Samlexpower G4-2012A Owner's Manual - Section 10 |
SAMLEX AMERICA INC. | 67
SECTION 10 |
Specifications
Inverter Section
Parameter
G4-2012A
G4-2524A
G4-3524A
AC oUTPUT SIDe In InVeRTeR MoDe
Nominal Output voltage
120 vAC
Output voltage Regulation
± 10% RMS (Before Low Battery Alarm)
Nominal Output Frequency
60 / 50 Hz ± 0.3Hz (Auto sensing based on AC input frequency. Default is 60 Hz)
Output voltage Waveform
Pure Sine Wave
Total Harmonic Distortion (Fully
Linear Load)
< 6% (Before Low DC Input
voltage Alarm)
< 3% (Before Low DC Input
voltage Alarm)
<5% (Before Low DC Input
voltage Alarm)
Max. Continuous Output Power
and Current
2000 vA / 16.7A
2500 vA / 20.8A
3500 vA / 29.0A
300% Surge Output Power and
Current for 1ms
6000 vA / 50.0A
7500 vA / 62.4A
10,500 vA / 87.0A
200% Surge Output Power and
Current for 100 ms
4000 vA / 33.4A
5000 vA / 41.6A
7000 vA / 58.0A
150% Overload Limit, 20 sec
3000 vA / 25A
3750 vA / 31.3A
5250 vA / 43.8A
130% Overload Limit, 60 sec
2600 vA / 21.7A
3250 vA / 27.1A
4550 vA / 37.9A
110% Overload Limit, 15 min
(Started in cold condition)
2200 vA / 18.3A
2750 vA / 22.9A
3850 vA / 32.1A
Load Crest Factor
3
3
3
Nominal Efficiency (Peak)
82%
86%
86%
Output Short Circuit Protection
(Shut Down)
•
By voltage detection (< 60 vAC at 1.5th cycle or < 90 vAC at 5.5th cycle) over a period of 10 sec.
•
Auto reset if short circuit condition lasts for < 10 sec. Manual reset thereafter
DC InPUT SIDe In InVeRTeR MoDe
Nominal DC Input voltage
12v (10 to 16.8v ± 0.3v)
24v (20 to 33.6v ± 0.6v)
24v (20 to 33.6v ± 0.6v)
DC Input voltage Range (Before
Low DC Input voltage Alarm)
> 11 ± 0.3v
< (v-Boost + 0.8 ) ± 0.3v
> 22 ± 0.6 vDC
< (v-Boost + 1.6 ) ± 0.6 vDC
> 22 ± 0.6 vDC
< (v-Boost + 1.6 ) ± 0.6 vDC
Minimum DC voltage to Start
>10v
>20v
>20v
Maximum DC Input Current at
Continuous Rated AC Output
250A @ 10v
150A @ 20v
215A @ 20v
Maximum DC Input Current during
300% Surge for 1 msec
875A
525A
752A
Maximum DC Input Current during
200% Surge for 100 msec
750A @ 10v
450A @ 20v
645A @ 20v
Maximum DC Input Current during
150% Overload for 20 sec
500A @ 10v
300A @ 20v
450A @ 20v
Maximum DC Input Current at
130% Overload for 60 sec
375A @ 10v
225A @ 20v
322A @ 20v
Maximum DC Input Current at
110% Overload for 15 min
312A @ 10v
188A @ 20v
268A @ 20v
Maximum allowable External DC
Fuse Rating
350A / 32v
200A / 32v
300A / 32v
Low DC Input voltage Alarm
11.0 vDC ± 0.3 vDC
22.0 vDC ± 0.6 vDC
22.0 vDC ± 0.6 vDC
Low DC Input voltage Shut-down
10.0 vDC ± 0.3 vDC
20.0 vDC ± 0.6 vDC
20.0 vDC ± 0.6 vDC