Summary of RINA

  • Page 1

    English rais ­ manual for rais rina & rais viva 1 instructions for installation, use and maintenance rais rina & rais viva important information on first lighting the stove you must be careful not to touch the painted surfaces and it is most important that the door is kept slightly ‘ajar’ in order f...

  • Page 2

    English rais ­ manual for rais rina & rais viva 2.

  • Page 3

    English rais ­ manual for rais rina & rais viva 3 revision : date : 2011 introduction ………………………………………………………….. 4 warranty …………………………………………………….………….. 4 specifications ………………………………………………………….. 5 convection ………………………………………………………………. 6 installation instructions ………………………………….……… 7 chimney …………………………………...

  • Page 4

    English rais ­ manual for rais rina & rais viva 4 a rais wood burning stove is more than just a heat source: it also shows that you care about design and quality in your home. To make the most of your wood burning stove it is important that you read the manual thoroughly before installing and using ...

  • Page 5

    English rais ­ manual for rais rina & rais viva 5 rin a 9 0 no m in al o u tp u t ( kw) : 4.6 heat in g a rea ( m 2 ): ca. 3 0­ 90 s ize, wi d th /d e p th /h ei g h t ( m m ): 46 1 / 4 1 0 / 9 00 co m b u st io n c h ambe r wi d th /d ep th /h eig h t (m m ). 29 5 / 2 2 5 / 3 93 reco m m en d ed a ...

  • Page 6

    English rais ­ manual for rais rina & rais viva 6 convection rais stoves are convection stoves. This means that the stove’s back and side panels are not over­heated. Convection means that there is a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room...

  • Page 7

    English rais ­ manual for rais rina & rais viva 7 please note that it is a legal requirement under england and wales building regulations that the installation of the stove is either carried out under local authority building control approval or is installed by a competent person registered with a g...

  • Page 8

    English rais ­ manual for rais rina & rais viva 8 stove performance in the uk the stove has been approved by hetas ltd as an intermittent operating appliance for burning wood logs only. It should be noted that it is an offence to burn wood logs in this stove if it is installed within a smoke control...

  • Page 9

    English rais ­ manual for rais rina & rais viva 9 a single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its dimension should be not less t...

  • Page 10

    English rais ­ manual for rais rina & rais viva 10 combustion air supply in order for the stove to perform efficiently and safely there should be an adequate air supply into the room in which the stove is installed to provide combustion air. This is particularly necessary if the room is double­glaze...

  • Page 11

    English rais ­ manual for rais rina & rais viva 11 installation it is prohibited to carry out unauthorised alterations to the stove. There must be plenty of fresh air in the room where the stove is being installed, in order to ensure proper combustion. Note that any mechanical exhaust ventilation ­ ...

  • Page 12

    English rais ­ manual for rais rina & rais viva 12.

  • Page 13

    English rais ­ manual for rais rina & rais viva 13.

  • Page 14

    English rais ­ manual for rais rina & rais viva 14 remove the casing knock­out. Remove the protective cover / seal and place over the hole in the top ­ make sure that the seal is positioned properly. Tighten the assembly using the three m6 nuts. The flue outlet spigot, which can be found in the stov...

  • Page 15

    English rais ­ manual for rais rina & rais viva 15 installation distance to combustible wall to find out whether the wall next to where the stove is going to be installed is flammable, you should contact your building contractor or the local building authorities. The hearth should be able to accommo...

  • Page 16

    English rais ­ manual for rais rina & rais viva 16 normal set­up ­ corner setting rina a. Distance to furniture 700 mm distance to flammable materials: b. ­ in front (floor) 300 mm c. ­ to the side (floor) 150 mm d. ­ to the rear (floor) 150 mm e. ­ to the side of the wall 350 mm.

  • Page 17

    English rais ­ manual for rais rina & rais viva 17 normal set­up ­ corner setting viva viva g a. Distance to furniture 700 mm 650 mm distance to flammable materials: b. ­ in front (floor) 300 mm 300 mm c. ­ to the side (floor) 150 mm 150 mm d. ­ to the rear (floor) 100 mm 150 mm e. ­ to the side of ...

