Samlexpower SI-A1-VR1500 Owner's Manual - Caution:
5. Connect a length of wire between the inverter’s negative (-) terminal
and the DC power source negative (-) terminal.
6. Connect
a
short
length
of wire to the other terminal of the fuse holder
or circuit breaker. Mark it “POSITIVE” or “+”.
7. Connect the free end of the fuse or breaker wire to the positive terminal
of the DC power source (battery).
8. Insert a suitable fuse in the fuse holder.
9. Check to be sure that all connections between battery clips, terminals
and fuse are secure and tight.
10. Test the inverter by turning it on and plugging in a 100 watt lamp or
equipment.
11. If the inverter is not properly operating, then refer to the
troubleshooting sections of this manual.
CAUTION:
Loose connectors may cause overheated wires and
melted insulation.
CONNECTION TO LOAD
The inverter is equipped with two universal AC power receptacles. Plug the
cord from the equipment you wish to operate into the AC receptacle. The
green LED indicator lights to indicate that the inverter is functioning. Make sure
the combined load requirement of your equipment does not exceed inverter’s
output rating.
The inverter is engineered to be connected directly to standard electrical and
electronic equipment in the manner described above. Do not connect the
power inverter to household or RV AC distribution wiring. Do not connect the
power inverter to any AC load circuit in which the neutral conductor is
connected to ground (earth) or to the negative of the DC (battery) source.
WARNING: Do not connect to AC distribution wiring.
7