Samlexpower SI-A1-VR1500 Owner's Manual - page 6
INSTALLATION NOTES:
WARNING: Keeping ventilation when using batteries. Batteries may generate
flammable gas during charging or discharging.
The inverter has four slots in its mounting bracket that allow the unit to be
fastened against a bulkhead, floor, wall or other flat surface. Ideally, the
mounting surface should be cool to the touch.
It is more electrically efficient to use longer AC wiring than DC wiring, so
install the inverter as close as possible to the 12 VDC power source.
The inverter can be operated in any position, however, if it is to be mounted on a
wall, mount it horizontally so that indicators, switches, outlets and terminal
blocks located on the front panel are visible and accessible. If inverter is to be
installed in a moving vehicle, we strongly recommends that the inverter be
shock-mounted either on the floor (in a clear, safe area) or on a secure flat
surface.
CAUTION: The inverter must be connected only to batteries with a nominal
output voltage of 12volts. The unit will not operate from a 6 volt battery, and will
sustain permanent damage if connected to a 24 volt battery.
CAUTION: Loose connectors may cause overheated wires and melted
insulation. Check to make sure you have not reversed the polarity.
Reverse polarity connection will result in a blown fuse and may cause
permanent damage to the inverter.
CONNECTING TO A POWER SOURCE
Use ( #2 AWG for VR1500; 2x #2 AWG for VR2000/3000) wire for if the
inverter to power source connection is 1.5 meters or less. For longer cable
lengths, consult technician for appropriate cable size. In either case,
protect the positive (+) wire from shorts by installing a fuse or circuit
breaker close to the DC power source (battery) terminal. The fuse should
choose 200A for VR1500, 300A for VR2000, 400A for VR3000.
1. Check to be sure the inverter’s power switch is turned off and that no
flammable fumes are present.
2. Identify the positive (+) and negative (-) DC power source (battery)
terminals.
3. Install a fuse holder or breaker close to the positive (+) terminal of the
DC source (battery).
4. Connect a length of wire on one side of the fuse holder or circuit
breaker. Connect the other end if the wire to the positive (+) terminal of
the inverter.
6