Rainfresh 30T Installation And Operation Manual - page 5
5
START UP & PROGRAMMING
The control valve is controlled with simple, user-friendly electronics displayed on an LCD screen. When power is first
supplied, the valve electronics may take up to two minutes to initialize. During this time the screen will show “INTIALIZING
WAIT PLEASE”. Do not touch any buttons at this time. When the valve reaches the service position, it will display the
following information in sequence:
1.
Date & Time
2.
Regeneration Days/Capacity
3.
Remaining Days/Volume Remaining
4.
Regeneration Time
5.
Last Regeneration Date
6.
Current Flow Rate (GPM)
7.
Peak Flow Rate (GPM)
The control valve has a display screen and 4 buttons
VALVE PROGRAMMING
The valve has 2 levels of programming – Level 1 and Level 2
You will need to only go through Level 1 programming to start up your unit. Level 2 programming is factory set and
can be changed only if desired.
Level 1 programming allows you to set
1. Current time
2. Current date
3. Number of people
4. Feed water hardness
Level 2 programming sets valve operational settings, if required.
LEVEL 1 USER PROGRAMMING
STEP 1 : Setting Current Time
Press “
MENU” for 3 seconds
to unlock screen. Press “
MENU” again and the hour
value becomes highlighted
Press “
SET/REGEN”
once again and the
highlighted value
flashes.
Now press “
or
UP
OR
DOWN”
arrows to change the
hour values.
Press “
SET/REGEN” again
to accept the hour value
and advance to change the
minute value.
Press “
or
UP OR
DOWN” arrows to change
the minute values.
Press “
SET/REGEN”
again to accept the
minute
values
and
advance to adjust the
AM/PM values.
Press “
or
UP
OR DOWN” to change
the AM/PM value.
Press “
SET / REGEN” again
to accept the AM/PM value.
Highlight stops flashing.
PROCEED TO STEP 2
MENU BUTTON
“ ”
The function of this key is to
enter the level one
programming mode where the
valve settings can be adjusted.
SET / REGEN BUTTON
“
”
This button has two functions. The first is to initiate a
manual regeneration by holding the button for 3 or
more seconds. The second function is while in
programming mode, pressing this key allows the user to
change the value of each setting.
UP / DOWN
“
”
These buttons are used to
increase or decrease the value
of the settings while in the
programming mode.