Samlexpower PST-15S-12E Owner's manual - Section 12 |
50 | SAMLEX AMERICA INC.
seCtIOn 12 |
specifications
noteS:
1. All power ratings are specified for resistive load at Power Factor = 1.
2. All specifications given above are at ambient temperature of 25
°
C / 77
°
F.
3. Specifications are subject to change without notice
MoDeL no.
PSt-300S-12e
PSt-300S-24e
oUtPUt
OUTPUT VOLTAGE
230 VAC ± 3%
230 VAC ± 3%
MAXIMUM oUTPUT CUrrENT
13.04A
13.04A
OUTPUT fREQUENCY
50/60 Hz ± 1% : Switch Selectable (Default 50 Hz)
TYPE Of OUTPUT WAVEfORM
Pure Sine Wave
Pure Sine Wave
TOTAL HARMONIC DISTORTION
of oUTPUT WAVEforM
CoNTINUoUS oUTPUT PoWEr
(At Power factor = 1)
3000 Watts
3000 Watts
SUrGE oUTPUT PoWEr
6000 Watts (
6000 Watts (
PEAK EffICIENCY
> 88% (At full load)
> 90% ((At full load)
AC oUTPUT CoNNECTIoNS
(i) European "Schuko", CEE 7/3 AC Receptacle
(ii) Terminal block for hardwiring
inPUt
NOMINAL DC INPUT VOLTAGE
12V
24V
DC INPUT VOLTAGE RANGE
10.7 - 16.5 VDC
21.4 - 33 VDC
MAXIMUM INPUT CUrrENT
420A
240A
DC INPUT CURRENT AT NO LOAD
DC INPUT CONNECTIONS
Bolt & Nut: 5/16” x 18 TPI
Bolt & Nut: 5/16” x 18 TPI
DC INPUT fUSES (INTERNAL)
12 X 35A = 420A (Each Type
ATC, 32V, 35A)
12 x 20A = 240A (Each Type ATC,
32V, 20A)
DiSPLAY
LED
Power, overload, over Temperature
Power, overload, over Temperature
PRotectionS
LOW DC INPUT VOLTAGE ALARM
10.7V ± 0.1V
21.4V ± 0.2V
LOW DC INPUT VOLTAGE SHUTDOWN
10V ± 0.1V ; Auto-reset: 11.5V ± 0.3V
20V ± 0.2V ; Auto-reset: 23V ± 0.5V
HIGH DC INPUT VOLTAGE
SHUTDOWN
16.5V ; Auto-reset:
33V ; Auto-reset:
SHORT CIRCUIT SHUTDOWN
When output voltage drops to 170VAC or lower for 1 to 1.5 sec
OVERLOAD SHUTDOWN
At overload of 110% to 115% for 2 to 2.5 sec
OVER TEMPERATURE SHUTDOWN
90°C ± 5°C (Sensed at Transformer T3) ; Auto reset at 65°C ± 5°C
REVERSE POLARITY ON
DC INPUT SIDE
External / internal DC sides fuses will blow
ReMote contRoL
WIRED REMOTE CONTROL WITH
LED / LED DISPLAY
WIRED ON / Off CONTROL
RC-300 (sold separately) with 25’ cable
(i) By switching external contact (ii) By switching external 12V/24V signal
cooLinG
fORCED AIR COOLING
Temperature controlled fan (Sensed at Transformer T6)
fan ON at 55°C ± 3°C; fan Off at 45°C ± 3°C
coMPLiAnce
EUROPEAN CONfORMITY
CE marked
SAfETY
European Low Voltage Directive 2014/35/EU
• Standard : EN 60950-1
EMC
European EMC Directive 2014/30/EU per following Standards:
• EMI: EN55022, Class A ; EN61000-3-2, -3-3
• EMS: EN55024; EN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11
enViRonMent
WorKING ENVIroNMENT
Indoor use
oPErATING TEMPErATUrE rANGE
-20˚C to 40˚C / -4˚f to 104˚f
-20˚C to 40˚C / -4˚f to 104˚f
RELATIVE HUMIDITY
Up to 85%, non condensing
DiMenSionS
(W X D X H), MM
263 x 456.5 x 145
263 x 456.5 x 145
(W X D X H), INCHES
10.35 x 17.97 x 5.71
10.35 x 17.97 x 5.71
WeiGHt
KG
9.8
9.8
LBS
21.6
21.6