Samlexpower G4-2012A Owner's Manual - Section 10 |
SAMLEX AMERICA INC. | 69
SECTION 10 |
Specifications
Parameter
g4-2012a
g4-2524a
g4-3524a
bATTeRY CHARGeR SeCTIon (ConTInUeD)
Equalization Current
Automatic - 0.5 times the set value of Bulk Charge Current
Equalization Time
Automatic - based on the time the battery remains in Bulk Stage
Maximum Charging Efficiency
70% at charging current = 45A
80% at charging current = 20A
80% at charging current = 20A
Battery Initial voltage
9 to 16 vDC
18 to 32 vDC
18 to 32 vDC
Over Charge Current Protection
95A (Shut down charging)
85A (Shut down charging)
85A (Shut down charging)
Battery Charging voltage Temperature
Compensation (with external Battery
Temperature Sensor Model BTS-G4)
•
Compensation is effective over temperature range of - 20°C to + 50°C
•
Programmable Coefficient of Compensation: -3 to - 5 m v / °C / cell
•
Default: - 4 mv / °C / cell Reference: 25°C
External DC Fuse Protection (Max.)
320A
195A
290A
Over voltage Protection and Alarm
> Programmed Boost voltage
> Programmed Equalization voltage
•
Charger off
•
Green LED - OFF; Red LED - ON
•
1 beep @ 0.5 sec
> Programmed Boost voltage
+ 0.8v for 30 sec
> Programmed Equalization
voltage + 0.6v for 30 sec
•
Charger off. Transfer to
Inverter Mode
•
Green LED OFF; Red LED
blinks
•
3 beeps @ 5 sec
> Programmed Boost voltage
+ 1.6 v for 30 sec
> Programmed Equalization
voltage + 1.2 v for 30 sec
•
Charger off. Transfer to
Inverter Mode
•
Green LED OFF; Red LED
blinks
•
3 beeps @ 5 sec
> Programmed Boost voltage
+ 1.6 v for 30 sec
> Programmed Equalization
voltage + 1.2 v for 30 sec
•
Charger off. Transfer to
Inverter Mode
•
Green LED OFF; Red LED
blinks
•
3 beeps @ 5 sec
Parallel operation with external charger
yes. The total charging current will follow the programmed Bulk Current setting.
Charging voltage range with external
charger
13 to 16 vDC
26 to 32 vDC
26 to 32 vDC
Maximum charging current with
external charger
50A
50A
50A
General
Parameter
g4-2012a
g42524a
g4-3524a
Safety Compliance
•
Intertek-ETL listed: Conforms to ANSI / UL STD. 1741
•
Intertek-ETL listed: Certified to CAN / CSA STD. C22.2 No. 107.1-01
•
Intertek-ETL listed: Conforms to ANSI / UL STD. 458
EMI / EMC Compliance
•
Certified to FCC Part 15(B), Class A
•
Certified to ISO 7637-2 for immunity against conducted electrical transients in vehicles
Operating Temperature Range
0°C to +50°C / 32°F to 120°F
Storage Temperature
-15° C to +60°C / 5°F to 140°F
Operating Humidity
5% to 95%
Audible Noise
Maximum 65 dBA from distance of 1 meter
Earthing
External Earth Ground terminal for connecting the Equipment Grounding Conductor
Dimensions (W x D x H) millimeters
Dimensions (W x D x H) inches
218 x 558 x 198 mm
8.6” x 22” x 7.8”
Weight (kg., Lb)
24.1 Kg, 53.0 lb.
24.6 Kg, 54.1 lb.