

  • Page 56

    Logging on to an hsu chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-16 figure 4-19: opening radwin manager window - hsu.

  • Page 57

    Hsu main button menu chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-17 hsu main button menu the hsu main button menu is similar to the hbs main button menu. The only new item is in the configure button. Figure 4-20: hsu main button menu hsu link status table 4-8: hsu main button bar functio...

  • Page 58

    Hsu events log chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-18 hsu events log the hsu events display is functionally identical to that of the hbs. Hsu link performance for convenience the hsu link performance panel shows the same fields as in figure 4-15 . For convenience we also display ...

  • Page 59

    Monitor chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-19 monitor the monitor file contains a vast amount of information and can become inordinately large very quickly. You should therefore choose a longer sampling interval if you intend to store this information for a lengthy duration. For...

  • Page 60

    Events chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-20 events here you may choose your own color coding for the recent event display (see chapter 8 ). You may also choose a location and file name for the events log for storage. These settings are again, per hbs or hsu. To avoid over-writi...

  • Page 61: What Comes Next?

    Advanced chapter 4 radwin 5000 hpmp user manual release 3.2.00 4-21 advanced many alert messages in the radwin manager have an option of the form “do not show this message again”. These alert messages can be reverted to their default state (shown) by click- ing the restore alerts button. You will be...

  • Page 62: Chapter 5

    Radwin 5000 hpmp user manual release 3.2.00 5-1 chapter 5 installing the sector scope of this chapter chapter 4 , offered an overview of a running sector as motivation for the technical installa- tion details set out below. Assuming that the sector equipment is in place as described in earlier chapt...

  • Page 63: Workflow

    Workflow chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-2 receives at least one time slot. To disable an hsu you must deregister it. (a suspend mech- anism is also available, to suspend service on an hsu for a limited period.) for each registered hsu, you can set separately, the uplink and ...

  • Page 64

    Default radwin 5000 hpmp settings chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-3 for convenience, we repeat the table of parameters used in our demonstration sector. Param- eters not listed are left at their default values. Hsu ip address 10.0.0.120 net mask 255.0.0.0 default gateway 0.0....

  • Page 65

    Configuring the sector out of the box - ip addresses chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-4 configuring the sector out of the box - ip addresses the default log-on ip address for all odus in the sector is the same: 10.0.0.120, subnet mask 255.0.0.0 and default gateway 0.0.0.0. To ...

  • Page 66

    Configuring the sector out of the box - ip addresses chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-5 figure 5-2: logging on with local connection here is the main display: warning • the local connection method uses broadcast packets to “discover” the attached odu • if you log on using loca...

  • Page 67

    Configuring the sector out of the box - ip addresses chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-6 figure 5-3: main window for un-configured hbs odu notice the red icon on the top left corner of the window. It will change to green as soon as the hbs is configured and activated. To pre-co...

  • Page 68

    Configuring the sector out of the box - ip addresses chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-7 figure 5-4: site configuration prior to definition 2. Click the management tab..

  • Page 69

    Configuring the sector out of the box - ip addresses chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-8 figure 5-5: definition of ip address done here 3. Enter the ip address, subnet mask and default gateway and then click ok. You are offered a warning: 4. Click yes. The dialog is dismissed a...

  • Page 70: Activating The Hbs

    Activating the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-9 activating the hbs with all the units in place, log on to the hbs using the new ip address. The main window looks like this: figure 5-6: hbs ready for configuration and activation activating the hbs enables it to be discove...

  • Page 71

    Activating the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-10 2. Click next: enter the sector id, name and location. All fields are mandatory. Here are entries in accordance with table 5-2 :.

  • Page 72

    Activating the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-11 choose your sector id it carefully particularly if you are using collocated hbss for extra coverage. The sector name and location are convenience items but should be chosen to ensure that the sector is documented and easil...

  • Page 73

    Activating the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-12 here you may enter the ip details if didn’t do it earlier. Click next. 4. The next window is used to set the frequency and channels. The default frequency for the installed band is shown. Click the right hand selector whee...

  • Page 74

    Activating the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-13 choosing other enables you to move up and down by increments of 5 mhz: 5. Choose the required channel bandwidth:.

  • Page 75

    Activating the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-14 6. To use acs, check the automatic channel selection box: you can perform a customized channel selection or click select all to check all the channel boxes as shown:” note if your hardware supports 200 mbps net aggregate c...

  • Page 76

    Activating the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-15 7. Click next. The antenna type and tx power window is presented: the choice of tx power, antenna gain and cable loss (between the radio and the antenna) determines the eirp and is affected by such considerations as radio ...

  • Page 77

    Activating the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-16 8. The summary window of the wizard is displayed. Check that all information showed is correct and click activate. After a few moments the sector hsus will be displayed in the manager hsu panel. Warning when setting requir...

  • Page 78

    Activating the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-17 figure 5-7: the sector showing hsus configured but unregistered at this point, the hsus can communicate for management but not for service. You may see that an hsus has its rss entry shaded yellow. Shading of this type ind...

  • Page 79

    Pre-configuring the hsus for service chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-18 pre-configuring the hsus for service the hsu activities described in this section, may be carried out any time - regardless of whether or not the hsu is registered for service or not. These activities inc...

  • Page 80

    Pre-configuration from the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-19 location is a site name - typically a building or tower name. Contact is the contact person at that location and name is the contact location. It might be just a tele- phone number. Here are our entries:.

  • Page 81

    Pre-configuration from the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-20 3. An additional parameter, which might be adjusted here, is the hsu tx power (possi- bly required by regulations). Click tx & antenna. The following dialog is displayed: set the antenna type, required tx power...

  • Page 82

    Pre-configuration from the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-21 set the hsu ip address, subnet mask and default gateway. You may defer the trap destinations, vlan and protocol settings for now.Here are our settings for this hsu: 5. Click ok. You will be offered a cautionary...

  • Page 83

    Pre-configuring from a direct link chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-22 click yes. 6. Return to the hsu context menu ( figure 5-8 ). Click reset. The newly entered parameters for the hsu are now displayed: 7. Repeat the last six steps for each hsu in the sector. Pre-configuring...

  • Page 84

    Pre-configuring from a direct link chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-23 2. Click the (top left hand) configure button..

  • Page 85

    Pre-configuring from a direct link chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-24 3. The display and those which follow are almost identical to the corresponding hbs configuration panels. Enter the name, contact and location fields as before. 4. Leave air interface and tx & antenna for n...

  • Page 86

    The final outcome chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-25 the final outcome here is the outcome for our example, whichever method used: you may now carry out any other adjustments to hs_10.101 either from the hbs or by direct connection. Notice that as we did for hsu_10.102, we ad...

  • Page 87

    Registering the hsus for service chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-26 as a partial alternative method, you may enter the name and location fields during regis- tration. Registering the hsus for service we continue our illustration using hsu at hsu_10.102. To register an hsu for...

  • Page 88

    Registering the hsus for service chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-27 3. You may edit or add the site name and location. 4. If you are using dual antennas, you may check the mimo or diversity antenna mode. The choice is hsu specific. For further details about mimo/diversity ant...

  • Page 89

    Registering the hsus for service chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-28 figure 5-9: hsu registration dialog 6. Click the number of time slots to be allocated to the hsu. The register button is now enabled. 7. Use the sliders to set uplink and downlink mir. You may defer this and ...

  • Page 90

    Registering the hsus for service chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-29 observe that the registered hsu led is now green and that the time slots bar on the left reflects the proportion of time slots allocated. 9. Repeat steps 1 to 8 for other hsus. Here is the result for our exam...

  • Page 91

    Choosing diversity antenna mode during registration chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-30 figure 5-10: fully functional sector choosing diversity antenna mode during registration suppose that in figure 5-9 for hsu_10.102 we had chosen diversity mode, the outcome would look like ...

  • Page 92: Deactivating The Hbs

    Deactivating the hbs chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-31 deactivating the hbs from the hbs button bar, click the right hand button followed by deactivate. You ware offered a cautionary message: if you proceed, the hbs display will change to reflect the deactivated state: dereg...

  • Page 93

    Where has my hsu gone? Chapter 5 radwin 5000 hpmp user manual release 3.2.00 5-32 be “forced” across to another hbs by changing its sector id to that of the required hbs. The method for doing this is covered in chapter 7 ..