  • Page 18

    English rais ­ manual for rais rina & rais viva 18 corner setting 45° fixed socket rina a. Distance to furniture 700 mm distance to flammable materials: b. ­ in front (floor) 300 mm c. ­ to the side (floor) 150 mm d. ­ to the rear (wall) 150 mm e. ­ to the side of the wall 350 mm.

  • Page 19

    English rais ­ manual for rais rina & rais viva 19 corner setting 45° fixed socket viva viva g distance to furniture 700 mm 650 mm distance to flammable materials: b. ­ in front (floor) 300 mm 300 mm c. ­ to the side (floor) 150 mm 150 mm d. ­ to the rear (wall) 100 mm 200 mm e. ­ to the side of the...

  • Page 20

    English rais ­ manual for rais rina & rais viva 20 360° swivel base viva viva g distance to furniture 700 mm 650 mm distance to flammable materials: c. ­ to the side (floor) 300 mm 300 mm.

  • Page 21

    English rais ­ manual for rais rina & rais viva 21 installation distance in case of non­combustible wall we recommend a minimum distance to non­combustible material of 50 mm (f) for clean­ing considerations. Using uninsulated flue pipe, the minimum distance to a combustible wall must be 450mm or 225...

  • Page 22

    English rais ­ manual for rais rina & rais viva 22 warning note properly installed, operated and maintained this stove will not emit fumes into the dwelling. Occasional fumes from de‑ashing and re‑fuelling may occur. However, persistent fume emission is potentially dangerous and must not be tolerate...

  • Page 23

    English rais ­ manual for rais rina & rais viva 23 if the stove is fitted in place of an open fire then the chimney will require sweeping after a month of continuous operation. This is a precaution to ensure that any “softer” deposits left from the open fire usage have not been loosened by the highe...

  • Page 24

    English rais ­ manual for rais rina & rais viva 24 chimney fires if the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does occur turn off the stove immediately and isolate the mains electricity supply (if applicable), and tightly close the door...

  • Page 25

    English rais ­ manual for rais rina & rais viva 25 refuelling keep the firebox well filled (the fuel may be sloped up from the front firebars), but do not allow fuel to spill over the top of the front fire bars. Take care that fuel does not project over the front fire bars or damage to the glass may...

  • Page 26

    English rais ­ manual for rais rina & rais viva 26 only use recommended fuels the following table shows the calorific value of different types of wood, which have been stored for 2 years and which have a residual moisture of 15 ­ 17%. Wood kg dry wood pr m 3 compared to beech/oak hornbeam 640 110% b...

  • Page 27

    English rais ­ manual for rais rina & rais viva 27 drying and storage drying wood takes time: proper air drying takes approximately 2 years. Here are some tips: store the wood sawn, split and stacked in an airy, sunny place, which is protected against rain (the south side of the house is particularl...

  • Page 28

    English rais ­ manual for rais rina & rais viva 28 control if the ash is white and the walls in the combustion chamber are soot free after the stove has been used, the air regulation was set correctly and the wood was sufficiently dry. Using the wood burning stove adjusting the air damper. The dampe...

  • Page 29

    English rais ­ manual for rais rina & rais viva 29 first usage a careful start pays off. Start with a small fire, so that the wood burning stove can get accustomed to the high temperature. This gives the best start and any damage is avoided. Be aware that a strange but harmless odour and smoke conco...

  • Page 30

    English rais ­ manual for rais rina & rais viva 30 lighting and fuelling "top­down" lighting start by placing 3­4 pieces wood ­ approx. 1 ½ ­ 2 kilogram ­ in the bottom of the burning chamber. Place approx. 1 kilogram of dry firewood, split into kindling sticks., and a couple of alcohol briquettes o...

  • Page 31

    English rais ­ manual for rais rina & rais viva 31.

