Samlexpower SEC-1250UL Owner's Manual - Section 7 |
20 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 21
seCtIOn 7 |
Preparing the Charger for Operation
-Stage1andStage3.Thisalsoapplieswhentwobanksofbatteriesarebeingcharged
simultaneouslyandthebatteriesinthetwobanksareinadissimilarstateofdischarge.
ApairofswitchesS1&S2outofasetof4DIPSwitcheshasbeenprovidedforselecting
thebatterytypeandformodifyingtheStage2AbsorptionStagewhenchargingloaded
batteries/twobanksofbatterieswithdifferentdischargedstates.Thefollowingselec-
tions can be made with the help of the DIP Switches S1 and S2:
!
cAUtion!
DonotchangetheDIPSwitchsettingwhenthechargerisoperating.Always
changetheDIPSwitchsettingwhenthechargerisOFF,i.e.afterdisconnecting
thechargerfromtheACinputpower).
note:Thevoltagesareforbatterytemperatureof77ºF/25ºC.
diP SWitcH SettinG FoR Sec-1250Ul
S1
S2
Float
Absorption
Battery
type
charging
Stages
off*
ON*
13.5V*
14.4V*
Flooded/
AGM*
3 Stages
(Stages1,2,3)
ON
off
13.5V
14.0V
GelCell
3 Stages
(Stages1,2,3)
off
off
13.5V
Disabled
battery with
Load
2 Stages
(Stages1,3)
ON
ON
caution! do not use this setting
* factory pre-set in this position
diP SWitcH SettinGS - Sec-2425Ul
S1
S2
Float
Absorption
Battery type
charging
Stages
off*
ON*
27V*
28.8V*
Flooded/
AGM*
3 Stages
(Stages1,2,3)
ON
off
27V
28.0V
GelCell
3 Stages
(Stages1,2,3)
off
off
27V
Disabled
battery with
load
2 Stages
(Stages1,3)
ON
ON
caution! do not use this setting
* factory pre-set in this position