Samlexpower SMC-20 Owner's Manual - Section 3 |
SAMLEX AMERICA INC. | 7
SECTION 3 |
Installation
!
WARNING!
Danger of explosion from sparking! Danger of electric shock!
-
The solar charge controller may only be connected to the local loads
and the battery by trained personnel and in accordance with the ap-
plicable regulations.
-
Follow the installation and operating instructions for all components
of the PV system.
-
Ensure that no cables are damaged.
MOUNTING THE SOLAR CHARGE CONTROLLER
Mounting location requirements
-
Do not mount the solar charge controller outdoors or in wet rooms.
-
Do not subject the solar charge controller to direct sunshine or other
sources of heat.
-
Protect the solar charge controller from dirt and moisture.
-
Mount upright on the wall (concrete) on a non-flammable substrate.
-
Maintain a minimum clearance of 10 cm below and around the device
to ensure unhindered air circulation.
-
Mount the solar charge controller as close as possible to the batteries
(with a safety clearance of at least 30 cm).
Fastening the solar charge controller
-
Mark the position of the solar charge controller fastening holes on
the wall.
-
Drill 4 x 6 mm holes and insert dowels.
-
Fasten the solar charge controller to the wall with the cable
openings facing
down- wards, using 4 oval head screws M4 x 40 (DIN 7996).
CONNECTION
Preparing the wiring
The cross section of the connection cable depends on the power output of
the solar charge controller.
CONTROLLER
TYPE
LOAD/MODULE
CURRENT
CROSS-SECTION
AWG
INSULATION
20A
20A
10 mm
2
8
85°C
The table above applies to the following cable lengths:
-
10 m solar module connection cable
-
2 m battery connection cable
-
5 m load connection cable