Randell RAN FRA-1 Operator's Manual

Other manuals for RAN FRA-1: Reference Manual, Brochure, Specifications, Brochure, Brochure
Manual is about: Randell RAN FRA-1: User Guide

Summary of RAN FRA-1

  • Page 1

    This manual provides information on installation, operating, maintenance, trouble shooting & replacement parts for operators manual notify carrier of damage at once. It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage...

  • Page 2: Table of Contents

    Table of contents page 2 ...................................................................................................... Congratulations page 3 ......................................................................................... Factory correspondence page 3 ................................

  • Page 3: And Parts Hotline

    Notice: due to a continuous program of product improvement, randell man- ufacturing reserves the right to make changes in design and specifications with- out prior notice. Notice: please read the entire manual carefully before installation. If certain recommended procedures are not followed, warrant...

  • Page 4: Warranty Policies

    Parts warranty labor coverage five year extended compressor warranty randell warrants all component parts of manufactured new equipment to be free of de- fects in material or workmanship, and that the equipment meets or exceeds reasonable industry standards of performance for a period of one year fr...

  • Page 5

    Warranty policies (continued) our export warranties will cover all non electrical parts for the period of one year from the date of shipment to be free of defects in material or workmanship. Electrical parts are also covered if ordered and operated on 60 hz. Electrical components, ordered and oper- ...

  • Page 6: Frequently Asked Questions:

    Frequently asked questions: 1. Do you offer 14 g ss models? Answer: yes 2. Is it possible to plug in one unit to run my entire line? Answer: yes, we offer an electrical distribution system vs a duct system. With the randell electrical distribution system (eds), you can bank several units together so...

  • Page 7: Section 1

    Randell refrigerated equipment section 1 unit specifications for: the randell fra ranserve series 7 fra series storage gallon model ld h cu.Ft. Capacity h.P. Volts amps nemashipwt. Ranfra-1 24"27"35" 1.8 6 1/3115/60/1 6.3 5-15p 200 ranfra-2 36"27"35" 3.6 12 1/3115/60/1 6.3 5-15p 230 ranfgfra-1 26"30...

  • Page 8

    Unit specifications for: the randell sca series ran sca series 12"x20"pancoldpan model ld h capacity interiordimensionshpvoltsampsnemashipwt. Ransca-236"30"35" 2 261/4"x21"x83/4"1/4115/60/155-15p250 ransca-348"30"35" 3 391/8"x21"x83/4"1/4115/60/155-15p300 ransca-460"30"35" 4 521/16"x21"x83/4"1/4115/...

  • Page 9

    12"x20"pancoldpan model ld h capacity interiordimensionshpvoltsampsnemashipwt. Ransca-236"30"35" 2 261/4"x21"x83/4"1/4115/60/155-15p250 ransca-348"30"35" 3 391/8"x21"x83/4"1/4115/60/155-15p300 ransca-460"30"35" 4 521/16"x21"x83/4"1/4115/60/155-15p350 ransca-572"30"35" 5 6415/16"x21"x83/4"1/4115/60/1...

  • Page 10

    12"x20"pancoldpan model ld h capacity interiordimensionsshipwt. Ranic-2 36"30"35" 2 25"x20"x6"140 ranic-3 48"30"35" 3 38"x20"x6"175 ranic-4 60"30"35" 4 52"x20"x6"215 ranic-5 78"30"35" 5 67"x20"x6"260 ranic-6 86"30"35" 6 76.5"x20"x6"310 openbase ranic-2s 36"30"35" 2 25"x20"x6"140 ranic-3s 48"30"35" 3...

  • Page 11: Unit Installation

    12"x20"pancoldpan model ld h capacity interiordimensionsshipwt. Ranic-2 36"30"35" 2 25"x20"x6"140 ranic-3 48"30"35" 3 38"x20"x6"175 ranic-4 60"30"35" 4 52"x20"x6"215 ranic-5 78"30"35" 5 67"x20"x6"260 ranic-6 86"30"35" 6 76.5"x20"x6"310 openbase ranic-2s 36"30"35" 2 25"x20"x6"140 ranic-3s 48"30"35" 3...

  • Page 12: Unit Installation

    12 c. Electrical supply d. Installation checklist the wiring should be done by a qualified electrician in accordance with local electrical codes. A properly wired, and grounded outlet will assure proper operation. Please consult the data plate attached to the compressor to ascertain the correct elec...

