Samlexpower G4-2012A Owner's Manual - Section 2 |
8 | SAMLEX AMERICA INC.
AC SIDE LAYOUT
0
9 - AC Input, Hot/Line
10 - AC Input, Neutral
11 - AC Input, Ground
12 - AC Output, Ground
13 - AC Output, Neutral
14 - AC Output, Hot/Line
15 - AC Breaker “Charger”:
For Protection in Utility/
Generator Modes
16 - AC Breaker “Load”:
For Protection in Inverter
and Utility/Generator Modes
10 11
12 13 14
9
15
16
Fig. 2.2: AC SIDE LAyOUT & CONNECTIONS
SECTION 2 |
layout of G4 Series
1
6
5
8
7
3
4
2
Fig. 2.3:
LCD
CONTROL
PANEL
9 - Cable for Remote Operation
DC SIDE LAYOUT
1 - Battery Positive (+) Input Connector
2 - Battery Negative (-) Input Connector
3 - External Charger (+) Input Connector
4 - External Charger (-) Input Connector
5 - DC Side Equipment Grounding
Connector
6 - 6P2C Modular Connector for
Temperature Sensor
7 - 8P8C Modular Connector for Remote
8 - Cooling Fan 1 (sucks air from outside
and discharges inside)
Note: Cooling Fan 2 is inside the unit
and is not visible.
2
3
8
4
5
6
7
1
Fig. 2.1: DC SIDE LAyOUT & CONNECTIONS
Protection Covers
for Battery Terminals
2a. BLACK
1a. RED
17 - AC Terminal
Protection Cover
Fig. 2.4 Battery Temperature
Sensor Model BTS-G4
DC SIDe LAYoUT (FIG 2.1)
1. Battery Positive (+) Input Connector –
M8 Nut & Bolt (RED Protection Cover is Removed).
1a. RED Protection Cover For Battery Positive (+)
Input Connector
2 Battery Negative (-) Input Connector –
M8 Nut & Bolt (Black Protection Cover is Removed)
2a. BLACK Protection Cover for Battery Negative (-)
Input Connector
3 External Charger (+) Input Connector –
M8 Thumb Nut and Bolt
4 External Charger (-) Input Connector -
M8 Thumb Nut and Bolt
5 DC Side Ground Connector – Wire Size AWG #4-6.
Set Screw 5/16” – 24 UNF
6 6P2C Modular Connector for
Temperature Sensor "BTS-G4" (Fig. 2.4)
7 8P8C Modular Connector for Remote Operation of
Detachable LCD Control Panel
8 Cooling Fan 1 (Cooling Fan 2 is inside the unit and is
not visible) Note: Cooling Fan 1 sucks cool air from
outside and discharges into the unit.
aC side layOut (Fig. 2.2)
nOte: layout in Fig. 2.2 is shown without the
aC terminal Cover (17).
•
Size of terminal slot for wire entry: 6 x 4.5 mm
•
Wire size accepted by the terminal hole: AWG #6 – 20
9. HOT IN - AC Input , Hot / Line
10. NEU IN - AC Input Neutral
11. GND IN - AC Input Ground
12. GND OUT - AC Output Ground
13. NEU OUT - AC Out, Neutral
14. HOT OUT - AC Out, Hot / Line
15. AC Breaker Marked "Charger"
16. AC breaker Marked "Load"
17. Protection Cover for AC Terminal Pocket
detaCHaBle lCd COntrOl
Panel (Fig. 2.3)
1. LCD Screen - 2 rows of 16 characters each
2. ON/OFF Push Button
3. Green LED - Status
4. Red LED - Fault
5. Key - Set
6. Key - Up
7. Key - Down
8. Key - Enter
9. 10M, RJ-45 Data Cable with 8P8C Modular
Connectors (Straight Wired) for Remote
Operation of Detachable LCD Control Panel
REMOVABLE
TOP COVER
PLATE
KNOCK-OUT
(27.8 MM /
1
3/32
” DIA.)
for 3/4”
Conduit/Fitting