RAMSET T3MAG Instruction manual - Servicing / Troubleshooting
SYMPTOM
POSSIBLE PROBLEMS SERVICE
Power/Exhaust Stage of Operation
— Tool operates
— Battery cell is
— Charge Battery Cell
properly, but fasteners discharged
do not drive fully
— Fuel Cell is low
— Check Fuel Cell according to
Operating Manual and replace
as required.
— There may be loss of — Press Work Contact Element
seal in combustion
against workpiece for one minute.
chamber
Pull trigger. If fastener does not
drive, there is a leak that requires
service.
— Tool operates
— Fuel Cell is low
— Check Fuel Cell according to
erratically or appears
Operating Manual
to be losing power—
tool LED is green
— Filter element is dirty, — Remove Filter element and clean
causing tool to overheat according to Operating Manual.
Use safe cleaning solution
to remove stubborn debris.
— Tool sleeve is dirty
— Clean tool
Returning/Purging Stage of Operation
— Tool operated and
— Built-up dirt and
— Remove debris from Nose bore
drove fastener, but
debris in Nose bore
piston did not return
to start position
— Mushrooming of
— Contact Ramset Distributor
Piston Tip
Sales Representative for service.
— Exhaust ports on the — Return tool to Authorized
Sleeve are dirty
Ramset Distributor Sales
or clogged.
Representative for service.
— Tool sleeve is dirty
— Clean tool
— Tool does not open
— Work Contacting
— Clean tool or replace Work
after tool fires
Element is bent,
Contacting Element as required.
or tool is dirty
If the TF1200 Magazine tool will not operate after following the
above service directions, return the tool to an Ramset
Distributor Sales Representative for service.