Saint ST 2004 User Manual - 45 Seconds Re - Arming
SAINT
6
45 Seconds Re - Arming
If your remote mobile security system has become triggered, the horn/siren will sound for 45
seconds and then stop and reset to a fully armed condition.
NOTE: If a protected entrance is left open, your SAINT will remain triggered for two more 45
seconds cycles then fully re-arm excluding the door input trigger. (Door input trigger is
no longer functional) Closing the entrance will reset the door input trigger within 7
seconds.
Secondary RF Protection Mode
Every time you disarm your SAINT with your transmitter, the security system will start an RF
protection mode countdown. This is a timed secondary protection mode to insure that the radio
signal used to disarm the security system was from your transmitter. After the system is disarmed
by radio signal, it will count down for 45 seconds and then become re-armed if no one enters the
vehicle.
NOTE : The feature is only active when the automatic arming feature of the SAINT has been
programmed on.
Alarm Mode Indicators
1. The LED indicator will provide information on 6 modes of security system
operation.
LED is off = Security system is disarmed.
LED is flashing = Security system is armed.
LED is flashing fast = Auto arm timer or RF protection mode timer is counting down.
LED is continuously on = Security system is in valet mode.
LED is flashing in a 2 flash pause sequence = Tamper warning, security system has been
triggered from the hood/trunk switch or
electronic sensor.
LED is flashing in a 3 flash pause sequence = Tamper warning, security system has been
triggered from an opened door.
2. The siren will provide information on 3 modes of security system operation.
One siren chirp = Security system is armed.
Two siren chirps = Security system is disarmed.
Four siren chirps = Tamper warning + security system is disarmed.