  • Page 94: Part 3: Sector Management

    Radwin 5000 hpmp point to multipoint broadband wireless user manual release 3.2.00 part 3: sector management um 5000-3200/08.11.

  • Page 95: Chapter 6

    Radwin 5000 hpmp user manual release 3.2.00 6-1 chapter 6 managing the sector scope of this chapter this chapter deals with managing the sector from the hbs. It covers hbs configuration and hsu configuration from the hbs. Hsu direct or over-the-air configuration is a little different and is covered ...

  • Page 96

    System chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-2 system these items are convenience fields. Name and location are typically entered during hbs activation..

  • Page 97

    Air interface chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-3 air interface this panel has the same functionality as the corresponding window in the activation wizard (see chapter 5 ). Changing the sector id will “percolate” to all registered hsus. It will of course, be “picked up” by newl...

  • Page 98

    Tx and antenna chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-4 tx and antenna this tab is available for both the hbs and hsus. It has the same meaning in both cases. For the hbs, changes made here may affect link quality and in the case of antenna type, cause a sector re-sync. Changing the...

  • Page 99

    Hub site sync [hss] chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-5 hub site sync [hss] the external pulses detected in this example, come from a collocated radwin 2000 odu configured as hub sync master. (a winlink 1000 would have done just as well.) to enable hss, check the enabled check ...

  • Page 100

    Management chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-6 management if you set the ip and related addresses correctly, there should be little to change here. The three sub-windows, trap destinations, vlan management and protocol dialogs are generic to the hbs nad the hsus (direct or over...

  • Page 101

    Management chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-7 trap destinations enter the trap destinations. They could include the ip address of the managing computer. The events log will be stored at the addresses chosen. Vlan for management management vlan configuration figure 6-1: vlan fo...

  • Page 102

    Management chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-8 traffic sent from the odu to the managing computer. Using vlan for management traffic affects all types of management connections (local, network and over the air). 3. Enter a priority number between 0 and 7. 4. Change the vlan id ...

  • Page 103

    Inventory chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-9 inventory you might like to capture or copy the information here: the inventory information will be required by customer support should you require assis- tance..

  • Page 104

    Security chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-10 security this section applies to both the hbs and hsus unless stated otherwise. Figure 6-2: sector security settings the security dialog enables you to change the link password and the snmp community strings. Changing the link passw...

  • Page 105

    Security chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-11 the change link password dialog box opens. Figure 6-3: change link password dialog box 2. Enter the current link password (the default link password for a new odu is wire- less-p2mp). If you have forgotten the link password, click t...

  • Page 106

    Security chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-12 7. Click ok at the password changed success message. Radwin manager community strings the odu communicates with the radwin manager using snmpv1 protocol. The protocol defines three types of communities: • read-only for retrieving in...

  • Page 107

    Security chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-13 figure 6-5: changing the community string forgotten community string if the read-write community string is unknown, an alternative community key can be used. The alternative community key is unique per odu and can be used only to ch...

  • Page 108

    Date and time chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-14 figure 6-6: alternative community dialog box date and time setting the date and time the odu maintains a date and time. The date and time should be synchronized with any net- work time protocol (ntp) version 3 compatible server...

  • Page 109

    Date and time chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-15 figure 6-7: date and time configuration 3. If entering an ip address for the ntp server, click clear, and then enter the new address. 4. Set your site offset value in minutes ahead or behind gmt 1 . 5. To manually set the date ...

  • Page 110

    Ethernet service configuration chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-16 ethernet service configuration figure 6-9: setting ethernet services hbs aging time the hbs works in bridge mode. In bridge mode the odu performs both learning and aging, forwarding only relevant packets over t...

  • Page 111

    Ethernet service configuration chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-17 . An auto detect feature is provided, whereby the line speed and duplex mode are detected automatically using auto-negotiation. Use manual configuration when attached external equipment does not support auto-ne...

  • Page 112

    Operations chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-18 you may wish to un-check this item if your application is based on multicast/broadcast pack- ets - for example, video surveillance using multicast downlink, or video conferencing using multicast uplink. Operations this section app...

  • Page 113: Hsu Connection Table

    Advanced: false radar mitigation for hbs chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-19 license activation you may add additional bands using the license activation facility. Additional bands (if avail- able) are obtained using the change band function, described below. For a single band...

  • Page 114

    Configuring an hsu from the hbs main window chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-20 the following table is displayed: figure 6-11: hsu intercommunication the green shaded squares show intercommunicating elements within the sector. Mng refers to management traffic which should alwa...

  • Page 115

    System chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-21 recall that the buzzer tone is used for hsu antenna alignment. The refresh button restores the current window to its previous state abandoning any changes you made, provided that you did not click apply or ok. We will work through eac...

  • Page 116

    Tx & antenna chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-22 tx & antenna figure 6-13: hsu configuration - setting antenna type and parameters the remarks about changing the hbs parameters also apply here. Changing the antenna type will cause a re-sync between the hsu and the hbs..

  • Page 117

    Management chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-23 management figure 6-14: hsu configuration - ip addresses the functionality is identical as that for the hbs..

  • Page 118

    Inventory chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-24 inventory you should note the details for each hsu..

  • Page 119

    Security chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-25 security you may change the snmp community strings only for the hsu from here. You cannot change the link password from an hsu..

  • Page 120

    Date & time chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-26 date & time the functionality is identical as that for the hbs..

  • Page 121

    Ethernet chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-27 ethernet ethernet configuration for an hsu follows the same general pattern as the corresponding tab for the hbs but with important differences. Ethernet ports configuration this item is same for hsus and the hbs. See page 6-16 . Ma...

  • Page 122

    Operations chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-28 operations this functionality is identical to that for the hbs. Advanced: false radar mitigation this tab is only visible if • you are using a regulation requiring radar channel avoidance and.

  • Page 123: Replacing An Hsu

    Replacing an hsu chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-29 • you are logged on as installer for this release, this feature for hsus, is relevant to the 5.3 ghz etsi and the 5.4 ghz fcc/ ic bands. Configuration of false radar mitigation is covered in chapter 13 . Replacing an hsu a d...

  • Page 124

    Replacing an hsu chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-30 3. Select the required unit by clicking on it. 4. Oops! We cannot continue - the ok button is disabled. Mouse-over the left hand information button to obtain a tool-tip advisory notice: 5. Cancel the current dialog and right...

  • Page 125

    Replacing an hsu chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-31 notice that although site 10.101 is down, it is still registered and its time slots are still reserved. 6. Repeat steps 1 to 3. Now the ok button is enabled: 7. Click ok. You are requested to accept your choice: 8. Click ok....

  • Page 126: Updating Hsu Services

    Updating hsu services chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-32 9. Again, click ok. Here then, is the final situation: updating hsu services choosing update services from an hsu context menu or clicking from the hsu button bar opens the following window: you may use this to switch t...

  • Page 127: Suspending An Hsu

    Suspending an hsu chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-33 suspending an hsu you may break the link (cause a sync loss) to an un-registered hsu for a fixed amount of time. Here is the scenario: hsu 10.102 is not registered. To suspend an un-registered hsu: 1. Click suspend in its c...

  • Page 128

    Changing the sector band chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-34 to change the sector band: 1. Click change band. A list of available bands is displayed: figure 6-16: change or add bands 2. Select the required band and click ok. Notice that we have chosen the 5.820 ghz band. The s...

  • Page 129

    Changing the sector band chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-35 the foregoing applies to both regulated and unregulated bands. To obtain and install additional bands: 1. Make a list of odu serial numbers for all hbss and all hsus to receive additional bands. The list should be a ...

  • Page 130

    Changing the sector band chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-36 5. Fill out the requested details. Remember to terminate the dialog by clicking the get key button. 6. The results of your request will be displayed with further instructions, a few minutes later, you should receive ...

  • Page 132

    Telnet access to the hbs chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-38 supported hbs telnet commands are shown in table 6-1 to table 6-3 . Table 6-1: hbs telnet - display commands command explanation display inventory displays odu product name, name, location, hardware and software revi...

  • Page 133

    Telnet access to the hsu chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-39 telnet access to the hsu the procedure is the same as for the hbs. Figure 6-19: telnet management window - hsu supported hsu telnet commands are shown in table 6-4 to table 6-6 . Table 6-4: hsu telnet - display comma...

