Also pay attention to the following
The stove is suitable for a chimney with several shafts. For this purpose,
the stove must be used with closed doors.
There must be an adequate air supply. Tightly closed doors and windows
may cause problems in this regard.
Preferably place your stove near the chimney (hearth). A heat-resistant,
fireproof base (bottom plate) must be placed underneath the stove.
These bases (made of cast iron, steel sheeting…) are available
commercially.
In any case, ensure that the base is fireproof.
Flammable objects such as doors, furniture, woodwork etc. must be at a
distance of at least 60 cm. Place your appliance at least 30 cm away from
the wall. The wall must consist of non-flammable material.
3. CONNECTING THE STOVE TO THE CHIMNEY
The chimney draught must be above 0,08 mbar (0,8 mm WK). The
diameter of the smoke duct must correspond with that of the connector
(150 mm).
The smoke duct must be sealed at all connection points! Attention is
specifically drawn to the danger of escaping fumes.
False air results in a weaker chimney draught.
If the chimney draught is too strong, the installation of a draught
regulator is recommended.
3.1 Saey 200 + :
Top vent
Normally the discharge of fumes takes place at the
back. Another option is to install the smoke duct at
the top.