Manual is about: Automatic on-off control for up to 10 sections
of
12
Manual # 016-0171-014
7
C
H A P T E R
S
Y S T E M
T
R O U B L E S H O O T I N G
The CAN AccuBoom node (P/N 063-0172-316) has additional features to
allow the user to diagnose the AccuBoom system. The CAN AccuBoom
node has a plastic window in the case that allows the user to view green
diagnostic lights. The picture below shows the positioning of the lights.
•
Logic Power:
Lit when 12VDC logic power is available at the node.
•
Micro 1 Hz:
Flashes at 1 Hz interval when processor is active.
•
CAN Rx:
Flashes when CAN messages are being received.
•
CAN Tx:
Flashes when CAN messages are being transmitted.
•
High Current Power:
Lit when High Current Power is applied to the node.
Logic Power
Micro 1 Hz
CAN Rx
CAN Tx
High Current
Power (HC)