  • Page 32

    English rais ­ manual for rais rina & rais viva 32 cleaning and care the wood burning stove and the chimney must be serviced by a chimney sweep twice a year. During cleaning and care, the stove must be cold. If the glass is sooty: ­ moisten a piece of paper or newspaper, dip it in the ash, and rub t...

  • Page 33

    English rais ­ manual for rais rina & rais viva 33 cleaning of flue way the flue ways are consist of a smoke converter plate and a smoke chicane. Both parts are made of vermiculite. Handle these parts carefully. Remove dirt and dust, and mount the parts in reverse order. Remove the smoke converter p...

  • Page 34

    English rais ­ manual for rais rina & rais viva 34 problem solving smoke spillage around door: ­ could be due to too low draught in the chimney ­ check if the flue or chimney is blocked ­ check if a extraction hood is switched on; if it is, switch it off and open a window/door in the proximity of th...

  • Page 35

    English rais ­ manual for rais rina & rais viva 35 accessories and spare parts if spare parts other than those recommended by rais are used, the warranty is voided. All replacement spare parts can be purchased from your rais distributor / stockist. See the following spare parts diagrams for the indi...

  • Page 36

    English rais ­ manual for rais rina & rais viva 36 spare parts diagram ­ rina pos./ref. Quantity part no: description 1 1 1312090 glass door 2 1 3310404 cover for wood compartment 3 1 3310601 top plate without hole 4 1 3310602 top plate with hole 5 1 61­00 flue collar 6” 6 1 1313800 shaking grate 7 ...

  • Page 37

    English rais ­ manual for rais rina & rais viva 37 rina.

  • Page 38

    English rais ­ manual for rais rina & rais viva 38 spare parts diagram ­ viva 98 pos./ref. Quantity part no: description 1 1 1312090 glass door 2 1 2310601 top plate without hole 3 1 2310602 top plate with hole 4 1 61­00 flue collar 6” 5 1 1313800 shaking grate 6 1 1314001 ash pan 7 1 1311790 air bo...

  • Page 39

    English rais ­ manual for rais rina & rais viva 39 viva 98.

  • Page 40

    English rais ­ manual for rais rina & rais viva 40 spare parts diagram ­ viva 120 pos./ref. Quantity part no: description 1 1 1312090 glass door 2 1 2310601 top plate without hole 3 1 2310602 top plate with hole 4 1 61­00 flue collar 6” 5 1 1313800 shaking grate 6 1 1314001 ash pan 7 1 1311790 air b...

  • Page 41

    English rais ­ manual for rais rina & rais viva 41 viva 120

  • Page 42

    English rais ­ manual for rais rina & rais viva 42 spare parts diagram ­ viva 98 g pos./ref. Quantity part no: description 1 1 1312090 glass door 5 1 2310601 top plate without hole 6 1 2310602 top plate with hole 7 1 61­00 flue collar 6” 8 1 1313800 shaking grate 9 1 1314001 ash pan 10 1 1311790 air...

  • Page 43

    English rais ­ manual for rais rina & rais viva 43 viva 98 g.

  • Page 44

    English rais ­ manual for rais rina & rais viva 44 spare parts diagram ­ viva 120 g pos./ref. Quantity part no: description 1 1 1312090 glass door 5 1 2310601 top plate without hole 6 1 2310602 top plate with hole 7 1 61­00 flue collar 6” 8 1 1313800 shaking grate 9 1 1314001 ash pan 10 1 1311790 ai...

  • Page 45

    English rais ­ manual for rais rina & rais viva 45 viva 120 g.

  • Page 46

    English rais ­ manual for rais rina & rais viva 46.

  • Page 47

    English rais ­ manual for rais rina & rais viva 47.

  • Page 48

    English rais ­ manual for rais rina & rais viva 48 u k distributor. Robeys ltd. Riverside, goods road, belper, derbyshire, england. De56 1uu tel: 01773 820940 fax: 01773 820477 e mail: info@robeys.Co.Uk www.Robeys.Co.Uk october 2011.