Samlexpower SMC-20 Owner's Manual - Section 3 |
10 | SAMLEX AMERICA INC.
SECTION 3 |
Installation
-
First connect the L+ load cable to the correct pole of the right pair
of terminals on the solar charge controller (with the lamp symbol),
then connect the L– cable.
-
Replace the load fuse or switch on the load.
4TH STEP: FINAL WORK
Fasten all cables with strain relief in the direct vicinity of the solar charge
controller(clearance of approx. 10 cm).
GROUNDING
The components in stand-alone systems do not have to be grounded –
this is not standard practice or may be prohibited by national regulations
(e.g.: DIN 57100 Part 410: Prohibition of grounding protective low voltage
circuits). Consult the technical manual for more information. In case
grounding is mandatory, ground ONLY the Negative Battery Terminal.
LIGHTNING PROTECTION
In systems subjected to an increased risk of overvoltage damage, we
recommend installing additional lightning protection / overvoltage
protection to reduce dropouts. Consult the technical manual for more
detailed information.