  • Page 134

    Telnet access to the hsu chapter 6 radwin 5000 hpmp user manual release 3.2.00 6-40 set writepw set the read-write access password (read-write community) set trappw set the trap community string set buzzer.

  • Page 135: Chapter 7

    Radwin 5000 hpmp user manual release 3.2.00 7-1 chapter 7 direct hsu configuration scope of this chapter direct management of an hsu may be carried out by a direct lan connection to a managing computer (on-site) or over-the-air (from the hbs site). There are several differences in the configuration ...

  • Page 136

    Configuring an hsu chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-2 figure 7-1: direct or over the air connection to a registered hsu for an unregistered hsu, the throughput (t-put) fields and the sector id field would be empty. If the hbs is deactivated, or the hsu is stand-alone you will ...

  • Page 137

    Configuration menu buttons chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-3 figure 7-2: direct connection to a stand-alone hsu in what follows, we configure a registered hsu unless specifically specified otherwise. Configuration menu buttons the backup and restore buttons have the same func...

  • Page 138

    System chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-4 system figure 7-3: hsu configuration window (direct) these items are convenience fields. They are typically entered before the sector is brought up..

  • Page 139

    Air interface chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-5 air interface figure 7-4: hsu configuration - air interface for registered hsu for a registered hsu this window is for information only. For an unregistered or unsynchro- nized hsu, the sector id field will be blank and editable...

  • Page 140

    Air interface chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-6 where has my hsu gone? Suppose that you installed two collocated hbss with contiguous sectors. It is possible that an hsu located close to the common sector boundary may “discover” the wrong hbs. A hsu can be “forced” across to ...

  • Page 141

    Tx & antenna chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-7 tx & antenna see page 6-22 ..

  • Page 142

    Management chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-8 management see page 6-23 ..

  • Page 143

    Inventory chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-9 inventory see page 6-24 ..

  • Page 144

    Security chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-10 security you may only change the snmp community strings over a direct or over-the-air connection. You can change the link password for an un-synchronized hsu. Otherwise the functionality is the same as in page 6-25 ..

  • Page 145

    Date & time chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-11 date & time see page 6-26 ..

  • Page 146

    Ethernet chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-12 ethernet this item is same for hsus and the hbs. See page 6-16 ..

  • Page 147

    Operations chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-13 operations see page 6-28 ..

  • Page 148

    Advanced chapter 7 radwin 5000 hpmp user manual release 3.2.00 7-14 advanced advanced: false radar mitigation this tab is only visible if • you are using a regulation requiring radar channel avoidance and • you are logged on as installer for this release, this feature for hsus, is relevant to the 5....

  • Page 149: Chapter 8

    Radwin 5000 hpmp user manual release 3.2.00 8-1 chapter 8 monitoring and diagnostics the radwin manager application enables you to monitor the sector, as well as perform basic diagnostic operations such as throughput testing. This chapter covers: • retrieving link information • throughput checking •...

  • Page 150

    Retrieving link information (get diagnostics) chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-2 to get diagnostics: 1. Click the get diagnostics button: figure 8-1: get diagnostics dialog box - hbs monitor detailed event data record active alarms active alarms are raised for any event affect...

  • Page 151

    Retrieving link information (get diagnostics) chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-3 figure 8-2: get diagnostics dialog box - hsu 2. Select or deselect the data options. If the file is to be sent to radwin customer sup- port leave all options checked. 3. Hbs only: choose hsus to b...

  • Page 152: Throughput Checking

    Throughput checking chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-4 the content of the diagnostics report is an aggregate of all the more specific reports discussed below. It is primarily intended for use by radwin customer support. Throughput checking in this mode, radwin 5000 hpmp estima...

  • Page 153: Recent Events

    Recent events chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-5 2. In either case, you are asked to enter the testing period: 3. Enter the required time and click ok to continue. The ethernet services area changes appearance and the estimated throughput is displayed: at the end of 30 seconds...

  • Page 154

    Recent events chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-6 you may filter the events shown by choosing all or internal. A full report may be seem by clicking recent events: figure 8-3: recent events: left- hbs, center hsu from hbs, right hsu direct in each case the report has the same f...

  • Page 155: Performance Monitoring

    Performance monitoring chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-7 the left button may be used to save the report to a file. Performance monitoring radwin 5000 hpmp performance monitoring constantly monitors traffic over the radio link and collects statistics data for the air interface...

  • Page 156

    Hbs chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-8 the on-screen and generated reports have the same general formats, but there are differ- ences in what is reported. Hbs the hbs performance monitoring window offers the following button menu: choose the data period required with the 15 mi...

  • Page 157

    Hbs chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-9 figure 8-6: hbs - performance monitoring report - valid data the meaning of the column headings is shown in the following table: data becomes invalidated following a reset. In the example below, the hbs was reset shortly after 11:00. All ...

  • Page 158

    Hsu chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-10 figure 8-7: hbs - performance monitoring report - showing invalid data use the save button to store the current data to file and the clear button to delete currently stored performance data. Hsu the performance monitoring window for the ...

  • Page 159

    Hsu chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-11 figure 8-8: hsu - performance monitoring report - both valid and invalid data (1 of 3) figure 8-9: hsu - performance monitoring report - both valid and invalid data (2 of 3) figure 8-10: hsu - performance monitoring report - both valid a...

  • Page 160

    More on the thresholds chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-12 the hsu report contains many more fields than the hbs. Here is their meaning:: as for the hbs, use the save button to store the current data to file and the clear button to delete currently stored performance data. Mor...

  • Page 161: Radwin Manager Traps

    Radwin manager traps chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-13 bber threshold the background block error ratio is measured as a percentage. The threshold can be set from 0.1% up to 50%. An 8% threshold is recommended. If there are no problems during the interval, then for that thres...

  • Page 162: Active Alarms

    Active alarms chapter 8 radwin 5000 hpmp user manual release 3.2.00 8-14 active alarms active alarms are raised for any event affecting availability or quality of service. The active alarms button, is available for the hbs and the hsus.Her is an example: current active alarms may be saved to a file....

  • Page 164: Part 4: Site Synchronization

    Radwin 5000 hpmp point to multipoint broadband wireless user manual release 3.2.00 part 4: site synchronization um 5000-3200/08.11.

  • Page 165: Chapter 9

    Radwin 5000 hpmp user manual release 3.2.00 9-1 chapter 9 hub site synchronization scope of this chapter this chapter is specific to collocating hbss. Should you require to collocate with other radio models, you should consult with radwin customer service. What is hub site synchronization? When seve...

  • Page 166

    What is hub site synchronization? Chapter 9 radwin 5000 hpmp user manual release 3.2.00 9-2 figure 9-1: interference caused by collocated units adding hss removes interference as shown in the next two figures: figure 9-2: collocated units using hub site synchronization (1) figure 9-3: collocated uni...

  • Page 167: Hardware Installation

    Hardware installation chapter 9 radwin 5000 hpmp user manual release 3.2.00 9-3 • hss client-continue transmission (hsc-ct): if the unit loses synchronization with the hss master, the link remains active. However, without synchronization pulses, it is possible that this unit will cause interference....

  • Page 168

    Using a single hss unit chapter 9 radwin 5000 hpmp user manual release 3.2.00 9-4 using a single hss unit figure 9-5: hss wiring schematic the wiring, as shown in figure 9-5 is self explanatory. The sync signal path is less self-evi- dent. If we set odu 1 (on sync 1) to hss master, then the sync sig...

  • Page 169

    Using more than one hss unit chapter 9 radwin 5000 hpmp user manual release 3.2.00 9-5 2. The next available sync port of the first hss unit should be connected to sync 10 of the second hss unit as shown in figure 9-7 . In the illustration, the next available port on the first hss unit is sync 6. 3....

  • Page 170: Radio Frame Pattern (Rfp)

    Odu/hss unit connection pinout chapter 9 radwin 5000 hpmp user manual release 3.2.00 9-6 condition 2: total hss cable length the total path of the hss sync pulse must not exceed 300m. This applies no matter how many hss units are used. To illustrate the method for calculating the sync pulse path len...

  • Page 171

    Without hss chapter 9 radwin 5000 hpmp user manual release 3.2.00 9-7 without hss when selecting ethernet services, the system automatically and transparently chooses the optimal rfp. Rfp and hss when hss is used, the rfp for the collocated radios must be selected manually. Radwin 5000 hpmp radios u...

