SADiE LRX2 User Manual - page 6
6
MADI
ANALOGUE LEVEL JUMPERS
On the Analogue Line Input and Output slithers, the operating level can be chosen, for each Input and Output
individually if required, by changing the setting of some jumpers.
With the card components-up, 2 x 25way connectors and face plate to the right, just to the left of the
connectors, you will see a vertical line of sixteen three-way headers - one for each Input or Output.
There are three possible ways of connecting these jumpers to change the operating level. This is noted in the
legend on the slither card
+24DBU
No connection
+21DBU
Jumper to the left
+18DBU
Jumper to the right (FACTORY DEFAULT)
Note that single-ended connection is not advisable for inputs or outputs that are set to +21dBu or
+24dBu. Factory default is +18dBu.