Samlexpower PSE-12125A Owner's manual - Section 6 |
22 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 23
terminal of battery 3 is connected to the Positive terminal of battery 2. The negative ter-
minal of battery 2 is connected to the Positive terminal of battery 1. The negative
terminal of battery 1 becomes the negative terminal of the 24V battery bank.
Parallel connection
Fig 6.3: Parallel Connection
when two or more batteries are connected in parallel, their voltage remains the same
but their Ah capacities add up. fig. 6.3 above shows 4 pieces of 12V, 100 Ah batteries
connected in parallel to form a battery bank of 12V with a capacity of 400 Ah. The four
Positive terminals of batteries 1 to 4 are paralleled (connected together) and this com-
mon Positive connection becomes the Positive terminal of the 12V bank. Similarly, the
four negative terminals of batteries 1 to 4 are paralleled (connected together) and this
common negative connection becomes the negative terminal of the 12V battery bank.
Series – Parallel connection
Fig. 6.4: Series-Parallel Connection
figure 6.4 above shows a series – parallel connection consisting of four 6V, 200 Ah bat-
teries to form a 12V, 400 Ah battery bank. Two 6V, 200 Ah batteries, batteries 1 and 2
are connected in series to form a 12V, 200 Ah battery (String 1). Similarly, two 6V, 200 Ah
batteries, batteries 3 and 4 are connected in series to form a 12V, 200 Ah battery
(String 2). These two 12V, 200 Ah Strings 1 and 2 are connected in parallel to form a
12V, 400 Ah bank.
12V
12V
12V
12V
Battery 1
Battery 3
Battery 2
Battery 4
Cable “A”
Cable “B”
12V Inverter
or 12V Charger
6V
6V
6V
6V
12V String 1
12V String 2
Battery 1
Battery 3
Battery 2
Battery 4
12V Inverter
or 12V Charger
Cable “A”