  • Page 172: Sector Configuration and Hss

    Rfp: general radio frame pattern chapter 9 radwin 5000 hpmp user manual release 3.2.00 9-8 select the rfp that gives you the best fit or available for required system services and select the channel bandwidth accordingly. Rfp: general radio frame pattern when setting the rpf, the following considera...

  • Page 173

    Sector configuration and hss chapter 9 radwin 5000 hpmp user manual release 3.2.00 9-9 figure 9-10: hss settings window if you click the enabled box, the central display (with operational state opened) will look like this:.

  • Page 174

    Sector configuration and hss chapter 9 radwin 5000 hpmp user manual release 3.2.00 9-10 figure 9-11: setting hbs as hsm or hsc continue tx means that the hbs as a client to continue to work if there is no hsm pulse. If you select hub sync master and click apply, the display changes again: figure 9-1...

  • Page 175

    Sector configuration and hss chapter 9 radwin 5000 hpmp user manual release 3.2.00 9-11 the possible external pulses conditions are shown in the following table: table 9-6: external pulse status hss sync status meaning color code generating odu is hsm and generates the sync pulse green detected odu ...

  • Page 176: Chapter 10

    Radwin 5000 hpmp user manual release 3.2.00 10-1 chapter 10 using the radwin gsu what is it for the gps-based synchronization unit (gsu) is designed to handle inter-site interferences under large-scale deployment scenarios. The gsu is an outdoor unit consisting of a standard winlink 1000 enclosure, ...

  • Page 177

    Multiple distributed sites with communication chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-2 ted sit figure 10-1: gsu scenario - independent distributed sites multiple distributed sites with communication what happens if, in figure 10-1 , the gsu towers themselves have radios communicat...

  • Page 178: Gsu Redundancy

    Cascaded sites using shifted phase transmission chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-3 cascaded sites using shifted phase transmission the solution offered here is not a “universal cure”. The following conditions are necessary, but in any specific case may not be sufficient: • t...

  • Page 179: Gsu Kit Contents

    Gsu kit contents chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-4 figure 10-4: make the gsus the first two collocated units redundancy switching is completely transparent to the gsu-managed links. Gsu kit contents the gsu package includes: • 1 x gsu • 1 x mounting kit • 1 x gps antenna • ...

  • Page 180

    Preparing the gsu for use chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-5 figure 10-5: general gsu configuration in that respect, all of the considerations of chapter 3 , chapter 17 and chapter 18 of the use manual apply to the gsu. It may be configured using the regular radwin manager o...

  • Page 181

    Configuring the gsu chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-6 figure 10-6: gsu main widow at startup the top five items in the gsu monitor panel are taken from a satellite. The transmission phase may be normal as shown or shifted. It purpose, together with the tx ratio bar, will be...

  • Page 182

    Configuring the gsu chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-7 using site configuration for the gsu site configuration: system here is the opening window for site configuration: figure 10-7: site configuration: system it is similar to that of the winlink 1000..

  • Page 183

    Configuring the gsu chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-8 site configuration: gps sync unit this window is the main gsu configuration tool: figure 10-8: site configuration: gps sync unit 1. Setting the rfp for hss the gsu is automatically configured as hss master (hsm). If the ...

  • Page 184

    Configuring the gsu chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-9 the permitted rfps are also dependent on channel bandwidth and are color coded as fol- lows: there is a further restriction: if there are two distributed sites transmitting to each other, they must both use the same rfp....

  • Page 185

    Configuring the gsu chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-10 site configuration: management figure 10-9: site configuration: management here you set the gsu ip address, subnet mask and gateway. You also set trap addresses here. It is identical to the corresponding panel for winli...

  • Page 186

    Configuring the gsu chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-11 site configuration: inventory figure 10-10: site configuration: inventory site configuration: security you can only change the snmp community stings:.

  • Page 187

    Configuring the gsu chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-12 figure 10-11: site configuration: security site configuration: date and time odu recent events, alarms and traps are time-stamped from the time method chosen here (ntp, managing computer, odu default)..

  • Page 188

    Configuring the gsu chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-13 figure 10-12: setting the date and time for trap reporting site configuration: operations the only available action here is restore system defaults:.

  • Page 189

    Configuring the gsu chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-14 figure 10-13: site configuration: operations.

  • Page 190: Gsu Telnet Support

    Gsu preferences chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-15 gsu preferences the preferences window adds a new tab for the gsu: figure 10-14: site configuration: operations you may chose the units for latitude/longitude coordinates. Gsu monitoring and diagnostics the monitoring and d...

  • Page 191

    Software update for gsus chapter 10 radwin 5000 hpmp user manual release 3.2.00 10-16 display ratio display tx_phase display gpsinfo the last one display gpsinfo, is the most interesting: admin@10.107.2.20-> display gpsinfo current gps time 102941.000 current gps latitude 51.500000 current gps n\s i...

  • Page 192: Topics

    Radwin 5000 hpmp point to multipoint broadband wireless user manual release 3.2.00 part 5: advanced installation topics um 5000-3200/08.11.

  • Page 193: Chapter 11

    Radwin 5000 hpmp user manual release 3.2.00 11-1 chapter 11 software upgrade what is the software upgrade utility? The radwin manager provides a software upgrade utility (swu) to upgrade the software (firmware) of installed odus in a network. The update files may be located anywhere acces- sible by ...

  • Page 194

    Upgrading an installed sector chapter 11 radwin 5000 hpmp user manual release 3.2.00 11-2 upgrading an installed sector to upgrade software for a link: 1. In the radwin manager, click the software upgrade button.The following detached window appears: figure 11-1: software upgrade utility - main wind...

  • Page 195

    Upgrading an installed sector chapter 11 radwin 5000 hpmp user manual release 3.2.00 11-3 figure 11-3: adding a single site for upgrade enter the ip address of the site, the community strings (default: public and net- man, respectively) and then click ok. The site will appear in the software upgrade...

  • Page 196

    Upgrading an installed sector chapter 11 radwin 5000 hpmp user manual release 3.2.00 11-4 6. In addition to the previous step, you may opt to perform a delayed upgrade. Check the delayed upgrade box, and enter the date and time for the delayed upgrade. 7. The radio buttons on the right determines ho...

  • Page 197

    Upgrading an installed sector chapter 11 radwin 5000 hpmp user manual release 3.2.00 11-5 caution if one or both sites fail to update, a warning notice will be displayed. If one site of a link update fails, you should correct the problem and update the failed site as soon as possible. If you do not,...

  • Page 198: Chapter 12

    Radwin 5000 hpmp user manual release 3.2.00 12-1 chapter 12 vlan functionality with radwin 5000 hpmp vlan tagging - overview vlan terminology both the technical literature and the radwin manager use the terms vlan id and vid inter- changeably to denote a vlan identification number. Vlan background i...

  • Page 199

    Qinq (double tagging) for service providers chapter 12 radwin 5000 hpmp user manual release 3.2.00 12-2 figure 12-1: vlan scenarios handle by radwin 5000 hbs ieee 802.1q is used as the encapsulation protocol to implement this mechanism over ether- net networks. Qinq (double tagging) for service prov...

  • Page 200

    Vlan untagging chapter 12 radwin 5000 hpmp user manual release 3.2.00 12-3 the outer tag (representing the provider vlan) comes first, followed by the inner tag. In qinq the ethertype = 0x9100. Vlan tags may be stacked three or more deep. When using this type of “provider tagging” you should keep th...

  • Page 201

    Port functionality chapter 12 radwin 5000 hpmp user manual release 3.2.00 12-4 ingress direction table 12-1: port settings - ingress direction transparent the port ‘does nothing’ with regard to vlans - inbound frames are left untouched. Tag frames entering the hsu port without vlan or qinq tagging a...

  • Page 202

    Vlan configuration using the radwin manager chapter 12 radwin 5000 hpmp user manual release 3.2.00 12-5 egress direction vlan configuration using the radwin manager management traffic and ethernet service separation managing the hbs over the air from an hsu if traffic vlan tagging is in force for th...

  • Page 203

    Configuration of vlan tagging for ethernet service chapter 12 radwin 5000 hpmp user manual release 3.2.00 12-6 configuration of vlan tagging for ethernet service vlan configuration is carried out per hsu. It is up to you to ensure consistency between the hsus. Hsu vlan tagging can only be configured...

