  • Page 1

    T series water softener installation & operation manual (please save for future reference) thank you for purchasing one of our envirogard / rainfresh water softeners. We are committed to ensuring that you are totally satisfied. If you have any problems, don’t go back to the store – please contact us...

  • Page 2

    2 system specifications & dimensions model system capacity (grains) flow rate media tank size resin type resin volume (cu ft) unit weight lbs (kg) @ 15 lbs salt/ft³ service (us gpm) peak (us gpm) backwash (us gpm) 30t 30,000 5 9.0 2.0 9” x 48” cation softening resin 1.0 87 (39.5) 45t 45,000 7.5 12.0...

  • Page 3

    3 installation figure 1. Piping diagram electrical requirements: the automatic control valve requires a constant power supply - 110v ac. We recommend a gfci (ground fault circuit interrupter) outlet within 5 feet of the softener. Extension cords are not recommended. If water pipes are used to ground...

  • Page 4

    4 if you have a private well, turn the power off to the pump then shut off the main water shut off valve. If you have municipal water, simply shut off the main valve. Go to a faucet, (preferably on the lowest floor of the house) turn on the cold water until all pressure is relieved and the flow of w...

  • Page 5

    5 start up & programming the control valve is controlled with simple, user-friendly electronics displayed on an lcd screen. When power is first supplied, the valve electronics may take up to two minutes to initialize. During this time the screen will show “intializing wait please”. Do not touch any ...

  • Page 6

    6 step 2 : setting current date step 3: setting number of people step 4: setting water hardness this value is the maximum water hardness in grains per gallon (gpg) of the raw water supply. If you have the reading in ppm or mg/l, simply multiply by 17.1 to get the reading in gpg. You must also add (5...

  • Page 7

    7 salt setting (lbs/cu ft) model 6.0 8.0 10.0 12.0 15.0 30t 2.9 3.8 4.8 5.7 7.1 45t 4.2 5.7 7.1 8.5 10.7 60t 5.7 7.6 9.6 11.4 14.2 table 1 : refill time (in minutes) for various salt settings (or next whole number) step 7: manual regeneration if screen is locked, press “ menu” for 3 seconds to unloc...

  • Page 8

    8 other features control operation during a power failure in the event of a power failure, the valve will keep track of the time and day for 48 hours. The programmed settings are stored in a non-volatile memory and will not be lost during a power failure. If power fails while the unit is in regenera...

  • Page 9

    9 trouble shooting need help troubleshooting? Call toll free 1-800-667-8072 monday to friday 8:30 am to 5 pm est. Issue possible cause possible solution 1. No power supply. Check electrical service, fuse, etc. 2. Defective circuit board. Replace faulty parts. 3. Power failure. Reset time of day. 1. ...

  • Page 10

    10 to order replacement parts, call 1800 667 8072 monday to friday 8:30 am to 5 pm est. Limited warranty: this “t” series softener system is warranted to the original consumer purchaser for a period of one (1) year, from the date of purchase, against defects in materials or workmanship. The electron...