  • Page 13: Unit Operation

    13 randell has attempted to preset the cold control to ensure that your unit runs at an opti- mum temperature, but due to varying ambient conditions, including elevation, food prod- uct as well as type of operation you may need to alter this temperature. Additional adjust- ments can be made (within ...

  • Page 14: Preventive Maintenance

    14 caution: do not use abrasive cleaning solvents, never use hydrochloric acid (muriatic acid) on stainless steel proper maintenance of equipment is the ultimate necessity in preventing costly repairs. By evaluating each unit on a regular schedule you can often catch and repair minor problems before...

  • Page 15: Easy to Follow

    15 easy to follow trouble shooting chart symptom possible cause procedure unit doesn’t run 1. No power to unit. 2. Temperature control turned off. 3. Temperature control faulty 4. Compressor overheated. 5. Condenser fan faulty 6. Overload protector faulty. 7. Compressor relay faulty. 8. Compressor f...

  • Page 16: Randell Refrigerated Units

    16 randell refrigerated units replacement parts list item description part # cold pan frost top freezer ic unit caster set 001450 x x x x 4 non locking caster hd cst3050 x x x x 5 locking caster hd cst3051 x x x x 7 stainless steel panel, specify dimensions rp pnl001 x x x x 17 power cord el wir461 ...

  • Page 17: Randell Ranserve

    17 randell ranserve hot food equipment section 2 unit specifications for: the randell htd series ran htd shown randell.Com.

  • Page 18

    18 htd series enclosedbase no.Of no.Of 120v 208v 240vship modelsldh wells elements kwamps*nemakwamps*nemakwamps*nema wt. Ranhtd-230"27"35"2 2 2.218.45-30p2.210.66-15p2.29.26-15p 175 ranhtd-348"27"35"3 3 3.327.65-50p3.315.96-20p3.313.86-20p 215 ranhtd-460"27"35"4 4 4.436.85-50p4.421.26-30p4.418.46-30...

  • Page 19: Unit Installation

    Enclosedbase no.Of no.Of 120v 208v 240vship modelsldh wells elements kwamps*nemakwamps*nemakwamps*nema wt. Ranhtd-230"27"35"2 2 2.218.45-30p2.210.66-15p2.29.26-15p 175 ranhtd-348"27"35"3 3 3.327.65-50p3.315.96-20p3.313.86-20p 215 ranhtd-460"27"35"4 4 4.436.85-50p4.421.26-30p4.418.46-30p 260 ranhtd-5...

  • Page 20: Unit Operation

    20 all units are designed for 145 to 175º operation or 140 to 170º product temperature. When using the unit dry expect at least a 15º drop in product temperatures compared to using it wet. Hot food tables may be operated utilizing water or dry. However wet opera- tion is usually recommended for high...

  • Page 21: Easy to Follow

    21 problem possible cause remedy unit will not heat. 1. Thermostat off. 2. Unit unplugged. 3. Circuit breaker tripped. 4. Thermostat defective. 5. Unknown 1. Turn on thermostat. 2. Plug in unit. 3. Reset or replace circuit breaker. 4. Test and/or replace thermostat see fig. 1. 5. Call 888-994-7636 f...

  • Page 22: Randell Ranserve

    22 replacement parts list randell ranserve hot food units item description part # 3 caster set 001450 4 non locking caster hd cst3050 5 locking caster hd cst3051 7 stainless steel panel, specify dimensions rp pnl001 17 power cord w/plug speify voltage & wattage el wirspc 40 door right hand rp dorhtd...

  • Page 23: Randell Mobile

    Item description part # 3 caster set 001450 4 non locking caster hd cst3050 5 locking caster hd cst3051 7 stainless steel panel, specify dimensions rp pnl001 17 power cord w/plug speify voltage & wattage el wirspc 40 door right hand rp dorhtdr 41 door left hand rp dorhtdl 44 gasket, 15” x 15 3/8” in...

  • Page 24: Randell Serving Equipment

    888-994-7636 24 replacement parts list randell serving equipment item description part # cashier stand counter protector s/s work top unit tray & silverware stand 3 caster set 001450 x x x 4 non locking caster hd cst3051 x x x 5 locking caster hd cst3050 x x x 7 stainless steel panel, specify dimens...