  • Page 204

    Configuration of vlan tagging for ethernet service chapter 12 radwin 5000 hpmp user manual release 3.2.00 12-7 in provider mode,ethernet frames are tagged with the provider’s vlan id before they enter into the provider’s network/backbone. 3. Enter a provider vlan id and priority. The vlan id must be...

  • Page 205

    Configuration of vlan tagging for ethernet service chapter 12 radwin 5000 hpmp user manual release 3.2.00 12-8 7. Click ok. Table 12-3: vlan configuration options - tag mode ingress egress transparent untag all filter transparent nothing further required nothing further required allow up to 4 vids t...

  • Page 206: Chapter 13

    Radwin 5000 hpmp user manual release 3.2.00 13-1 chapter 13 false radar mitigation facilities who needs it if you are using dfs frequency bands 5.3/5.4 ghz fcc and 5.4/5.8ghz etsi you should use this facility. Dfs and false radar mitigation about dfs under dfs frequency bands, it must be ensured tha...

  • Page 207

    Configuring false radar mitigation chapter 13 radwin 5000 hpmp user manual release 3.2.00 13-2 • staggered: false radars with variable repetition frequency within a burst period (applies to 5.4 ghz etsi only) configuring false radar mitigation the configuration method for the hbs (etsi and fcc/ic) i...

  • Page 208: Fcc/ic Considerations

    Fcc/ic considerations chapter 13 radwin 5000 hpmp user manual release 3.2.00 13-3 best option(s) to reduce or eliminate false radar detection without completely block- ing out real radar detection. 4. Check the mitigation features to be used. 5. When you are satisfied with your configuration paramet...

  • Page 209: Chapter 14

    Radwin 5000 hpmp user manual release 3.2.00 14-1 chapter 14 fcc/ic dfs considerations fcc 5.4ghz device registration the fcc requires that devices installed within 35 km of any tdwr location should be regis- tered in the voluntary wispa sponsored database. The fcc has published a tdwr location infor...

  • Page 210

    Registering the device chapter 14 radwin 5000 hpmp user manual release 3.2.00 14-2 2. Click the user registration button to enter the registration page..

  • Page 211

    Registering the device chapter 14 radwin 5000 hpmp user manual release 3.2.00 14-3 3. Fill in the registration page and click register. 4. To complete device registration enter the register device tab as shown:.

  • Page 212

    Registering the device chapter 14 radwin 5000 hpmp user manual release 3.2.00 14-4 you are offered this: 5. Fill in the required information in the preceding web page and click the register device button..

  • Page 213: Tdwr Table

    Tdwr table chapter 14 radwin 5000 hpmp user manual release 3.2.00 14-5 tdwr table the following table contains the latitude and longitude locations of terminal doppler weather radars (tdwr). Use this table to determine if the master or client device installed is within 35 km radius of a tdwr locatio...

  • Page 214

    Tdwr table chapter 14 radwin 5000 hpmp user manual release 3.2.00 14-6 ny floyd bennett field w 073 52 49 n 40 35 20 5647 mhz 8 97 oh dayton w 084 07 23 n 40 01 19 5640 mhz 922 97 oh cleveland w 082 00 28 n 41 17 23 5645 mhz 817 113 oh columbus w 082 42 55 n 40 00 20 5605 mhz 1037 113 ok aero. Ctr t...

  • Page 215: Chapter 15

    Radwin 5000 hpmp user manual release 3.2.00 15-1 chapter 15 quality of service prerequisites to use the facility you must be familiar with the use of vlan (802.1p) or diffserv. Qos - overview qos is a technique for prioritization of network traffic packets during congestion. Radwin 5000 hpmp sectors...

  • Page 216

    Setting up the hbs for qos chapter 15 radwin 5000 hpmp user manual release 3.2.00 15-2 setting up the hbs for qos from the hbs manager, enter configuration, open the ethernet tab and then qos configura- tion. Qos is disabled by default. You may chose between the vlan (802.1p) and diffserv methods. T...

  • Page 217

    Setting up an hsu for qos chapter 15 radwin 5000 hpmp user manual release 3.2.00 15-3 if you un-check a queue, it will be disabled for the sector. It will not prevent the hsu from configuring it as “live”. The purpose behind this is to avoid the necessity of reconfiguring qos for each hsu, should th...

  • Page 218

    Setting up an hsu for qos chapter 15 radwin 5000 hpmp user manual release 3.2.00 15-4 3. Ensure that the mode field is enabled. If you already configured the hbs (sector) for diffserv or vlan, then it will be enabled by default. If you need to change the mode, then you probably did not set the secto...

  • Page 219: Part 6: Field Installation

    Radwin 5000 hpmp point to multipoint broadband wireless user manual release 3.2.00 part 6: field installation topics um 5000-3200/08.11.

  • Page 220: Chapter 16

    Radwin 5000 hpmp user manual release 3.2.00 16-1 chapter 16 pole and wall installation odu mounting kit contents table 16-1: bill of materials: odu mounting kit item qty large clamp (see figure 16-1 ) 1 small clamp (see figure 16-2 ) 1 arm (see figure 16-3 ) 1 screw hex head m8x40 4 screw hex head m...

  • Page 221: Mounting An Odu On A Pole

    Mounting an odu on a pole chapter 16 radwin 5000 hpmp user manual release 3.2.00 16-2 mounting an odu on a pole figure 16-4: mounting on a pole.

  • Page 222: Mounting An Odu On A Wall

    Mounting an odu on a wall chapter 16 radwin 5000 hpmp user manual release 3.2.00 16-3 mounting an odu on a wall figure 16-5: mounting on a wall.

  • Page 223: Mounting An External Antenna

    Mounting an external antenna chapter 16 radwin 5000 hpmp user manual release 3.2.00 16-4 mounting an external antenna optional external antennas can be mounted on a pole. The external mounting kit varies according to the specific antenna model. Mounting a connectorized odu horizontally what follows ...

  • Page 224: Chapter 17

    Radwin 5000 hpmp user manual release 3.2.00 17-1 chapter 17 lightning protection and grounding guidelines meticulous implementation of the guidelines in this chapter will provide best protection against electric shock and lightning. The radwin lightning protection system consists of the following co...

  • Page 225

    Grounding for indoor/outdoor units chapter 17 radwin 5000 hpmp user manual release 3.2.00 17-2 figure 17-1: grounding antenna cables grounding for indoor/outdoor units odu grounding radwin lightning protection system uses a shielded cat 5e cable to interconnect the out- door (odu) and indoor (idu) u...

  • Page 226

    Idu grounding chapter 17 radwin 5000 hpmp user manual release 3.2.00 17-3 idu grounding the idu grounding post should be connected to the internal ground point, using a grounding wire of at least 10 awg. The grounding wire should be connected to a grounding rod or the building grounding system. The ...

  • Page 227

    Using lightning protectors and grounding chapter 17 radwin 5000 hpmp user manual release 3.2.00 17-4 figure 17-3: grounding a typical pole installation.

  • Page 228

    Using lightning protectors and grounding chapter 17 radwin 5000 hpmp user manual release 3.2.00 17-5 figure 17-4: grounding a typical wall installation the next figure shows a close-up of the rear of grounded odu:.

  • Page 229

    Mounting radwin lighting protection unit chapter 17 radwin 5000 hpmp user manual release 3.2.00 17-6 figure 17-5: odu lightning protector and grounding mounting radwin lighting protection unit to mount a lightning protection device: 1. Mount the device as close to the odu as possible. 2. Mount the u...

  • Page 230

    Internal esd protection circuits chapter 17 radwin 5000 hpmp user manual release 3.2.00 17-7 to mount the lightning protection at the building entry point: 1. Mount the device outside the building, located as near as possible to the entrance of the cat 5e odu-idu cable. 2. Mount the unit to on the p...

  • Page 231: Chapter 18

    Radwin 5000 hpmp user manual release 3.2.00 18-1 chapter 18 link budget calculator overview the link budget calculator is a utility for calculating the expected performance of the rad- win 5000 hpmp wireless link within a sector and the possible configurations for a specific link range. The utility ...

  • Page 232: Calculations

    Calculations chapter 18 radwin 5000 hpmp user manual release 3.2.00 18-2 calculations eirp expected rss and fade margin where: site a is the transmitting site site b is the receiving site pathloss is calculated according to the free space model, where sensitivity is dependent on air-rate. Min and ma...

  • Page 233: About The Fresnel Zone

    Antenna height chapter 18 radwin 5000 hpmp user manual release 3.2.00 18-3 antenna height the recommended antenna height required for line of sight is calculated as the sum the fres- nel zone height and the boresight height. See about the fresnel zone below. Using the notation of figure 18-1 below, ...

  • Page 234

    About the fresnel zone chapter 18 radwin 5000 hpmp user manual release 3.2.00 18-4 figure 18-1: fresnel zone fresnel loss is the path loss occurring from multi-path reflections from reflective surfaces such as water, and intervening obstacles such as buildings or mountain peaks within the fresnel zo...

  • Page 235

    Running the link budget calculator chapter 18 radwin 5000 hpmp user manual release 3.2.00 18-5 running the link budget calculator the link budget calculator is supplied on the radwin manager cd. It may be run stand- alone from the cd or from the radwin manager application. To run the link budget cal...

  • Page 236

    Running the link budget calculator chapter 18 radwin 5000 hpmp user manual release 3.2.00 18-6 to use the link budget calculator for radwin 5000 hpmp: 1. Click the radwin 5000 hpmp tab. Figure 18-4: radwin 5000 hpmp lbc main window 2. Chose the required radwin 5000 hpmp band. Note • microsoft intern...

  • Page 237

    Running the link budget calculator chapter 18 radwin 5000 hpmp user manual release 3.2.00 18-7 figure 18-5: band selector for the purposes of our example, we will use 5.730-5.845 ghz fcc/ic connector- ized. 3. Enter the radio details. The fade margin is the minimum required for line-of-sight (los) c...

  • Page 238

    Running the link budget calculator chapter 18 radwin 5000 hpmp user manual release 3.2.00 18-8 figure 18-6: calculation of distance from site coordinates if for example, we enter: site a: 41.1°n lat 74.2°w long site b: 40.8°n lat 74.0°w long and press set, the range will be calculated and displayed:.

  • Page 239

    Running the link budget calculator chapter 18 radwin 5000 hpmp user manual release 3.2.00 18-9 6. Located to the right of the green coordinates button is a drop-down list of climactic c factor values. It is only available if you choose a non-adaptive rate. Figure 18-7: climactic c factors for help a...

  • Page 240

    Running the link budget calculator chapter 18 radwin 5000 hpmp user manual release 3.2.00 18-10 figure 18-8: climactic c factor description in figure 18-9 we display a map of the world showing c factor contours: figure 18-9: world map showing c factor contours.

  • Page 241

    Running the link budget calculator chapter 18 radwin 5000 hpmp user manual release 3.2.00 18-11 7. Click calculate to obtain the required performance estimate. Figure 18-10: lbc - results section the expected performance parameters are calculated and displayed: • expected rss - the expected rss that...

  • Page 242: Chapter 19

    Radwin 5000 hpmp user manual release 3.2.00 19-1 chapter 19 spectrum view what is spectrum view? The radwin manager spectrum view utility is an rf survey tool designed to support the sec- tor installation prior to full sector service activation. The tool provides comprehensive and clear spectral mea...

  • Page 243

    Where is the spectrum view data stored chapter 19 radwin 5000 hpmp user manual release 3.2.00 19-2 range and operating band from the hbs. In the former case, expect a “noise hump” around the channels used by the sector, due to the duty signals from the hbs. Where is the spectrum view data stored spe...

  • Page 244

    Spectrum view main window: hbs chapter 19 radwin 5000 hpmp user manual release 3.2.00 19-3 the settings are “sticky” for the hbs and will be reused. The analysis range is limited from 4900 to 6050 mhz with a maximum difference of 500mhz. Erroneous entries will be shown with a red border like this: t...

  • Page 245

    Spectrum view main window: hbs chapter 19 radwin 5000 hpmp user manual release 3.2.00 19-4 if for example you click show on the hbs, the following view will open in the right panel: figure 19-1: spectrum view data panel for the hbs, ready for data the standard x button closes the window completely (...

  • Page 246

    Spectrum view display function buttons chapter 19 radwin 5000 hpmp user manual release 3.2.00 19-5 the two side arrows (circled) are used to reorder a stack of such view on the display area: the remaining controls on the spectrum view main window relate to spectrum view data manipulation. We will co...

  • Page 247

    Running spectrum view from the hbs chapter 19 radwin 5000 hpmp user manual release 3.2.00 19-6 running spectrum view from the hbs choose entire sector and click start. You are offered the following cautionary message: if it is acceptable to drop the service click yes. The processing may appear to ha...

  • Page 248

    Running spectrum view from the hbs chapter 19 radwin 5000 hpmp user manual release 3.2.00 19-7 the keys to the color coding is permanently displayed at the bottom of the main window: figure 19-2: spectrum view analysis color codes the green band reflects the current hbs operating frequency. Notice a...

  • Page 249

    Running spectrum view from an hsu chapter 19 radwin 5000 hpmp user manual release 3.2.00 19-8 the light green rectangle in the background of both antenna displays reflects actual channel (20 mhz wide here) being used by the hsu. The title bar also contains the hsus ip address. There is a further dis...

  • Page 250

    Running spectrum view from an hsu chapter 19 radwin 5000 hpmp user manual release 3.2.00 19-9 figure 19-3: hsu spectrum analysis in complete isolation from the sector now we return the hsu to the sector: figure 19-4: hsu spectrum analysis within the sector the hump in figure 19-4 reflects the duty c...

  • Page 251: Chapter 20

    Radwin 5000 hpmp user manual release 3.2.00 20-1 chapter 20 using the web interface what is it for the web interface (wi) enables you to carry out basic sector management functions using a web browser. It may be used to - • monitor a sector on a minimal basis • check sector parameters and make limit...

  • Page 252: How It Works

    How it works chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-2 how it works assume the sector setup, which we used in chapter 4 and late. We repeat it here for conve- nience: on the managing computer, point your browser to192.168.10.200 and log on as shown below. You can also log on over t...

  • Page 253: Prerequisites

    Prerequisites chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-3 prerequisites hardware you need a regular lan connection between a managing computer and one of the sector odus. The wi can be used directly opposite the hbs any of its hsus. It can also be used over the air from the hbs to an...

  • Page 254: Scope of This Chapter

    Scope of this chapter chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-4 be very careful: » using this tool if your link is providing customer service which may not be interrupted with sync-losses scope of this chapter the remainder of this chapter is divided into three sections: logging on...

  • Page 255: Hbs Management

    Hbs management chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-5 hbs management the main window figure 20-2: web interface - main window, hbs the sector id (ebg_20561334) appears all or in part as the heading. The hbs info panel is self explanatory. The green active indicator will vary acc...

  • Page 256

    Configure chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-6 figure 20-4: hsu haydn deregistered now, click anywhere on the hbs info panel: configure the configure button opens the following display:.

  • Page 257

    Configure chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-7 system the name, contact and location field may be changed. Clicking save commits them. Clicking refresh reverts the fields to their last saved values. Air interface there is nothing that can be changed on this panel. Clicking the...

  • Page 258

    Configure chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-8 management the management fields are all fully editable: caution changing antenna type will call a sector-wide sync loss..

  • Page 259

    Configure chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-9 if you change any of these fields, you will cause an hbs reset:.

  • Page 260

    Configure chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-10 other you may change the hbs lan port configuration: you will receive the following notification:.

  • Page 261: Hsu Management

    Events chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-11 this action of course, has no bearing on the sector. Events the recent event list is displayed: reset use this button to reset the hbs. Hsu management hsu management follows the same pattern as that for the hbs. To avoid tedious rep...

  • Page 262

    The main window chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-12 click mozart. Here is what you see: clicking configure, opens up a new tab in you browser, pointing to mozart:.

  • Page 263

    The main window chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-13 here is the hsu main window: the only item here requiring comment is the configure button. Install is disabled and the remaining three buttons are the same as for the hbs. Here is the configure display: the only fucction he...

  • Page 264

    The main window chapter 20 radwin 5000 hpmp user manual release 3.2.00 20-14 in addition to the antenna & tx power button, you may also change operating band: . Warning there are two strict caveats to using this function: • it is intended as a tool for the field technician, replacing an hsu in the f...

  • Page 265: Part 7: Product Reference

    Product reference radwin 5000 hpmp point to multipoint broadband wireless user manual release 3.2.00 part 7: product reference um 5000-3200/08.11.

  • Page 266: Appendix A

    Radwin 5000 hpmp user manual release 3.2.00 a-1 appendix a technical specifications scope of these specifications this appendix contains technical specifications for the major link components appearing in this user manual. They are correct at the date of publication, but are intended for general bac...

  • Page 267

    Odu - hbs and hsu appendix a radwin 5000 hpmp user manual release 3.2.00 a-2 band (ghz) regulation occupied frequency range (ghz) supported channel bandwidth (mhz) compliance 2.5 fcc brs(*) 2.495- 2.690 5, 10, 20 fcc 47cfr, part 27, subpart m (brs/ebs) 3.5 etsi(†) 3.4105 – 3.7025 5, 10, 20 etsi en 3...

  • Page 268

    Gbe poe device - indoor, ac for hbs only appendix a radwin 5000 hpmp user manual release 3.2.00 a-3 gbe poe device - indoor, ac for hbs only management application (per sector) radwin manager protocol snmp and telnet nms radwin nms - rnms operating temperatures hbs/hsu: -35°c to +60°c / -31°f to +14...

  • Page 269: Poe Device - Indoor, Ac

    Poe device - indoor, ac appendix a radwin 5000 hpmp user manual release 3.2.00 a-4 poe device - indoor, ac operating temperatures 0°c - 40°c humidity 90% non-condensing ul 60950 c-ul 60950 tuv/gs iec/en 60950 esd 61000-4-2 rs 61000-4-3 eft 61000-4-4 surge 61000-4-5 cs 61000-4-6 dips 61000-4-11 emi f...

  • Page 270: Poe Device - Outdoor, Dc

    Poe device - outdoor, dc appendix a radwin 5000 hpmp user manual release 3.2.00 a-5 poe device - outdoor, dc ul 60950 c-ul 60950 tuv/gs iec/en 60950 esd 61000-4-2 rs 61000-4-3 eft 61000-4-4 surge 61000-4-5 cs 61000-4-6 dips 61000-4-11 emi fcc part 15 class b, cispr pub 22 class b input voltage range...

  • Page 271: Gsu

    Gsu appendix a radwin 5000 hpmp user manual release 3.2.00 a-6 gsu antenna characteristics an antenna is the radiating and receiving element from which the radio signal, in the form of rf power, is radiated to its surroundings and vice versa. The transmission range is a function of the antenna gain ...

  • Page 272: Appendix B

    Radwin 5000 hpmp user manual release 3.2.00 b-1 appendix b wiring specifications odu-poe cable (hbs and hsu) the odu-poe cable is shielded/outdoor class cat-5e, 4 twisted-pair 24 awg terminated with rj-45 connectors on both ends. A cable gland on the odu side provides hermetic sealing. The following...

  • Page 273: User Port Connectors

    User port connectors appendix b radwin 5000 hpmp user manual release 3.2.00 b-2 user port connectors lan port the lan 10/100baset interface terminates in an 8-pin rj-45 connector, wired in accordance to table b-3 . Dc power terminals dc poe white/brown 7 7 brown 8 8 table b-3: fast ethernet connecto...

  • Page 274: Appendix C

    Radwin 5000 hpmp user manual release 3.2.00 c-1 appendix c mib reference introduction about the mib the radwin mib is a set of apis that enables external applications to control radwin equipment. The mib is divided into public and a private api groups: • public: rfc-1213 (mib ii) variables, rfc-1214...

  • Page 275: Private Mib Structure

    Community string appendix c radwin 5000 hpmp user manual release 3.2.00 c-2 tains data on each of the idus and odus in the link. Both agents communicate with each other over the air using a proprietary protocol. To control and configure the device using the mib, you should adhere to the following ru...

  • Page 276: Mib Parameters

    Mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-3 figure c-2: product mib the gpssynchronizerfamily mib defines the gsu. The general mib include a single generic parameter that is used by all traps as a trap descrip- tion parameter. Mib parameters the following section descri...

  • Page 277

    Supported variables from the rfc 1213 mib appendix c radwin 5000 hpmp user manual release 3.2.00 c-4 ifspeed .1.3.6.1.2.1.2.2.1.5 gauge ro an estimate of the interface's current bandwidth in bits per second.For interfaces which do not vary in bandwidth or for those where no accurate estimation can b...

  • Page 278

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-5 private mib parameters table c-2: private mib parameters (sheet 1 of 25) name oid type ac ces s description winlink1000oduadmproducttype 1.3.6.1.4.1.4458.1000.1.1.1 displaystring ro odu configuration description. Winli...

  • Page 279

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-6 winlink1000odutrapcommunity 1.3.6.1.4.1.4458.1000.1.1.17 displaystring rw trap community string. This parameter is used by the manager application to change the trap community string. The snmp agent accepts only encryp...

  • Page 280

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-7 winlink1000odusrvringethstatus ro represents the ethernet service blocking state of a rings link winlink1000odusrvringmaxallowedtimefrom lastrpm rw defines the minimal time (in ms) required for determination of ring fa...

  • Page 281

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-8 winlink1000odubridgebaseporttable n/a odu bridge ports table. Winlink1000odubridgebaseportentry n/a odu bridge ports table entry. Index { winlink1000odubridgebaseportindex } winlink1000odubridgebaseportindex ro odu bri...

  • Page 282

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-9 winlink1000oduairtxpower48 1.3.6.1.4.1.4458.1000.1.5.11 integer rw deprecated parameter. Actual behavior is read- only. Winlink1000oduaircurrenttxpower 1.3.6.1.4.1.4458.1000.1.5.12 integer ro current transmit power in ...

  • Page 283

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-10 winlink1000oduairchannelbwavail 1.3.6.1.4.1.4458.1000.1.5.25.1.2 integer ro channel bandwidth availability product specific. Options are: not supported supported with manual channel selection supported with automatic ...

  • Page 284

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-11 winlink1000oduairhssrfpethchannelbw5mh z 1.3.6.1.4.1.4458.1000.1.5.40.7.1.2 integer ro represents the compatibility of ethernet service under channel bw of 5mhz in the specific radio frame pattern. Winlink1000oduairhs...

  • Page 285

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-12 winlink1000oduairantennagainconfigsupport 1.3.6.1.4.1.4458.1000.1.5.47 integer ro antenna gain configurability options are product specific: supported not supported. Winlink1000oduairantennatype 1.3.6.1.4.1.4458.1000....

  • Page 286

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-13 winlink1000oduairspectrumchannellastnfan tennaa 1.3.6.1.4.1.4458.1000.1.5.56.5.1.5 integer ro normalized noise floor value in dbm - of antenna a - (including 2 neighbor frequencies). Winlink1000oduairspectrumchannella...

  • Page 287

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-14 winlink1000oduairminusablemastertxratio 1.3.6.1.4.1.4458.1000.1.5.60.3 integer ro represents the minimal value the user can configure for desired net master tx ratio. Winlink1000oduairmaxusablemastertxratio 1.3.6.1.4....

  • Page 288

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-15 winlink1000oduperfmonintervaltable n/a this table defines/keeps the counters of the last day (in resolution of 15 min intervals). Winlink1000oduperfmonintervalentry n/a this is an entry in the interval table. Index {i...

  • Page 289

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-16 winlink1000oduperfmondaycompressed ro holds a compressed string of all data per interface. Compressed air interface structure (size in brackets): uas (4) es (4) ses (4) bbe (4) integrity (1) minrsl (1) maxrsl (1) rslt...

  • Page 290

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-17 winlink1000oduperfmonairintervaltslthresh 1exceed ro number of seconds transmit signal level exceeded the tsl1 threshold per interval. Winlink1000oduperfmonairintervalbberthres h1exceed ro number of seconds background...

  • Page 291

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-18 winlink1000oduperfmonethdaytable n/a this table defines/keeps the ethernet counters of the last month (in resolution of days). Winlink1000oduperfmonethdayentry n/a this is an entry in the days table. Index {ifindex wi...

  • Page 292

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-19 winlink1000oduperfmonethcapacitythreshkb ps 1.3.6.1.4.1.4458.1000.1.6.24 integer rw when the current throughput is below this threshold the corresponding counter is incremented winlink1000oduperfmonhightrafficthreshkb...

  • Page 293

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-20 winlink1000oduagnlasteventstable n/a this table includes the last events. When a trap is sent an event entry is added to the table. Winlink1000oduagnlasteventsentry n/a entry containing the details of last traps. Inde...

  • Page 294

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-21 winlink1000iduadmportsconnection rw idu ports connection bitmap. Bit 0 - lan1-lan2 bit 1 - sfp-lan1 bit 2 - sfp-lan2 bit values: 0 - ports are disconnected. 1 - ports are connected. Winlink1000iduadmvlanmode rw local ...

  • Page 295

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-22 winlink1000idusrvavailservicesstate ro represents the tdm service availability. Winlink1000idusrvavailservicesminrateidx ro minimum rate index of the air interface which make the service possible. Winlink1000idusrvava...

  • Page 296

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-23 winlink1000idutdmmasterclockavailoptions ro available options of the tdm master clock control each input status is represented by a bit. When the option is available the bit value is 1. When the option is unavailable ...

  • Page 297

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-24 winlink1000idutdmbackupcurrentactivelink ro tdm backup current active link: n/a air link is active or external link is active. Winlink1000idutdmjitterbuffersize rw tdm jitter buffer size. The value must be between the...

  • Page 298

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-25 winlink1000hbsairconfnumofts 1.3.6.1.4.1.4458.1000.3.1.6.2.1.7 integer rw number of time slot which are allocated to specific hsu. Winlink1000hbsairlinknumoflinks 1.3.6.1.4.1.4458.1000.3.1.7.1 integer ro number of lin...

  • Page 299

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-26 winlink1000hbsaircpecapacitylimit 1.3.6.1.4.1.4458.1000.3.1.7.2.1.24 integer ro capacity limit in kilo bit per second. Winlink1000hbsairlinkantennatype 1.3.6.1.4.1.4458.1000.3.1.7.2.1.25 integer ro hsu external antenn...

  • Page 300

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-27 winlink1000oduservicevlantblegressfilter4 1.3.6.1.4.1.4458.1000.3.3.2.1.1.10 integer rw vlan filter4 vid winlink1000hbsserviceqosmode 1.3.6.1.4.1.4458.1000.3.3.3.1 integer rw quality of service mode. Winlink1000hbsser...

  • Page 301

    Private mib parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-28 winlink1000hbsperfmonairgencurractiveseco nds 1.3.6.1.4.1.4458.1000.3.4.2.1.5 gauge ro the number of seconds in which rpl ethernet swervice was not blocked in the present 15 minutes period. Winlink1000hbsperfmonairgen...

  • Page 302

    Mib traps appendix c radwin 5000 hpmp user manual release 3.2.00 c-29 mib traps general each odu can be configured with up to 10 different trap destinations. When the link is oper- ational, each odu sends traps originating from both site a and site b. The source ip address of the trap is the sending...

  • Page 303

    Trap parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-30 trap parameters table c-3: mib traps (sheet 1 of 5) name id severity description trunkstatechanged 1 normal indicates a change in the state of one of the tdm trunks. Raised by both sides of the link. Contains 3 parameters: 1...

  • Page 304

    Trap parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-31 hssopstatechangedtoinu 19 normal indicates that the hss operating state was changed to inu type. Contains a single parameter which is its description: 1 - description: hss operating state was changed to: inu. Hssopstatechang...

  • Page 305

    Trap parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-32 lanport2disconnectedalarm 110 major indicates the lan port 2 status changed to disconnected.Contains a single parameter which is its description: 1 - description: lan port 2 status changed to disconnected. Mngportdisconnecte...

  • Page 306

    Trap parameters appendix c radwin 5000 hpmp user manual release 3.2.00 c-33 pdtoohighduecbwlimitations 132 major indicates that link cannot be established because link range is too large for channel bandwidth. Hbsencryptionalarm 133 major indicates an encryption key mismatch. Contains a single param...

  • Page 307: Radwin Manager Traps

    Radwin manager traps appendix c radwin 5000 hpmp user manual release 3.2.00 c-34 radwin manager traps the radwin manager application issues traps to indicate various events. These traps are shown in the radwin managerr events log. A list of trap messages as displayed by the radwin manager is shown i...

  • Page 308: Appendix D

    Radwin 5000 hpmp user manual release 3.2.00 d-1 appendix d rf exposure the antennas used for the following transmitters must be installed so as to provide a mini- mum separation distance from bystanders as specified in the following tables: table d-1: safety distances for radwin 5000 hpmp fcc and ic...

  • Page 309

    Rf exposure appendix d radwin 5000 hpmp user manual release 3.2.00 d-2.

  • Page 310: Appendix E

    Radwin 5000 hpmp user manual release 3.2.00 e-1 appendix e setting antenna parameters antenna issues the choice of tx power, antenna gain and cable loss (between the radio and the antenna) determines the eirp and is affected by such considerations as radio limitations and regulatory restrictions. Be...

  • Page 311

    Single antennas at both sites appendix e radwin 5000 hpmp user manual release 3.2.00 e-2 upon selecting antenna type as dual, radwin 5000 hpmp automatically selects mimo mode and doubles the air rates. Radwin manager indicates a case of unbalanced rss between the two antennas in the hbs panels. Dive...

  • Page 312

    Considerations for changing antenna parameters appendix e radwin 5000 hpmp user manual release 3.2.00 e-3 table e-1 summarizes the situation: site a and b may be hbs or hsu. The rates used by radwin 5000 hpmp are shown in table e-2 below: considerations for changing antenna parameters let: max avail...

  • Page 313

    Considerations for changing antenna parameters appendix e radwin 5000 hpmp user manual release 3.2.00 e-4 maxregeirp denote the maximum eirp available by regulation. It will be determined by three factors: • per band/regulation • per channel bandwidth • antenna gain maxregtxpower denote the maximum ...

  • Page 314: Appendix F

    Radwin 5000 hpmp user manual release 3.2.00 f-1 appendix f regional notice: french canadian procédures de sécurité généralités avant de manipuler du matériel connecté à des lignes électriques ou de télécommunications, il est conseillé de se défaire de bijoux ou de tout autre objet métallique qui pou...

  • Page 315

    Précautions de sécurité pendant le montage de odu appendix f radwin 5000 hpmp user manual release 3.2.00 f-2 win conseille l'utilisation d'un dispositif de parafoudre supplémentaire afin de protéger le matériel de coups de foudre proches. Matériel supplémentaire requis l'équipement requis pour l'ins...

  • Page 316

    Contenu du kit de montage odu appendix f radwin 5000 hpmp user manual release 3.2.00 f-3 contenu du kit de montage odu le kit de montage odu comprend les pièces suivantes: • une grande clame (voir figure f-1 ) • une petite clame (voir figure f-2 ) • un bras (voir figure f-3 ) • quatre visses hex têt...

  • Page 317

    Montage sur un pylône appendix f radwin 5000 hpmp user manual release 3.2.00 f-4 figure f-4: montage sur un pylône.

  • Page 318

    Montage sur un mur appendix f radwin 5000 hpmp user manual release 3.2.00 f-5 montage sur un mur figure f-5: montage sur un mur.

  • Page 319

    Montage d'une antenne externe appendix f radwin 5000 hpmp user manual release 3.2.00 f-6 montage d'une antenne externe l'antenne externe optionnelle peut être montée sur un pylône. Contenu du kit de montage d'une antenne externe le kit de montage d'une antenne externe comprend les pièces suivantes •...

  • Page 320: Index

    Radwin 5000 hpmp user manual release 3.2.00 index 1 a aging time, hbs bridge mode 6-16 air interface technical specifications, general a-1 antenna mode mimo and diversity, hsu 5-30 antennas air rates e-3 aligning buzzer signals from hsu 3-12 cable, grounding 17-1 diversity mode e-2 external 3-4 , 3-...

  • Page 321

    Radwin 5000 hpmp user manual release3.2.00 index 2 hss client 9-2 continue transmission 9-3 disable transmission 9-3 hss master 9-2 hsu aligning to hbs 3-11 button bar menu 4-14 configuration configuration with telnet 6-39 defined 1-2 deregistration 5-31 events log 4-18 hbs panel 4-12 link performan...

  • Page 322

    Radwin 5000 hpmp user manual release3.2.00 index 3 r radio frame pattern (rfp) general considerations 9-8 general considerations 9-8 with hss 9-7 without hss 9-7 radio link additional tools and materials required 3-7 air rates e-3 connecting user equipment 3-11 hardware installation external antenna...